Multi-position (upflow, downflow, horizontal left, horizontal right) without modifications * 0 Modifiable for side-entry return air . Low-flow, high-head pump custom designed to work with Rinnai's tankless water heaters . Integrated control board with learning algorithm . No combustion air infiltration losses when used with a Rinnai tankless water heater . Four selectable heat blower off delay times . Multi-speed motors (ECM) . Strong 20-gauge steel cabinet 0 Galvanized, painted 0 Fully insulated cabinet 0 Low 34 inch profile . Multi-position control box . Designed for serviceability . Schrader valves to purge . Integral filter rack .Fan motor with * NOTE: The unit is not face down. Part of the Rinnai Tankless Heating System PATENT PENDING AHB60 AHB45 The optimum in hydronic technology, the newly designed Rinnai® multi-position hydronic furnaces offer a unique solution for a wide variety of small- and medium-sized residential and light commercial applications. They are compact and ready to fit in tight spaces which may include, but not limited to, attics, basements, closets, crawlspaces, and utility rooms. Intelligent Microprocessor Controller The 37AHB units are equipped with an intelligent microprocessor control that allows for domestic hot water priority and adapts to available hot water flow for space heating by automatically regulating the pump and fan sequence to maximize comfort. Fine Tuned to Work with Rinnai Tankless Water Heaters These unique hydronic furnaces are designed in combination with our line of Rinnai® heaters to deliver heating capacities spectrum of residential and light applications. When combined, Tankless Heating System, the hydronic heating solution This product is manufactured facility registered by to ISO 9001. UL recognized component 600000060 Equipment CABINET 20 gauge prepainted galvanized steel fully insulated HEAT EXCHANGER copper tube aluminum fin PUMP high-head low-flow integrated check valve BLOWER ASSEMBLY multi-speed motor (ECM) 37AHB Series Hydronic Furnace Accessories THERMOSTATS Programmable, 5-2 days; both A/C and heat pump versions FLOW SENSOR * For domestic hot water priority * Supplied with the unit ANTI-SCALD MIXING VALVE To maintain safe domestic hot water temperature FILTER RACK and BOTTOM FILL PLATES For modification to allow side-entry return airflow Factory available from Rinnai CONTROL BOARD integrated microprocessor based FILTER Optional Equipment Nomenclature Humidifier (HUM) Electronic Air Cleaner (EAC) UV Lamp Cooling Coil Connect an auxiliary 2.5 FLA, 2.5 LRA @ 115 VAC max Humidifier. Connections are made via the “HUM” quick connects. The humidifier output is on whenever a heating demand is being satisfied. The contacts of this output are isolated to allow application of 24 VAC or 115 VAC to one terminal and the humidifier load to the other. Connect an auxiliary Electronic Air Cleaner; rating shall be max 1.0 Amp @ 115 VAC. This output is energized whenever any of the four blower speeds are energized. Connections are made via 0.250 x 0.032” male quick connect terminals labeled "EAC" and "N3". Connect an auxiliary UV lamp (if required); rating shall be max 1.0 Amp @ 115 VAC. This output is energized whenever any of the four blower speeds are energized. Connections are made via 0.250 x 0.032” male quick connect terminals labeled "UV" and "N2". Can accomodate most brands of evaporator A-coil for cooling applications. FIELD-SUPPLIED ACCESSORIES capable of interfacing with the Rinnai Hydronic Furnace: 37AHB Series Hydronic Furnace Heating Capacities 37AH B 045 08 K A 5 Multi-position 5 = Yes 2 = No Engineering Digit Denotes minor change Voltage Code (V-Ph-HZ) K = 115 - 1 - 60 L = 240 - 1 - 50 (export models) Model 37AH - Multi-speed Hydronic Furnace Series A - Unit with PSC Motor B - Unit with ECM Technology Nominal Heating Capacity (BTU/h) 045 = 45,000 060 = 60,000 075 = 75,000 090 = 90,000 Cooling / Heating Air Flow Range (CFM) 08 = 800 (650-800) 12 = 1200 (650-1200) 14 = 1400 (1000-1600) 16 = 1600 (1200-1750) Nominal heating capacities as tested with Rinnai tankless water heaters. For final rated capacities refer to the Air Delivery and Performance Tables in the Operation and Installation Manual. AHB45 (BTU) AHB60 (BTU) AHB75 (BTU) AHB90 (BTU) 120. F 27,700 36,400 43,700 54,900 130. F 33,300 45,100 52,900 63,900 140. F 40,100 50,800 61,600 76,200 150. F 47,700 59,700 70,400 86,600 160. F 51,200 68,100 78,900 96,300 Dimensions Minimum Clearance to Combustible Construction Warranty * In order to receive full warranty coverage on the Hyrdronic Furnace when connected to any other type or brand of product other than a Rinnai tankless water heater, the flow rate through the Hydronic Furnace must not exceed a maximum of 5 GPM. Rinnai will repair or replace the covered product or any part or component that is defective in materials or workmanship as set forth. Rinnai will pay reasonable labor charges associated with the repair or replacement of any such part or...