Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Bryant, modelo 394C

Fabricar: Bryant
Tamaño del archivo: 172.87 kb
Nombre del archivo: pds394c.100.4.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


100.4 8/28/68 AIR OUTLET AIR OUTLET AIR OUTLET NOTE: Blower cosing and furnace shipped individually. ^Add 1^" when installed with base on combustible floor. NOTE: Both drawings - *Add 1J4" when installed with base on combustible floor. NOTE: Both drawings - Blower casing and furnace shipped individually. HEATING RATINGS AND CAPACITIES Rating1 Input2 BTUH 100,000 Output BTUH 80,000 1Ratings are for elevations up to 2000 ft.; for higher altitudes, reduce ratings 4% for each 1000 ft. above sea level. 220% reduction in input allowed COMPONENT INFORMATION Motor—Type L—4 Speed Vs HP (Sh. Pole) Power Supply 120-60-1 Full Load Amps 6.3 . Speed & Rotation 1050 CCW* Motor—Type B—4 Speed Vs HP (PSC) Power Supply 120-60-1 Full Load Amps 6.5 Speed & Rotation 1075 CCW* Motor—Type B—1 Speed SF И HP (Split Ph.) 1.35 Power Supply 115-60-1 Full Load Amps 3.2 Speed & Rotation 1725 CW* Motor Pulley Dia. & Bore 2.4" X 14. " Blower Pulley Dia. & Bore 4.8" X Vi" Belt Width & Length Ув" X 35" Motor—Type C—1 Speed SF Vz HP (Split Ph.) 1.35 Power Supply 115-60-1 Full Load Amps 4.65 Speed & Rotation 1725 CW* Motor Pulley Dia. & Bore 2.9" X У.” Blower Pulley Dia. & Bore 5" x H" Belt Width & Length У2" X 36" Motor—Type X—1 Speed SF ^ HP (Split Ph.) 1.35 Power Supply 115-60-1 Full Load Amps 7.0 Speed & Rotation 1725 CW* Motor Pulley Dia. & Bore 2.9" X У2" Blower Pulley Dia. & Bore 4.7" X M " Belt Width & Length- J4" X 35" Blower Wheel Dia. & Width 10 X 8 Bore—Direct Drive У2" Bore—Belt Drive И" Filter—Fiberglass** 10" X 20" X 1" (2) DRIVE TYPES L—Multi-speed direct drive heating—minimum cooling E—Multi-speed direct drive heating—maximum cooling with evaporator blower motor relay B—Belt drive heating—minimum cooling C—Belt drive heating and cooling X—Belt drive heating—maximum cooling CLEARANCES FROM COMBUSTIBLES 1" from casing sides, rear and bottom. 6" from casing front and vent connector. Note: This furnace is approved for installation on a combustible floor when installed with a matching Bryant combustible floor base. STANDARD GAS CONTROL OPTIONS Control Type D2 D4 D5 Gas Propane City City 100% shut-off automatic pilot; Bryant diaphragm valve; transformer. Bryant diaphragm valve; Bryant automatic pilot; gas pressure regulator; transformer. 100% shut-off for natural gas. Same as D4 except uses thermocouple pilot and pilot relay. CONTROL INFORMATION Burners (Steel Slotted Port) 4 Orifice Drill Size—Propane 54 —Natural 41 D2 Control (Prop.) Regulator None Required Valve K A641 Escapement Orifice Drill Size 80 Pilot—MH Q314A .011 Orifice D4 Control (Nat.) Regulator Comb. Thermae Yi VR-1 Valve K A641 Escapement Orifice Drill Size 80 Pilot—732 .016 Orifice D5 Control (Nat.) Regulator Comb. Thermae y2 VR-1 Valve A641 Escapement Orifice Drill Size 80 Pilot—MH Q314A .018 Orifice' *Rotation viewed from end opposite shaft. **Use multi-velocity filters above 1000 CFM. Manual Shut-Off Cock and Pilot Cock are standard equipment. Supplied as separate parts except where included as integral part of the combination regulator. CONNECTIONS Gas Supply NPT—Natural y* —Propane y¡ Electric Supply—Direct Drive 120-60-1 —Belt Drive 115-60-1 Branch Circuit Wire Size AWG 14 Fuse Size AMPS 15 Control Circuit Power Avail. * Type L, B, C, X VA 10.8 Type E VA 7.2 Flue Size Inches 5 (Oval) Duct—Top Inlet Type C D x W 18M x 16M Type CS D x W 20 x 18 Jí Duct—Bottom Discharge From Unit D x W 22 JC x 14M From Combustible Floor Base D x W 21M x 14 ys LINE-TO-LINE SCHEMATIC UNIT WIRING DIAGRAMS ‘External to unit. AIR FLOW FOR INDICATED AIR TEMPERATURE RISE* TEMP RISE °F 70 75 80 85 90 95 100 AIR FLOW CFM 993 926 869 818 772 732 695 *At Rated Input AIR DELIVERY PERFORMANCE Air Delivery CFM EXTERNAL STATIC PRESSURE AVAILABLE Type L Motor Type E Motor Hi Med Med-Lo Lo Hi Med Med-Lo Lo 700 .62 .49 .30 .67 800 .48 .30 .47 ■ 900 .32 .72 1000 .00 .72 .58 1100 .60 .38 1200 .65 .45 .12 1300 .54 .28 1400 .41 .08 1500 .28 1600 .13 Type L Above data gives Cfm under typical field application (i.e. 125 volts). Air Delivery CFM TYPE B MOTOR (H HP) Blower Speed in RPM at Indicated Static Pressure 0.0" 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" 0.8" 700 630 710 775 845 800 600 670 740 815 900 . 645 715 790 850 1000 620 695 765 1100 670 Drive Range 583-863 RPM Air Delivery CFM TYPE C MOTOR {lA HP) Blower Speed in RPM at Indicated Static Pressure o o 0.1" 0.2" 0.3" 0.4" 0.5" 0.6" 0.7" o OQ 700 710 775 845 905 965 800 670 740 .815 875 935 995 900_ 715 790 850 910 965 1000 695 765 830 890 945 1000 1100 670 745 815 875 930 985 1200 725 805 865 920 975 1300 800 860 920 975 1400 ' 855 920 975 Type E Drive Range 665-1000 RPM Air Delivery CFM TYPE X MOTOR (M HP) Blower Speed i...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría