Manual de usuario Bryant, modelo 313AAV

Fabricar: Bryant
Tamaño del archivo: 3.52 mb
Nombre del archivo: 43ac6238-ff8a-4264-9efa-e2f52e52f337.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


3 CODESANDSTANDARDS.......................... 4 Safety ........................................ 4 GeneralInstallation............................... 5 CombustionandVentilationAir ..................... 5 DuctSystems ................................... 5 AcousticalLiningandFibrousGlassDuct ............. 5 GasPipingandGasPipePressureTesting ............. 5 ElectricalConnections ............................ 5 Venting ........................................ 5 ELECTROSTATICDISCHARGE PRECAUTIONS PROCEDURE ..................................... 5 LOCATION ....................................... 6 INSTALLATION .................................. 10 UpflowInstallation .............................. 10 DownflowInstallation ........................... 11 HorizontalInstallation ........................... 13 FilterArrangement .............................. 14 AirDucts ..................................... 14 GasPiping .................................... 17 115- --VWiring.................................. 22 START- --UP,ADJUSTMENT,ANDSAFETYCHECK..... 36 General....................................... 36 Start- --upProcedures ............................. 36 Adjustments ................................... 36 CheckSafetyControls ........................... 39 Checklist...................................... 40 SERVICEANDMAINTENANCEPROCEDURES ....... 43 Introduction ................................... 43 CareandMaintenance ........................... 46 SequenceofOperation ........................... 49 WiringDiagrams ............................... 51 Troubleshooting ................................ 51 ama ISO 9001:2000 REGISTERED CERTIFIED NOTE: Read the entire instruction manual before starting the installation. PortionsofthetextandtablesarereprintedfromNFPA54/ANSI Z223.1- --2006E, with permission of National Fire Protection Association,Quincy,MA02269andAmericanGasAssociation, Washington DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI on the referencedsubject,whichisrepresentedonly bythestandardin itsentirety. (733mm) (664mm) 26-1/8" (FLUE COLLAR) (22mm) 7/8" DIA ACCESSORY 5-1/2" (140mm) 28-7/8" 25-1/4" 22-9/16" JUNCTION BOX LOCATION 1/2" (13 mm) DIA. THERMOSTAT WIRE ENTRY 3-15/16" (84mm) LEFT HAND GAS ENTRY 33-5/16" 24-7/8" 7/8" (22mm) DIA. ACCESSORY 11/16" 21-5/8" BOTTOM INLET 1-11/16" 5-15/16" (135mm) 24" (641mm) (573mm) (846mm) (17mm) (549mm) (43mm) (632mm) A D F E 11/16" (17mm) SIDE INLET (25mm) CASING (610mm) A04037 NOTES: 1. Two additional 7/8---in. (22 mm) diameter holes are located in the top plate. 2. Minimum return---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters. a. For 800 CFM---16---in. (406 mm) round or 14 1/2 x 12---in. (368 x 305 mm) rectangle. b. For 1200 CFM---20---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle. c. For 1600 CFM---22---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle. d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both sideinlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM. Fig. 1 - --Dimensional Drawing 2-7/16" 1-1/8"13/16" 4-13/16" AIRFLOW 19" OUTLET 13/16" 11/16"8-9/16" VENT OUTLET 5 PLACES (TYP) 3-3/4" 1-3/4" DIA.RIGHT HAND GAS ENTRY 7/8" DIA. K.O. WIRE ENTRY 14-7/8" 7/8" DIA. ACCESSORY 1-1/4" 1"22-1/16" 1-5/16" 1/2" DIA. K.O.THERMOSTAT WIRE ENTRY ALTERNAT E JUNCTION BOX LOCATIONS (TYP) 1-1/2" 7-3/4" 9-5/8" 11-1/2" 5-1/2" (140mm) (95mm) (21mm) (122mm) (217mm) (62mm) (33mm) (29mm) (483mm) (13mm) (44mm) (22mm) (22mm) (38mm) (560mm) (32mm) (378mm) (17mm)(197mm)(244mm) (292mm) (21mm) 313A AD CABINET SUPPLY- ---AIR FURNACE SIZE WIDTH WIDTH IN. (MM) IN. (MM) 045- ---08/024045 14- ---3/16 (360) 12- ---9/16 (319) 070- ---16/048070 17- ---1/2 (445) 15- ---7/8 (403) 090- ---16/048090 21 (533) 19- ---3/8 (492) 110- ---20/060110 21 (533) 19- ---3/8 (492) 135- ---20/060135 24- ---1/2 (622) 22- ---7/8 (581) Table 1–Dimensions E RETURN- ---AIR WIDTH IN. (MM) 12- ---11/16 (322) 16(406) 19---1/2(495) 19---1/2(495) 23 (584) FLUECOLLAR* IN.(MM) 4(102) 4(102) 4(102) 4(102) F FILTER C.L. TOP AND MEDIA SHIP WT BOTTOM FLUE CABINET (LB / KG) COLLAR SIZE IN. (MM) IN. (MM) 9- ---5/16 (237) 114 (52) 16 (406) 11- ---9/16 (294) 136 (62) 16 (406) 13- ---5/16 (338) 150 (68) 20 (508) 13- ---5/16 (338) 162 (73) 20 (508) 15- ---1/16 (383) 4 (102) 173 (78) 24 (610) * 5 in. or 6 in. (127 or 152 mm) vent connector may be required in some cases. SAFETY CONSIDERATIONS ! WARNING FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in dangerous operation, serious injury, death, or property damage. Improper installation, adjustment, alteration, service, maintenance, or use could cause carbon mon...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría