Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Bryant, modelo Condensing Oil-Fired Furnace

Fabricar: Bryant
Tamaño del archivo: 4.61 mb
Nombre del archivo: 383b3cea-4e50-48ef-8794-a42c2e44ce0b.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Improper installation. adjustment. alteration or maintenance can cause injury or property damage. Please refer to this manual. For assistance or additional information, contact a qualified installer or service agency. Please leave this manual with the homeowner. TABLE OF CONTENTS TABLE OF CONTENTS I. Component Identification 2 II. Safety 2 III. Product Application ----------4 IV. Location Requirements &Considerations -------4 Clearances and Accessibility -----------------5 Thermostat Location -------6 Existing Furnace Removal ------7 V. Combustion and Ventilation Air Requirements ---6 VI. Vent/Flue Pipe & Combustion Air Pipe ---7 Non-direct/Direct Vent------------------10 Materials and Joining Methods-------------7 Proper Vent/Flue & Combustion Air Piping Practices----------8 Termination Locations------8,9,10,11 Standard Furnace Connections --10,11 Alternate Furnace Connections 10,11 Direct and Non-Direct Vent (Dual Pipe) Piping-------------11 VII. Condensate Drain Lines & Drain Trap --------14 VIII. Electrical Connections--------------------------------12 OM 115 Volt Line Connections---· -----------12 Wiring Diagram -----uu -------------------13 24 Volt Thermostat Wiring ---------14 IX. Oil Supply and Piping --------15 Oil Lines--------16 X. Circulating Air & Filters ------------------------------16 Ductwork -Air Flow --------------16 XI. Startup Procedure & Adjustment ------------------17 Heat Anticipator Setting -------18 Drain Trap Priming-----------17 Operational checks--------------------------17, 18, 19 Oil Pump Pressure Measurement and Adjustment---17 Temperature Rise-----------18 Circulator Blower Speeds ------------18, 19 XII. Normal Sequence of Operation -----------------19 Power Up----------------------19 Heating Mode-.. -------------------19 Fan Only Mode ---------------------19 Cooling Only Mode --19 XIII. Troubleshooting----19 Systems and General 20,21 Diagnostic Chart (see Honeywell primary control attachment) XIV. Maintenance &Annual Inspection------------------------22 Annual Inspection----------------------------------22 Filters------------------------------17 Circulator Blowers --18, 19 Condensate Trap & Drain System 22 XV. Repair &Replacement Parts-----------------------23, 24 ~_-- PART NO. CTVS24AA GH1033 M-3212 M-3212 M-3212 AGH1059 AGH1059 EE8201 DESCRIPTION FAN TIMER TRANSFORMER BLOWER RELAY AlC RELAY BURNER RELAY 24v TERMINAL STRIP 115v TERMINAL STRIP BLOWER MOTOR TERMINAL BLOCK IGNITION TRANSFORMER ----t-....... FUEL PUMP ---t---., A B C D E F G H ITEM LETIER I. Component Identification PRESSURE SWITCH II. SAFETY Please adhere to the following warnings and cautions when installing, adjusting, altering, servicing, or operating the furnace. 1m ortant The following Instruments must be used to adjust the burner on startup. Failure to use the proper instruments will void our warranty and will result in an unsatisfactory instaUation. BacharaCh Electronic Combustion Analyzer Bacharach Smoke Tester (Or equivalent to above) Oil Pressure Gauge ! WARNING TO PREVENT PERSONAL INJURY OR DEATH DUE TO IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE, REFER TO THIS MANUAL. FOR ADDITIONAL ASSISTANCE OR INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE FUEL OIL SUPPLIER. ___--. HIGH LIMIT PRIMARY OIL CONTROL t.---BURNER MOTOR ____--FUEL FILTER HEAD +---+--__ FUEL FILTER CARTRIDGE AUXILIARY UMIT -----MANUAL RESET ----CONDENSATE COLLECTOR ----BLOWER DOOR INTERLOCK SWITCH BLO'JER SECTION Figure 1 ! WARNING HIGH VOLTAGEI TO AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH DUE TO ELECTRICAL SHOCK, THE FURNACE MUST BE LOCATED TO PROTECT THE ELECTRICAL COMPONENTS FROM WATER. ! WARNING DO NOT UTILIZE THE HEATING UNIT WITHOUT REASONABLE ROUTINE INSPECTION, MAINTENANCE AND SUPERVISION. IF THE UNIT IS IN A BUILDING THAT IS OR WILL BE VACANT, CARE SHOULD BE TAKEN TO ROUTINELY INSPECT, MAINTAIN AND MONITOR THE UNIT. IN THE EVENT THAT THE BUILDING MAY BE EXPOSED TO FREEZING TEMPERATURES AND WILL BE VACANT, DRAIN ALL WATERBEARING PIPES, PROPERLY WINTERIZE THE BUILDING AND TURN OFF ALL WATER SOURCES. IN THE EVENT THAT THE BUILDING IS EXPOSED TO FREEZING TEMERATURES AND IS VACANT, ANY HYDRONIC COIL UNITS SHOULD ALSO BE DRAINED AND AN ALTERNATIVE HEAT SOURCE UTILIZED. 2 I WARNING WE WILL NOT BE RESPONSIBLE FOR ANY INJURY OR PROPERTY DAMAGE ARISING FROM IMPROPER SERVICE OR SERVICE PROCEDURES. IF YOU INSTALL OR PERFORM SERVICE ON THIS UNIT, YOU ASSUME RESPONSIBILLITY FOR ANY PERSONAl INJURY OR PROPERTY DAMAGE WHICH MAY RESULT. MANY JURISDICTIONS REQUIRE A LICENSE TO INSTALL OR SERVICE HEATING AND AIR CONDITIONING EQUIPMENT. INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER, SERVICE AGENCY OR FUEL OIL DEALER. DANGER PELIGRO CARBON MONOXIDE POISONING HAZARD To The Installer Before installing this unit, please read this manual thoroughly to familiarize yourself with specific items which must be adhered to, including, but not limited to: unit maximum external static pre...

Otros modelos de este manual:
Eléctrico - Condensing Oil-Fired Furnace (4.61 mb)
Eléctrico - Condensing Oil-Fired Furnace (4.61 mb)
Eléctrico - Condensing Oil-Fired Furnace (4.61 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría