Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario York, modelo PV9

Fabricar: York
Tamaño del archivo: 196.81 kb
Nombre del archivo: b917e178-663c-4f3e-81ca-0638b47d76a4.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


30-7/8 21-1/2 13-7/8 7 11 7/8 7/8 23-3/4 30-1/8 26-1/2 24-5/8 A 40 26-1/2 25-3/8 28-3/8 21-1/2 11 8 26-3/4 1-3/8 1-1/4 C 24-3/8 20 5/8 5/8 B 26-1/2 1-3/4 D 1-1/2” GAS PIPE ENTRY 7/8” JUNCTION BOX HOLE T-STAT WIRING 7/8” K.O. CONDENSATE DRAIN 7/8” K.O. OPTIONAL RETURN AIR CUT-OUT (either side) FOR USE WITH EXTERNAL FILTER FRAME LEFT SIDE FRONT RIGHT SIDE BOTTOM IMAGE RETURN END TOP IMAGE SUPPLY END 1-1/2” GAS PIPE ENTRY 7/8” JUNCTION BOX HOLE T-STAT WIRING 7/8” K.O. CONDENSATE DRAIN 7/8” K.O. DIMENSIONS Models CFM Cabinet Size Cabinet Dimension Air Intake A (in.) B (in.) C (in.) D (in.) PV9A12N040UP11 1200 A 14-1/2 13-1/2 12-1/8 6-1/4 PV9B12N060UP11 1200 B 17-1/2 16-1/4 15-1/8 8-1/2 PV9B12N080UP11 1200 B 17-1/2 16-1/4 15-1/8 8-1/2 PV9C16N080UP11 1600 C 21 19-3/4 18-1/2 8-7/8 PV9C20N100UP11 2000 C 21 19-3/4 18-1/2 8-7/8 PV9D20N120UP11 2000 D 24-1/2 23-1/4 21-7/8 10-5/8 COMBUSTION AIR SUPPLY AND VENT PIPING MAXIMUM ELBOWS AND VENT LENGTHS Models Pipe Size Inches (cm) Maximum Number of Elbows* Minimum 1 2 3 4 5 6 7 8 Length 40,000 1-1/2 30 25 20 10 N/A N/A N/A N/A 5 40,000 2 70 65 60 55 50 45 35 25 5 60,000 1-1/2 (3.8) 30 25 20 10 N/A N/A N/A N/A 5 60,000 2 (5.1) 60 55 50 45 40 30 20 10 5 60,000 3 (7.6) 85 80 75 70 65 60 50 40 20 80,000 1-1/2 (3.8) 20 15 N/A N/A N/A N/A N/A N/A 5 80,000 2 (5.1) 60 55 50 45 40 30 20 10 5 80,000 3 (7.6) 85 80 75 70 65 60 50 40 20 100,000 2 (5.1) 25 20 15 N/A N/A N/A N/A N/A 5 100,000 3 (7.6) 85 80 75 70 65 60 50 40 20 120,000 3 (7.6) 75 70 65 60 55 45 35 25 5 036-21584-001 Rev. B (1004) HIGH ALTITUDE PRESSURE SWITCH APPLICATION Models High Altitude Pressure Switch Kit 4,500 Ft to 10,000 Ft. PV9A12N040UP11 1PS0506 PV9B12N060UP11 1PS0501 PV9B12N080UP11 1PS0502 PV9C16N080UP11 1PS0503 PV9C20N100UP11 1PS0505 PV9D20N120UP11 1PS0503 NOTE: For high altitude conversion, an orifice change may also be required. See Form 035-14447-001 for application information. ELECTRICAL AND PERFORMANCE DATA Models Input High/Low Output High/Low Nominal Airflow AFUE Air Temp. Rise Max. Outlet Air Temp. Blower Blower Size Total Unit Max. Over-current Protect Min. Wire Size (awg) @ 75 ft. One Way MBH MBH CFM % °F °F HP Amps In. Amps PV9A12N040UP11 40/26 38/24 1200 94.0 35-65 165 1/2 7.7 11x8 9 20 14 PV9B12N060UP11 60/39 56/36 1200 93.2 40-70 170 1/2 7.7 11x8 9 20 14 PV9B12N080UP11 80/52 75/49 1200 92.5 45-75 175 1/2 7.7 11x8 9 20 14 PV9C16N080UP11 80/52 75/49 1600 92.8 45-75 175 3/4 9.6 11x10 12 20 14 PV9C20N100UP11 100/65 93/60 2000 92.8 45-75 175 1 12.8 11x11 14 20 12 PV9D20N120UP11 120/78 112/73 2000 93.2 40-70 170 1 12.8 11x11 14 20 12 Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures. Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes. The furnace shall be installed so that the electrical components are protected from water. FILTER SIZES Models CFM Cabinet Size Side Return Filter in. (cm) Bottom Return Filter in. (cm) PV9A12N040UP11 1200 A 16 x 25 14 x 25 PV9B12N060UP11 1200 B 16 x 25 16 x 25 PV9B12N080UP11 1200 B 16 x 25 16 x 25 PV9C16N080UP11 1600 C 16 x 25 20 x 25 PV9C20N100UP11 2000 C 16 x 25 20 x 25 PV9D20N120UP11 2000 D (2) 16 x 25 22 x 25 * ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil. NOTES: 1. All filters must be high velocity cleanable type. 2. Air flows above 1800 CFM require either return from two sides or one side plus bottom. Unitary Products Group 036-21584-001 Rev. B (1004) AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM 40,000 INPUT - 3 Ton 60,000 INPUT - 3 Ton JUMPER SETTINGSCFM m./min CFM m./min High Low High Low High Low High Low COOL Tap ADJ Tap 1340 995 38.0 28.2 1330 900 37.7 25.5 A B 1205 885 34.1 25.1 1130 800 32.0 22.7 B B 1255 920 35.6 26.1 1220 850 34.6 24.1 A A 1150 835 32.6 23.7 1040 730 29.4 20.7 B A 1170 855 33.2 24.2 1120 770 31.7 21.8 A C 1025 755 29.0 21.4 920 650 26.1 18.4 C B 1045 780 29.6 22.1 950 660 26.9 18.7 B C 835 625 23.7 17.7 740 540 21.0 15.3 D B 950 705 26.9 20.0 860 610 24.4 17.3 C A 785 590 22.2 16.7 690 540 19.5 15.3 D A 865 665 24.5 18.8 790 570 22.4 16.1 C C 725 605 20.5 17.1 630 530 17.8 15.0 D C 80,000 INPUT - 3 Ton 80,000 INPUT - 4 Ton JUMPER SETTINGSCFM m./min CFM m./min High Low High Low High Low High Low COOL Tap ADJ Tap* 1310 890 37.1 25.2 1660 1110 47.0 31.4 A B 1100 740 31.2 21.0 1550 1050 43.9 29.7 B B 1220 830 34.6 23.5 1610 1070 45.6 30.3 A A 1000 670 28.3 19.0 1440 960 40.8 27.2 B A 1090 720 30.9 20.4 1470 990 41.6 28.0 A C 900 610 25.5 17.3 1370 920 38.8 26.1 C B 880 610 24.1 17.3 1290 850 36.5 24.1 B C 680 510 19.3 14.4 1130 790 32.0 22.4 D B 810 580 22.9 16.4 1230 850 34.8 24.1 C A 630 500 17.8 14.2 1050 720 29.7 20.4 D A 730 530 20.7 15.0 1110 760 31.4 21.5 C C 590 500 16.7 14.2 950 660 26.9 18.7 D C 100,000 INPUT - 5 Ton 120,000 INPUT - 5 Ton JUMPER SETTINGSCFM m./min CFM m./min High Low High Low High Low High Low COOL Tap ADJ Tap* 2210 1480 62.6 41.9 2280 151...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría