Iniciar sesión:
Votos - 1, Puntuación media: 3 ( )

Manual de usuario Addonics Technologies, modelo RAID TOWER IX RT93DAHX

Fabricar: Addonics Technologies
Tamaño del archivo: 132.3 kb
Nombre del archivo: RT93DAHX-RT93DAHXML_user_guide.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Installing drives into the RAID Tower V Step 1 Use a Philips screwdriver to secure the 3.5” SATA hard drive to the drive tray Step 2 Slide the tray into the Disk Array drive bay. Note: It is recommended to fill up the RAID Tower IX with SATA drives from top to bottom. This is to help in identifying which drives connects to which ports for easier troubleshooting. Note: The 5 port HPMXA system version PCB board is mounted inside the RAID tower and is connected to the multilane bridge that is mounted at the back of the RAID tower. Screws Screws eSATA Ports Multilane Port Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: RAID Setting Button Dip Switch SATA Host Port (Port 5) SATA Port 2 SATA Port 1 SATA Port 0 SATA Port 3 SATA Port 4 Drive activity LED Jumper Block (J1) Error LED Jumper Block (J3) Floppy Power Connector RAID Setting Button Dip Switch SATA Host Port (Port 5) SATA Port 2 SATA Port 1 SATA Port 0 SATA Port 3 SATA Port 4 Drive activity LED Jumper Block (J1) Error LED Jumper Block (J3) Floppy Power Connector Dip Switch Settings Raid Mode 1 2 3 4 5 Individual Drive (Factory Default) OFF OFF OFF OFF OFF 0 OFF OFF ON ON ON 1 and 10 OFF OFF ON ON OFF 3 OFF OFF ON OFF OFF 5 OFF OFF OFF ON OFF Clone OFF OFF OFF ON ON Large OFF OFF ON OFF ON Enable ERR Buzzer Function Auto- Rebuilding to Spare Drive Port Multiplier Mode Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: Default factory DIP Switch setting: SW1 – RAID Setting DIP Switch BZS – Error buzzer function EZ – Automatic rebuilding to spare drive (one of the drives on the raid is set as a spare). If EZ is ENABLED anda drive failure occurs, the spare will automatically act as a drive replacement and rebuilding will automatically start. M2 – RAID mode 2 M1 – RAID mode 1 M0 – RAID mode 0 SW1 1 2 3 4 5 BZS EZ M2 M1 M0 1. Error buzzer function is ENABLED (BZS) when dip switch is in OFF position 2. Auto-rebuilding to spare drive is DISABLED (EZ) 3. Individual drive mode is ENABLED (M0~M2) Note: When the default factory RAID setting is used, independent drive configuration and optical drive are supported only when connecting to controllers with Silicon Image Sil3124, Sil3132 chip set or controllers that are Port Multiplier (PM) compatible. Simultaneous DVD writing was tested using the Nero Burning Rom. LED Pin Header J3 J1 OFFOFFOFFOFFOFF P5 P0 P1 P2 P3 P4 P5 P0 P1 P2 P3 P4 Error LED Activity LED J1 – Drive Activity LED P5 – Activity LED for eSATA host port lights up when it is connected to a SATA controller card. P0, P1, P2, P3 & P4 - Activity LEDs for port 0, 1, 2, 3, 4 & 5 light up when a drive is connected and blinks when there’s drive activity. J3 – Error LED P5 – error LED for eSATA host port P0, P1, P2, P3 & P4 - error LED for port 0, 1, 2, 3, 4 & 5 Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: Setting or Modifying the RAID Mode Using the JMicron HW RAID Manager Utility Program: 1. For Windows users, install the JMicron HW RAID Manager located on the SATA Controller CD. In the CD, go to Configuration Utilities > JMB393. This manager can be use to create and monitor the status of the RAID volume. It is recommended to use the default factory RAID DIP switch setting when using the JMicron HW RAID Manager. 2. Modify the RAID mode on the 5-port HPM-XA using DIP switch Recommended to be used on operating system without JMicron HW RAID Manager support like Linux, Mac & Solaris. Windows users can also use the procedure below. Note: Steps A to D need to be performed each time the raid mode is modified. a. Set the DIP switch as shown below. OFFOFFOFFOFFOFF 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 b. Press the RAID setting button with a ball point pen. c. While pressing the RAID setting button turn on the system power where the HPM is connected. The buzzer will sound while holding the RAID setting button. Release it after at least 5 seconds for hardware initialization. A single beep will be heard to indicate initialization is completed. The above steps act as a reset. d. Power off the system power. Technical Support (M-F 8:30am - 6:00pm PST) Phone: 408-453-6212 Email: 1 2 3 4 5SW1 BZS EZ M2 M1 M0 1 2 3 4 5SW1 BZS EZ M2 M1 M0 SW1 SW1 1 2 3 4 5SW1 BZS EZ M2 M1 M0 RAID 5 Mode 1 2 3 4 5 SW1 BZS EZ M2 M1 M0 BZS EZ M2 M1 M0 RAID 1& RAID 10 Mode Large Mode 1 2 3 4 5 SW1 1 2 3 4 5 SW1 1 2 3 4 5 e. On the DIP switch, change (M0 to M2) setting to the desired RAID mode using the diagram below...

Otros modelos de este manual:
Eléctrico - RAID TOWER IX RT93DAHXML (132.3 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría