|
Otros manuales para este modelo:
Resumen del manual
For information about the trigger sources that can be selected for each sampling mode, see “Trigger Setup” (page 3-8). u uuuuuTo configure the Distance setting In place of step 3 of the procedure under “To configure Sample Setup settings”, press 1 to display a dialog box for specifying the distance the weight travels in meters. • Specify a value in the range of 0.1 to 4 meters. u uuuuuTo configure the FFT Graph setting In place of step 5 of the procedure under “To configure Sample Setup settings”, press 1 to display a dialog box for turning frequency characteristic graphing (FFT Graph) on and off. To do this: Press this key: Turn on graphing of frequency characteristics after sampling 1(On) Turn off graphing of frequency characteristics after sampling 2(Off) 20051101 3-8 Using Advanced Setup 3-8 Using Advanced Setup k Trigger Setup You can use the Trigger Setup screen to specify the event that causes sampling to start (w key operation, etc.) The event that causes sampling to start is called the “trigger source”, which is indicated as “Source” on the Trigger Setup screen. The following table describes each of the six available trigger sources. To start sampling when this happens: Select this trigger source: When the w key is pressed [EXE] key After the specified number of seconds are counted down Count Down When input at CH1 reaches a specified value CH1 When input at the SONIC channel reaches a specified value SONIC When the EA-200’s built-in microphone detects sound Mic When the EA-200’s [START/STOP] key is pressed [START] key Note The trigger sources you can select depends on the sampling mode selected with the Sample Setup (page 3-5). For this sampling mode: The following trigger source(s) can be selected: Realtime [EXE] key, Count Down Fast [EXE] key, Count Down, CH1, Mic Normal [EXE] key, Count Down, CH1, SONIC, [START] key Extended [EXE] key Sound [EXE] key, Count Down, Mic Clock CH1 Period CH1 20051101 Using AdvancedSetup 3-9 u uuuuuTo configure Trigger Setup settings 1. While the Advanced Setup menu (page 3-1) is on the display, press d(Trigger). • This displays the Trigger Setup screen with the “Source” line highlighted. • The function menu items that appears in the menu bar depend on the sampling mode selected with Sample Setup (page 3-5). The above screen shows the function menu when “Normal” is selected as the sample sampling mode. 2. Use the function keys to select the trigger source you want. • The following shows the trigger sources that can be selected for each sampling mode. Sampling Mode Trigger Source Realtime 1 (EXE) : [EXE] key, 2(Cnt) : Count Down Fast 1 (EXE) : [EXE] key, 2(Cnt) : Count Down, 3(CH1), 5 (Mic) Normal 1 (EXE) : [EXE] key, 2(Cnt) : Count Down, 3(CH1), 4 (Sonic), 5(STR) : [START] key Sound 1 (EXE) : [EXE] key, 2(Cnt) : Count Down, 5(Mic) • The trigger source is always “[EXE] key” when the sampling mode is “Extended”, and “CH1” when the sampling mode is “Clock” or “Period”. 20051101 3-10 Using AdvancedSetup 3. Perform one of the following operations, in accordance with the trigger source that was selected in step 2. If this is the trigger source: Do this next: [EXE] key Press w to finalize Trigger Setup and return to the Advanced Setup menu. Count Down Specify the countdown start time. See “To specify the countdown start time” below. CH1 Specify the trigger threshold value and trigger edge direction. See “To specify the trigger threshold value and trigger edge type”, “To configure trigger threshold, trigger start edge, and trigger end edge settings” on page 3-11 or “To configure PhotoGate trigger start and end settings” on page 3-12. SONIC Specify the trigger threshold value and motion sensor level. See “To specify the trigger threshold value and motion sensor level” on page 3-12. Mic Specify microphone sensitivity. See “To specify microphone sensitivity” below. [START] key Press w to finalize Trigger Setup and return to the Advanced Setup menu. u uuuuuTo specify the countdown start time 1. Move the highlighting to “Timer”. 2. Press 1 (Time) to display a dialog box for specifying the countdown start time. 3. Input a value in seconds from 1 to 10. 4. Press w to finalize Trigger Setup and return to the Advanced Setup menu. u uuuuuTo specify microphone sensitivity 1. Move the highlighting to “Sense” and then press one of the function keys describe below. To select this level of microphone sensitivity: Press this key: Low 1(Low) Medium 2(Mid) High 3(High) 2. Press w to finalize Trigger Setup and return to the Advanced Setup menu (page 3-1). 20051101 Using AdvancedSetup 3-11 u uuuuuTo specify the trigger threshold value and trigger edge type Perform the following steps when “Fast”, “Normal”, or “Clock” is specified as the sampling mode (page 3-5). 1. Move the highlighting to “Threshold”. 2. Press 1 (EDIT) to display a dialog box for specifying the trigger threshold value, which is value that data needs to attain before sampling starts. Sensor assigned to CH1 or SONIC by Channel ...
Otros modelos de este manual:Calculadoras - FX-9860GII (4.1 mb)
Calculadoras - FX-7400GII (2.61 mb)