Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Heat & Glo LifeStyle, modelo 6100PLUS

Fabricar: Heat & Glo LifeStyle
Tamaño del archivo: 1.82 mb
Nombre del archivo: 4041_127.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Keep clothing, furniture, draperies and other combustibles away. switch in the Fresh Air Fireplace. • R1 is energized 12VDC activating the IPI ignition circuit to initiate the fireplace ignition process. In the HRV, the R2 terminal must be jumpered to 12V to supply power to R1 at the Fresh Air Fireplace. • Thirty-second draft-proving delay timer activates. • The Fresh Air Fireplace lights. • The thirty-second draft-proving delay timer expires, C1 terminal is de-energized and the Fresh Air Fireplace pressure switch is monitored for sufficient flow at the flue collar for proper operation. IF SUFFICIENT FLOW IS NOT SENSED AT THE FLUE COLLAR OF THE FRESH AIR FIREPLACE AFTER THIRTY SECONDS OF OPERATION, THE FRESH AIR FIREPLACE FLAMES WILL EXTINGUISH LEAVING THE ELECTRIC EMBERS ILLUMINATED ONLY. THE FRESH AIR FIREPLACE WILL NOT SUSTAIN NORMAL OPERATION UNTIL THE LACK OF FLOW IS CORRECTED! • When there is adequate draft at the flow sensor and 12VDC is present at the R1 terminal on the circuit board, the green LED on the lower left side of the board illuminates. • When the user demand for appliance operation is removed, the HRV200PLUS de-energizes C1 and R1 terminals, terminating burner operation. • There is a 20 second delay (post-purge). • The HRV200PLUS de-energizes C1, turning the ember bed lights off. • The HRV200PLUS executes a five-minute low speed post purge. WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. WARNING Do NOT use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05 Note: The HRV200PLUS can use indoor air instead of the gas appliance for defrost if the optional defrost kit (part # HRV99DEFKIT) is installed. HRV200PLUS Defrost Mode • The HRV200PLUS demands gas appliance operation for defrost. This occurs when the following conditions exist: - The appliance is not in use. - The outdoor temperature falls below 25° F. - The DEFC1 jumper is not installed on the HRV200PLUS circuit board. • The HRV200PLUS does the following: - Turns blowers on to high speed. -Sends a 12VDC signal to the C2 terminal to light the ember bed lights (by energizing relay K3 on the appliance circuit board). This acts to notify the user the appliance is preparing to operate. - Positions HRV200PLUS dampers (if installed) for appliance operations. - Performs a 15 second delay (pre-purge) before the burners are lit. - Sends a 12VDC signal to the R1 terminal to initiate the ignition sequence (by energizing relay K1 on the circuit board). - Sends a 12VDC signal to the C1 terminal to override the pressure switch for the first thirty seconds of ignition. • The 6100PLUS senses adequate draft in the fl ow sensor (located in the appliance flue collar) to close the flow pressure switch. • The intermittent pilot ignition (IPI) system activates and lights the burner. • After thirty seconds, the HRV200PLUS de-energizes C1, placing the pressure switch into the 6100PLUS control circuit. The pressure switch monitors the flow at the flue collar of the 6100PLUS and shuts the appliance burner off if adequate flow is not present. • When the user demand for appliance operation is removed, the HRV200PLUS de-energizes the R1 terminal terminating burner operation. • There is a 20 second delay (post-purge). • The HRV200PLUS de-energizes C1, turning the ember bed lights off. Note: The appliance may operate to defrost the HRV200PLUS when the flame switch is in the “OFF” position. The appliance will only operate in “EMBER FIRE” mode during HRV200PLUS defrost. The electric ember bed will light for fi fteen seconds then the ember fire flame will ignite to defrost the HRV core. Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05 B. Lighting the Appliance Hearth & Home Technologies • 6100PLUS • 4041-127 Rev D • 09/05 C. After the Appliance is Lit Initial Break-in Procedure When you light the appliance, you may notice that it produces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up to 12 hours to fully drive off any odor from paint and lubricants used in the manufacturing process. Condensation of the glass is normal CAUTION • • • Prevent accidental appliance operation when not attended. Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time. Property damage possible from elevated temperatures. Note: This appliance should be run three to four hours on the initial start-up. Turn it off and le...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría