Resumen del manual


3. Mark the desired location on the floor and store the fireplace in a safe, dry and dust free location. 4. Use studs to frame an opening of 24 1/2 inches (622 mm) wide X 18 1/4 inches (463.6 mm) high X 8 7/8 inches (225.5 mm) deep. Option #1 - The power cord can be lead from behind the trim and along the wall to an outlet near the fireplace. Option #2 - A new outlet can be installed inside the new frame construction. Plug the unit into a 15Amp/120Volt outlet. If the cord does not reach, you may use an extension cord rated for a 5 Figure 2 18 1/4” (463.6 mm) 24 1/2” (622 mm) 8 7/8” (225.5 mm) minimum of 1875 watts. Option #3 -Hardwire 1. Wireadedicated,properlyfusedcircuitwith120Volt, 15Amp rating. Allow up to 8 feet of service cable for connecting power supply to junction box on fireplace when installing after finishing wall. CAUTION: Use two conductor, non-metallic sheath cable with ground wire (3 wires total) for the incoming power supply on fireplace inserts. Use appropriate wire to meet local and national electrical codes for rated power consumption. 2. Remove the outer jacket and strip the individual conductor from the end. 3. Loosen the screw securing the junction box cover and remove the cover. 4. Take the cables out from the junction box, loosen the two wire twist nuts and remove the cord set. (Figure 3) Figure 3 Figure 4 5. Route the power supply wire through the knockout on supplied alternative junction box cover and secure with a wire clamp (not supplied). (Figure 4) 6. Connect the black wire (live) from the unit to the black wire from 6 power supply. (Figure 4) 7. Connect the white wire (neutral) from the unit to the white wire from power supply. (Figure 4) 8. Connect the green wire (ground) from the unit to the green wire from power supply. (Figure 4) 9. Place all connectors inside the unit and secure the junction box cover to unit. Ensure that the cable clamp grips only the jacket of service cable. CAUTION: Clearance for air circulation beneath the fireplace insert is provided by two rubber feet. DO NOT INSTALLTHE FIREPLACE DIRECTLY ON CARPET OR SIMILAR SURFACES WHICH MAY RESTRICTAIR CIRCULATION. If installing the fireplace in a carpeted area, place a one-piece, solid, flat surface under the fireplace insert. Ensure that both of the insert’s feet rest securely on this surface. Figure 5 C BA 7 Operation (Figure 5) A. Main ON/OFF Switch The switch has two ON positions marked. The “ --“ position is for manual operation. In this position the built-in remote control is bypassed. The “ = “ position is for operating the unit with the provided remote control. When in remote control (“ = “) position the unit is operated with the ON and OFF buttons of the remote control. When the switch is in the center “o” position the unit is off. B. Heater ON Switch The Heat ON/OFF Switch supplies power to the heater fan and the heater element. When the switch is in the ON position the heater operates if the thermostat calls for heat. C. Heater Thermostat Control To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter-clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. Resetting The Temperature Cutoff Switch Should the heater overheat, an automatic cut out will turn the fireplace off and it will not come back on without being reset. It can be reset by switching the Main ON/OFF switch to OFF and waiting 5 minutes before switching the unit back on. CAUTION: If you need to continuously reset the heater, disconnect power and call Dimplex customer service at 1-888-DIMPLEX (1-888-346-7539). Remote Operation The fireplace is supplied with an integrated on/off remote control ! NOTE: Ensure that the fireplace Main ON/OFF switch is set to the remote control setting. 8 To operate, push the ON button to turn fireplace on, push the OFF button to turn the fireplace off. Battery Replacement (FIGURE 6) To replace the battery: 1. Slide battery cover open on the hand held transmitter. 2. Install one 12-Volt (A23) battery in the battery holder. 3. Close the battery cover. Remote Initialization In the event that your remote control ceases to operate your fireplace, follow these steps to re-initialize the handheld transmitter and the remote control receiver in the fireplace: 1. Place the Main ON/OFF Switch (Figure 5 A) in the OFF (“o”) position. 2. Wait a minimum of 5 seconds and then place the Main ON/OFF Switch in the Remote Control (“=”) position. 3. Within 10 seconds of changing the switch position, press the ON button located on the remote control transmitter (Figure 6). This will synchronize the remote control transmitter and the fireplace receiver. NOTE: You will have only 10 seconds to perform this last step. Failure to do so w...

Otros modelos de este manual:
chimeneas - DF2550 (657.07 kb)
chimeneas - DF2426GB (657.07 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría