Iniciar sesión:
Votos - 6, Puntuación media: 4 ( )

Manual de usuario Dimplex, modelo Electric Fireplace

Fabricar: Dimplex
Tamaño del archivo: 224.85 kb
Nombre del archivo: 80fd9e28-815c-4417-a44b-f40cb3ca82b6.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Pressing to the right turns the fireplace off. ALL MODELS WITHOUT REMOTE CONTROL. Heater ON/OFF switch, activates heater to high level. Text Box: 3 Text Box: FIGURE 3 WALL MOUNTED CONTROLS The fireplace can be installed with wall-mounted controls in addition to the controls provided. These controls include wall switches and thermostats. A. Wall Mounted Thermostats ALL MODELS WITH REMOTE CONTROL. When the fireplace is set to Level 2, or Level 3 the wall mounted thermostat will control the heat output of the unit. When the fireplace is set to Level 2, or 3 the heater will not activate until the wall mounted thermostat senses an ambient temperature lower than the temperature to which it is set. B. Wall Mounted Switches ALL MODELS WITHOUT REMOTE CONTROL ONLY. This model may be installed such that a wall- mounted switch activates the flame effect and a wall mounted thermostat activates the heater. RESETTING THE TEMPERATURE CUTOUT SWITCH The heater on this fireplace is protected with a safety device to prevent overheating. Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the Main Power switch (FIGURE 3) to OFF and waiting 5 minutes before switching it to ON. The remote control will need to be re-initialized (see page 2) Text Box: CAUTION · If you need to continuously reset the heater, disconnect the power at the main service panel and call your local dealer. Text Box: NOTE · The heater may emit a slight, harmless odor when first used. This odor is a normal condition caused by initial heating of internal heater parts and will not occur again. Text Box: 4 MAINTENANCE Light Bulb Replacement: Light bulbs need to be replaced when you notice a dark section of the flame. There are four bulbs under the log set which generate the flames and embers. Tool Requirements: Slot Screw Driver Bulb Requirements: Quantity of 4 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt rating. Example: GE 60BC or Philips 60CTC. Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs. Long life bulbs are recommended to reduce the frequency of bulb changes. Text Box: CAUTION · Do not exceed 60 watts per bulb. · When handling log only apply force to the ember bed section not directly to the logs. Text Box: NOTE · Allow at least 5 minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin. Text Box: WARNING · Disconnect all power coming to fireplace at main service panel before attempting any maintenance or cleaning to reduce risk of fire, electric shock or damage to persons Text Box: 5 To access the light bulb area: 1. Open steel curtain (remove glass doors if applicable). 2. Remove two screws on log grate and remove log grate (FIGURE 4). 3. Pull rear edge of ember bed up and forward by grasping ember bed by the sides (handle the logset only by the emberbed and not the logs) and pulling solidly until the rear tab pops out from under the back ledge, then lift out. (FIGURE 5) 4. Examine the bulbs to determine which bulbs require replacement. 5. Unscrew bulbs counter clockwise. 6. Insert new bulbs. 7. Replace the log by inserting front edge and pushing the back down until rear tab snaps under back ledge (FIGURE 5) and the logs are resting against mirror. 8. Replace log grate using two screws previously removed. Mirror Cleaning: The mirror is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the mirror surface may collect dust particles; these can be removed by buffing lightly with a clean dry cloth. To remove fingerprints or other marks, the mirror can be cleaned with a damp cloth using good quality household glass cleaner. The mirror should be completely dried with a lint free cloth or paper towel. Text Box: CAUTION · Do not use abrasive cleaners on mirror surface or spray liquids directly onto any surface. Text Box: FIGURE 4 Text Box: FIGURE 5 Text Box: 6 WARRANTY Dimplex Optiflame Electric Fireplaces are tested and inspected prior to shipment and are guaranteed from defect to the purchaser of each new product. Any part which proves to be defective in material or workmanship under normal use within on year will be repaired or replaced without charge.* The Company will not be responsible for any expense incurred for installation, removal from service, or transportation costs. Any such defect should be brought to the attention of the Dealer where the product was purchased and is authorized to repair or replace within the terms of this warranty. The Company’s only obligation under this warranty will be at its sole option to repair or replace any part proving defective or to refund the purchase price thereof. The owner/user assumes all other risks, if any, including the ris...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría