When locked in position all the way Up (to the rear), the damper is Closed. The appliance flue damper must always remain open when operating. Damper Closed DamperOpen Lintel Combustion Air Actuator Figure 2 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. GLASS DOOR OPERATING SAFETY PRECAUTIONS AND INSTRUCTIONS These fireplaces are equipped with glass doors. Only use the doors provided with this fi replace. WARNING Your fireplace is equipped with glass doors, it should be oper ated with the doors fully open or fully closed. If the doors are left partially open, gas and flames may be drawn out of the opening, creating risks of both fire and smoke. Refer to Figure 3 for proper operating conditions. Figure 3 Glass Doors Fully Open or Fully Closed (Bi-Fold Doors) CAUTION If a smoking condition exists, glass doors should be closed during fi replace operation. Care and Cleaning of Your Glass Doors Never clean the glass when the doors are hot. Do not use ammonia or ammonia based glass or household cleaner to clean the glass or the door frame. An ammonia based cleaner will damage the fi nish of the glass door. Clean the glass doors by wiping with a damp towel followed by a clean dry towel to remove streaks. Remove stubborn stains from the glass with a mild soap solution and a towel dampened with clean water. Dry with a clean dry towel. • The fire must always be confined within the boundaries of the fuel grate. • The fireplace screens must always be closed whenever the fi replace is being used. • Never slam the glass door since it could cause the glass to break. • Do not build excessively large or hot fires — scorching or discoloring of the solid brass or plated brass trim may occur. • • • If the tempered glass pane becomes scratched or chipped, it creates a weakness in the glass which can cause the glass to break when heated. Replace the entire glass door as an assembly by contacting your nearest dealer. CAUTION Glass, metal frames, handles and other components of the fi replace get hot. Use handles and wear thermal insulating gloves or other effective protection or tool to open and close the doors or screens. IMPORTANT The lacquer coating on the polished brass glass doors can be damaged or removed causing corrosion and/or tarnish. To help protect the solid brass; use a non-acidic wax and avoid the over-spray of acidic/alkali based glass cleaners on the brass pieces. If the solid brass begins to turn black, all the protective coating should be removed and the metal re-polished, either by hand or professionally. Subsequently, the finish will not be as “bright” or lustrous without the protective coating. Solid polished brass will acquire a patina over years of use. This is a normal occurrence and can be polished. COMBUSTION AIR A proper amount of combustion air is important for your fireplace. Fireplaces consume large amounts of oxygen. It is important to allow an adequate supply of air. This fireplace is equipped with an outside air kit, to provide sufficient amounts of combustion air from outside of the house or structure in which it is installed. With the outside combustion air kit closed, the fire may draw from an outside air source and pull air in through the chimney. This may cause smoke spillage into the room. Smoke spillage often occurs when a fire is first started, until the fireplace and the chimney has had the opportunity to “come up to temperature” and to begin to function normally. If smoke spillage problems persist, a window may be opened just a crack to allow the proper flow of combustion air to the fi replace. Your fireplace is equipped with an outside combustion air kit, keep it open at all times when fire is burning and close when fire is out to prevent cold air intrusion. Combustion Air Control The actuator for combustion air system is standard on all fireplaces but must not be operated if the complete system is not installed. See Figure 4 and refer to Figure 2. If you have reason to believe that you do not have a complete outside combustion system, contact your distributor to have your fi replace inspected for the presence of the complete system before you use the combustion air actuator. DO NOT assume that you have this system in place because you have an actuating lever present on your fi replace front face. WARNING Do not operate the combustion air gate actuator unless a complete outside combustion air vent system has been installed with your Fireplace. To provide outside combustion air to your fireplace while it is in operation, locate the combustion air actuator along the right side of the fi replace opening behind the screen. To operate, push the end of the actuator to the left as shown in Figure 4, until it "pops" free of its "locked" position. Pull the actuator forward to open the combustion air door, and push it back to close. Figure 4 Combustion Air Actuator Pull Forward to Open, Push Back to Close Air Gate Kit (purchased separately) WARNING Be aware that safety glass is unpredictable wh...
Otros modelos de este manual:chimeneas - HCD36MH (438.14 kb)
chimeneas - HCD36MH (438.14 kb)
chimeneas - HCD36MH (438.14 kb)
chimeneas - HCD36MH (438.14 kb)