7. Twist-lock the vent cap onto the kast section of vent pipe. Note: If the vent pipe passes through any occupied areas above the first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock the enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any of the required air spaces with insulation. If area above is a room, install If the area above is not a room, install firestop above framed hole. firestop below framed hole. Note: Vertical restrictor must be installed in all vertical installations. 1. Determine the route your vertical venting will take. If ceiling Joists, roof rafters, or other framing will obstruct the venting system, consider an offset (see Figure 26) to avoid cutting load bearing members. NOTE: Pay special attention to these instal- lation instructions for required clearances (air space) to com- bustibles when passing through ceilings, walls roofs, enclo- sures, attic rafters, etc. Do not pack air spaces with insulation. Also note maximum horizontal offset limitations. 2. Set fireplace in desired location. Drop a plumb line down from the ceiling to the position of the fireplace exit flue. Mark the center point where the vent will penetrate the ceiling. Drill a small locating hole at this point. Drop a plumb line from the inside of the roof to the locating hole in the ceiling. Mark the center point where the vent will penetrate the roof. Drill a small locating hole at this point. 45° ElbowWall StrapRoof FlashingCeiling Firestop Figure 26 - Offset with Wall Strap and 45° Elbows Flat Ceiling Installation 1. Cut a 10 .” square hole in the ceiling using the locating hole as a center point. The opening should be framed to 10 .” x 10 .” (273 mm x 273 mm) inside dimensions, as shown in Figure 12 on page 9 using framing lumber the same size as the ceiling joists. If the area above the ceiling is an insulated ceiling or a room, nail firestop from the top side. This prevents loose insula- tion from falling into the required clearance space. Otherwise, install firestop below the framed hole. The firestop should be installed with no less than three nails per side (see Figure 27). Figure 27 - Installing Firestop VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Termination (Cont.) VENTING INSTALLATION INSTRUCTIONS Continued 90° ElbowNote: Installrestrictor ringinto inner pipesection prior toattaching venttermination cap. Venting with Two 90° ElbowsVertical (V)Horizontal H8' min.6' max. 9' min.8' max. 10' min.10' max. 12' min.14' max. 14' min.18' max. 40' max.20' max. Vertical Termination Configurations Figures 28 through 31 show four different configurations for verti- cal termination. Venting with Three 90° ElbowsVertical (V) Horizontal (H2) Horizontal (H1) + 8' min.5' max. 10' min.8' max. 12' min.11' max. 14' min.14' max. 16' min.17' max. 90° ElbowNote: Installrestrictor ringinto inner pipesection prior toattaching venttermination cap. 18' min.20' max. 40' max.20' max. Figure 29 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination) 90° ElbowNote: Vertical (V1) + Vertical (V2) = 40' max. Venting with Two 90° ElbowsVertical (V1)Horizontal (H) 8' min.9' max. 9' min.11' max. 10' min.13' max. 12' min.17' max. 14' min.20' max. Note: Installrestrictor ringinto inner pipesection prior toattaching venttermination cap. Max. Horizontal Above 14' Vertical = 20' Figure 28 - Vertical Venting Configuration using Three 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination) Figure 30 - Vertical Venting Configuration Using Two 90° Elbows (Model (V)CD36T with Vertical Round High Wind Termination) VENTING INSTALLATION INSTRUCTIONS Installation for Vertical Terminations Cont.) Parts Lists for Venting Kits Components VENTING INSTALLATION INSTRUCTIONS Continued Vertical VentingV = 40' max. Note: Installrestrictor ringinto inner pipesection prior toattaching venttermination cap. PARTS LISTS FOR VENTING KITS AND COMPONENTS DESA (5/8”) Pipe & Vent Kits Number Description P58-6 6” Section Double Wall Pipe Galvanized P58-12 12” Section Double Wall Pipe, Galvanized P58-24 24” Section Double Wall Pipe, Galvanized P58-36 36” Section Double Wall Pipe, Galvanized P58-48 48” Section Double Wall Pipe, Galvanized PA58-712 Adjustable 7”-12” Section Double Wall Pipe, Galva- nized FPA58-6 6” Duravent Collar to FMI Pipe Adaptor (6” Collar/ Pipe Section) DPA58-6 6” FMI Collar to Pipe Duravent Adaptor (6” Collar/ Pipe Section) E58-45 45° Elbow, Galvanized E58-90 90° Elbow Galvanized FSE58-45 45° Starter Elbow, Galvanized (Duravent Collar to FMI Pipe) DSE58-45 45° Starter Elbow, Galvanized (FMI Collar to Dura- vent Pipe) VKG-58 Ground Floor Vent Kit VKB-58 Basement Vent Kit VKC-58 Corner Vent Kit VKS-58 Snorkeo Vent Kit VKC-58 Corner Vent Kit HTK Horizontal Round Termination Kit HT-58 Horizontal Round Termination, Galvanized HTKS-58 Horizontal Squa...

Otros modelos de este manual:
chimeneas - (V) CD36T(N (6.22 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría