Resumen del manual


Replace gas regulator 1. Check burner(s) for dirt and debris. If found, clean burner(s) (see Cleaning and Maintenance, page 27) 2. Replace gas regulator Slight smoke or odor 1. Residues from manu-1. Problem will stop after a during initial operation facturing processes few hours of operation and logs curing 1. Turn control knob to LO position and let warm up for a minute 2. Operate burners until air is removed from line. Have gas line checked by local propane gas company 3. Observe minimum installation clearances (see page 11) 4. Clean burners (see Cleaning and Maintenance, page 27) or replace burner orifice(s) 1. Refer to Air for Combustion and Ventilation requirements (page 6) Continued TROUBLESHOOTING Continued WARNING If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, call the fire department. IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. OBSERVED POSSIBLE PROBLEM CAUSE REMEDY Fireplace produces a 1. Metal expanding while 1. This is common with most clicking/ticking noise heating or contracting fireplaces. If noise is just after burners are while cooling excessive, contact qualilit or shut off fied service person Fireplace produces unwanted odors Fireplace shuts off in use (ODS operates) 1. Fireplace burning vapors from paint, hair spray, glues, cleaners, chemicals, new carpet, etc. (See IMPORTANT statement above) 2. Gas leak. See Warning statement above 1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged 1. Open window and ventilate room. Stop using odor causing products while fireplace is running 2. Locate and correct all leaks (see Checking Gas Connections, page 18) 1. Open window and/or door for ventilation 2. Contact local natural gas company 3. Clean ODS/pilot (see Cleaning and Maintenance, page 27) 1. Gas leak. See Warn-1. Locate and correct all Gas odor even when ing statement above leaks (see Checking Gas control knob is in OFF Connections, page 18) position 2. Control valve defective 2. Replace control valve Gas odor during combustion 1. Foreign matter between control valve and burner 2. Gas leak. See Warning statement above 1. Take apart gas tubing and remove foreign matter 2. Locate and correct all leaks (see Checking Gas Connections, page 18) 30 1. Not enough combus-1. Refer to Air for CombusMoisture/ condensation tion/ventilation air tion and Ventilation noticed on windows requirements (page 6) SERVICE HINTS SPECIFICATIONS TECHNICAL SERVICE PARTS CENTRALS When gas pressure is too low • pilot will not stay lit • burners will have delayed ignition • fireplace will not produce specified heat • propane/LP gas supply may be low When gas quality is bad • pilot will not stay lit • burners will produce flames and soot • fireplace will backfire when lit You may feel your gas pressure is too low or gas quality is bad. If so, contact your local natural gas supplier. BTU (Variable) Type Gas Ignition Manifold Pressure Inlet Gas Pressure (in. of water) Maximum Minimum* (*For purpose of input adjustment) Shipping Weight 20,000/28,000 Natural Gas Only Piezo 3.4" W.C. 10.5" 5" 80 lbs. You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Service Department at 1-800-DESA LOG (1-800-337-2564). These Parts Centrals are privately-owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 E. Valparaiso, IN 46383 All States 219-462-7441 1-800-362-6951 Parts Department FBD P.O. Box 1096 1720 Kummer Road Franklin, KY 42134 502-586-1922 1-800-654-8534 Four Flags Power Products 1115 Stateline Road Niles, MI 49120 616-684-2697 Parts Only Master Parts Distributor 1184 Wilson Ave. NW Grand Rapids , MI 49504 616-791-0505 1-800-446-1446 Fax: 1-616-791-8270 Parts Department Washer Equipment Co. 1715 Main Street Kansas City, MO 64108 KS, MO, AR 816-842-3911 Parts Department East Coast Energy Products 707 Broadway W. Long Branch, NJ 07764 908-870-8809 1-800-755-8809 Parts Department Tarantin Tank Co. P.O. Box 6129 Freehold, NJ 07728 908-780-9340 1-800-922-0724 Parts Department Albany Ladder 1586-90 Central Avenue Albany, NY 07728 NY, MA, VT 518-869-5335 1-800-354-7368 (NY, MA, VT) Parts Department Dayton Hardware P.O. Box 275 North Dayton Station Dayton, OH 45404 All States 513-258-3721 OH 1-800-762-3426 Parts Departmen...

Otros modelos de este manual:
chimeneas - CGF280NT (920.57 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría