2. Apply a bead of Mill-Pac Black (700° F, high temperature sealant - Catalog No. 10K81) to the outer adapter collar; to the grooves of the collar which extend approximately 1 inch from the end and to the flat surface, approximately 1 3/8 inches from the end. 3. Pull and extend outer flexible vent pipe. 4. Slide the outer flex pipe over the adapter collar. Ensure the flexible vent pipe completely engages the adapter collar to a distance of 1... inches from the end, and that it is free from damage or tears. 5. Slide the gear clamp down and tighten it fully to secure the flexible vent to the adapter outer collar approximately 3/4 inch from the end of the flex. 6. Install three screws, 120 degrees apart, through the flexible vent pipe and into the adapter collar just below the gear clamp to provide additional security to the connection. C. Route Flex Vent Ensure that the flex vent is properly routed to provide the required clearance. Do not allow the flexible vent to bend in a radius tighter than 5" (127 mm). Refer to Figure 45. Space out the internalflexventspacersevenly -approximately every 6 inches -and avoid kinking of inner pipe. Support horizontal sections of flex with metal straps at 2 foot (0.61 m) intervals. NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. D. Install Firestop / Spacers at ceilings and walls -When Secure Flex penetrates a wall or ceiling, a firestop / spacer is required: use the SF4.5 VF firestop / spacer for ceilings and the SF4.5 HF firestop / spacer for walls. See the appropriate sections and Figures shown throughout the venting section for their installation requirements. Flexible Vent Section 5” (127 mm) Radius Minimum Figure 45 E. Attach Flex Vent to Termination Secure Flex components can be purchased separately and attached to bulk lengths of Secure Flex flexible tubing cut to size at the job site. Secure the flexible vent to the Secure Flex terminations in the same manner (see Figure 44) as it was attached to the adapter. Note: Secure Flex vent must be attached to Secure Flex terminations only. DO NOT substitute Secure Vent terminations or the Secure Vent adapter for Secure Flex components. The collars of Secure Flex terminations and adapters have a different diameter than that used with the Secure Ventpipe. Additionally,SecureFlexcomponents have an extended length center tube for use in attaching the flexible vent. Step 4. FIELD WIRING Step 4. FIELD WIRING Ground supply lead must be connected to the wire attached to the green ground screw located on the outlet box. See Figure 47.Failureto do so willresult in apotential safety hazard. The appliance must be electricallygroundedinaccordance withlocalcodesor,intheabsenceof local codes, the National Electrical Code, ANSI/NFPA 70 latest edition. (In Canada, the current CSA C22-1 Canadian Electrical Code). CAUTION: Label all wires prior to disconnectionwhenservicingcontrols. Wiringerrorscan cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, etiquetez tous les fils avant de les debrancher. Des erreurs de cablage peuvent entrainer un fonctionnement inadequat et dangereux. Verify proper operation after servicing. S'assurer que l'appareil fonctionne adequatement une fois l'entretien termine. Note: The gas valve is set in place and pre-wired at the factory. A. SIT and Honeywell Millivolt Wiring (See Figure 46) 1. Select anyofthefollowingoptionalcontrols: unit-mountedburnerOFF/ON switch(rocker switch),wall-mounted switchor the remote controlkit.Ifunit-mountedON/OFFcontrolis selected mount it in the gas valve mounting bracket. 2. If wall-mounted ON/OFF control is selected mount it in a convenient location on a wall near the fireplace. 3. Wire the control within the millivolt control circuit using the 15 feet of 2 conductor wire supplied with the unit . Caution: do not connect the optional wall switch to a 120V power supply. 4. Alternatively, the appliance may be operated without the use of the controls indicated in step 1, solely by manipulating the gas valve control knob. In order to use this method, twist the free ends of the two conductor wire (which would otherwise go to the standard ON/OFF switch or Optional Switch) together as shown in Figure 46. Note: Wire is located inside the control compartment Note: The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the control compartment. FORCED AIR BLOWER (FBK-100 provided) (See Figure 47) - The blower and blower ON/Off control switch are factory installed. An electrical outlet box is also factory installed for the connection of the electrical power supply to the blower. 1. Route a 3-wire, 120Vac 60Hz 1ph power line to the lower right rear corner of the appliance. 2. Connect the black supply wire to the top outlet's black pigtail lead and to the switch's black lead. Connect the white supply wire to the neutral terminal of the outlet box. 3. Conn...

Otros modelos de este manual:
chimeneas - SDV35 (4.91 mb)
chimeneas - SDV35 (4.91 mb)
chimeneas - SDV35 (4.91 mb)
chimeneas - SDV35 (4.91 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría