Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Lennox Hearth, modelo MNTSVBE

Fabricar: Lennox Hearth
Tamaño del archivo: 765.57 kb
Nombre del archivo: 5a275cf1-518d-4654-ba53-6661e581c4cd.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


... CONTROL COMPARTMENT ACCESS PANEL 20.... (510) OUTSIDE AIR SHUTTER A - 6 (152) DIA. FLUE OUTLET B - 8 (203) DIA. FLUE COLLAR BA Figure 14 Figure 15 Step 4. FIELD WIRING Refer to Section A for millivolt appliances and Section B for electronic appliances. The gas valve is set in place and pre-wired at the factory on both models. A. Millivolt Wiring (See Figure 16 ) 1. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed in the modesty panel. Optional wall-mounted switch, thermostat, or one of the optional remote control kits may also be used. 2. If wall-mounted ON/OFF control or thermostat is selected, mount it in a convenient location on a wall near the fireplace. 3. Wire the control switch within the millivolt control circuit using the 15 feet of 2 conductor wire supplied with the unit. Note:The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductorplaced loose inside the lower compartment of the unit. Caution: do not connect the optional wall switch to a 120V power supply. 4. If an optional control switch is installed, turn the appliance-mounted ON/OFF burner control switch to the OFF position. Figure 16 Thermopile THTP TH TP White WhiteBlack Millivolt Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. *OPTIONAL WALL-MOUNTED ON/OFF SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE RECEIVER *Turn the appliance-mounted ON/OFF burner control switch to the OFF position if an optionalcontrol switch is installed. Factory Wired Field Wired Schematic Representation Only APPLIANCE-MOUNTED ON/OFF SWITCH LIMIT SWITCH B. Electronic Wiring (also see Figure 18 on page 11 ) Note:The electronic appliance must be connected to the main power supply. 1. Route a 3-wire 120Vac 60Hz 1ph power supply to the appliance junction box. 2. Open the control compartment access panel, by actuating the spring-loaded magnetic catches securing the panel, gently depressing the outer top corners of the panel until the catches "pop" the panel free and allowing it to swing out and down to open. 3. Remove the bottom control compartment access panel by compressing the spring- loaded hinge pin on the left side until it disengages from the left cabinet panel hole. Pull the panel away from the fireplace. See Figure 20 on page 12. 4. Remove the modesty panel by pulling the bottom edge of the modesty panel out of the locking slots of the cabinet bottom. Then tilt the top edge at a 45° angel and lift out. Remove the modesty panel carefully, so that none of the wires become loose or disconnected. 5. Remove the outlet receptacle by removing the two securing screws. See Figure 17.(The left and right designations used here are reversed in EBVCR applications.) 6. Install a field-provided strain relief in the cabinet knockout opening for the protection of the power supply wires. 7. Connect the power supply wires to the receptacle as shown in Figure 18 on page 11. 8. Connect the ground supply wire and the green wire attached to the outlet receptacle's green ground screw. 9. Appliance-mounted ON/OFF burner control switch (rocker switch) is factory installed in the modesty panel. Optional wall-mounted switch, thermostat, or one of the optional remote control kits may also be used. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. OUTLET RECEPTACLE INSTALLATION Figure 17 EBST-2, EBPF-2 AND EBCL-2 OUTLET RECEPTACLE SHOWN. EBCR-2 HAS THE OUTLET RECEPTACLE LOCATED IN THE LEFT CORNER OF THE UNIT EBBAY OUTLET RECEPTACLE LOCATED IN THE REAR LEFT CORNER OF THE UNIT VIEW OF RIGHT BOTTOM CORNER OF UNIT OUTLET RECEPTACLE JUNCTION BOX OUTLET RECEPTACLE BOX SECURING SCREW CABINET RIGHT SIDE PANEL FIREBOX BOTTOM EBST-2, EBPF-2 AND EBCL-2 OUTLET RECEPTACLE SHOWN. EBCR-2 HAS THE OUTLET RECEPTACLE LOCATED IN THE LEFT CORNER OF THE UNIT EBBAY OUTLET RECEPTACLE LOCATED IN THE REAR LEFT CORNER OF THE UNIT VIEW OF RIGHT BOTTOM CORNER OF UNIT OUTLET RECEPTACLE JUNCTION BOX OUTLET RECEPTACLE BOX SECURING SCREW CABINET RIGHT SIDE PANEL FIREBOX BOTTOM 10. If wall-mounted ON/OFF switch or thermostat is to be used, mount it in a convenient location on a wall near the fireplace. 11. If the wall-mounted ON/OFF switch is to be used, wire it to the the low voltage circuit as shown in Figure 18. Note:The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductorplaced loose inside the lower compartment of the unit. 12. After wiring is complete, reinstall the outlet receptacle; install the field-provided the metal junction box cover plate; reinstall the modesty panel. Note:The gas valve ON/OFF switch is shown in Figure 18. It is integral with the gas valve and should be set to theONposition. IMPORTANT: Ground supply wire must be connected to the green wire attached to the outlet receptacle's green ground screw. See Figure 18. Failu...

Otros modelos de este manual:
chimeneas - MNTSVBE (765.57 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría