Iniciar sesión:
Votos - 5, Puntuación media: 4 ( )

Manual de usuario Napoleon Fireplaces, modelo Castlemore GDS26N

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 3.99 mb
Nombre del archivo: 71544c04-54dd-7964-450d-785fba4db7e3.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Maximum input is 25,000 BTU/hr for natural gas and propane. Maximum output is 20,500 BTU/hr at an efficiency of 82%. Provide adequate accessibility clearance for servicing and operating the stove. Never obstruct the front opening of the stove. Provided that the clearance to combustibles are achieved, the most desirable and beneficial location for a Napoleon® stove is in the centre of a building, thereby allowing the most efficient use of the heat created. The location of windows, doors and the traffic flow in the room where the stove is to be located should be considered. If possible, you should choose a location where the vent will pass through the house without cutting a floor or roof joist. Rating Label Location: The rating label is located behind the control door and is chained to the stove. DO NOT REMOVE. CARE OF GLASS AND PLATED PARTS Do not use abrasive cleaners to clean these parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon® / Wolf Steel Ltd. dealer. DO NOT SUBSTITUTE MATERIALS. Clean the glass after the first 10 hours of operation with a recommended gas stove glass cleaner. Thereafter clean as required. DO NOT CLEAN GLASS WHEN HOT! If the glass is not kept clean permanent discolouration and / or blemishes may result. W415-0607 / A / 01.18.08 FIGURE 1a 35 1/2” 37” 18 1/8” 23 5/8” 4” DIA. 7” DIA. GAS LINE ACCESS ELECTRICAL ACCESS 29 1/8” DIMENSIONS FIGURE 1b FIGURE 1c VENTING VENTING LENGTHS AND AIR TERMINAL LOCATIONS Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp or American Metal Amerivent venting components. Minimum and maximum vent lengths, for both horizontal and vertical installations, and air terminal locations for either system are set out in this manual and must be adhered to. For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure provided with the venting components. All outer pipe joints of these venting systems must be sealed using Red RTV High Temperature Sealant. The connection between the adaptor for these systems and the stove flue collar must be sealed using the black high temperature sealant Mill Pac (not supplied). A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier: PART 4"/7" SUPPLIER Duravent GDS924N Wolf Steel Amerivent 4DSCB-N1 American Metal Direct Temp 4DT-AAN Selkirk For Simpson Dura-Vent, Selkirk Direct Temp and American Metal Amerivent, follow the installation procedure found on the website for your venting supplier: VENTING SUPPLIER WEBSITE ADDRESS Simpson Dura-Vent Selkirk Direct Temp American Metal Amerivent For vent systems that provide seals on the inner exhaust flue, only the outer air intake joints must be sealed using a red high temperature silicone (RTV). This same sealant may be used on both the inner exhaust and the outer intake vent pipe joints of all other approved vent systems except for the exhaust vent pipe connection to the stove fl ue collar which must be sealed using the black high temperature sealant Mill Pac. When using Wolf Steel venting components, use only approved Wolf Steel rigid / flexible components with the following termination kits:Wall Terminal Kit GD222, or 1/12 to 7/12 Pitch Roof Terminal Kit GD110, 8/12 to 12/12 Roof Terminal Kit GD111, Flat Roof Terminal Kit GD112 or Periscope Kit GD201 (for wall penetration below grade). Also approved for use with Duravent's co-axial to co-linear adaptor for installations using an existing chimney. The maximum allowable vertical vent length is 40 feet, the minimum allowable vertical vent length is 3 feet. For optimum flame appearance and stove performance, keep the vent length and number of elbows to a minimum. The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that it is unobstructed and undamaged. Horizontal runs may have a 0" rise per foot in all cases using Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent rigid venting components or Wolf Steel flexible venting components. For optimum performance, it is recommended that horizontal runs have a minimum 1" rise per foot when using Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Wolf Steel rigid / flexible vent components. Wolf Steel, Simpson Dura-vent, Selkirk Direct Temp, and American Metal Amerivent venting systems must not be combined. VENT INSTALLATIONS For safe and proper operation of the stove follow the venting instruction exactly. Deviation from the minimum or the maximum vertical vent length can create difficulty in burner start-up and/or carboning. Under extreme vent configurations, allow several minutes (5-15) for ...

Otros modelos de este manual:
chimeneas - Castlemore GDS26P (3.99 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría