Iniciar sesión:
Votos - 1, Puntuación media: 3 ( )

Manual de usuario Napoleon Fireplaces, modelo BGD36CFNTR

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 5.96 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


HINT: If glass falls into cup and surrounds the orifice, insert a clean bag into a vacuum cleaner and vacuum out glass embers or replacement glass embers can be ordered from Wolf Steel Ltd. Note: The distribution of clear glass embers over the burner tube will influence the flame height. W415-0661 / C / 02.20.08 OPTIONAL BLOWER INSTALLATION OPTIONAL BLOWER INSTALLATION BGD36CF(G) ACCESSING THE BLOWER 1. Remove the valve access door. 2. Open the main door. 3. Carefully remove the logs. 3a. (BGD36CFG) Carefully remove the glass and glass ember tray. 4. Remove the 7 screws illustrated in Fig. 112a and lift out the log support. 4a. (BGD36CFG) Remove the top deflector and porcelain panels from the firebox. (See Figure 109). FIGURE 112aFIGURE 112a 5. Remove the 8 perimeter screws as illustrated in Fig. 112a and lift out the burner base. (The gas line flex-connector should pro- vide sufficient move- FIGURE 112bFIGURE 112b ment to permit shifting the burner assembly to the side). 6. Reverse procedure to re-assemble. BGD42CF ACCESSING THE BLOWER 1. Remove the main door using the instructions on Pg #29. 2. Carefully remove the logs. 3. Remove the grate by lifting it off of the two securing pins. 4. Remove the 6 screws illustrated in Fig. 112b and lift out the log support. Be careful not to lose the spacers for the screws indicated. FIGURE 113FIGURE 113 5. Remove the 7 perimeter screws as illustrated in Fig. 113 and lift out the burner base. (The gas line flex-connector should provide sufficient movement to permit shifting the burner assembly to the side). 6. Reverse procedure to re-assemble. FIGURE 114FIGURE 114 INSTALLING THE BLOWER FIGURE 116 INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States FIGURE 117 If the fireplace was not previously equipped with a blower: route a grounded 2-wire, 60hz power cable to the receptacle / junction box. At this point, it must be strain relieved and in sulated. Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30-45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat. The three slots on the blower mounting bracket allow ease of adjustment when attaching the blower. For a quiet running blower, do not allow the assembly to sit on the firebox base. Slide the vibration reducing pad (A) into the clip (C) and up against the threaded stud (B) at the other end. The blower must be able to be positioned entirely onto the pad. To ease installation of the blower, remove the hinge screen and valve control door (lower louvres) from the base of the fireplace. Tilt the blower onto its side. Slide it past the controls and into the clip (C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fireplace base or the firebox. AA BB FIGURE 118aFIGURE 118a CC FIGURE 118bFIGURE 118b W415-0661 / C / 02.20.08 Attach the connectors from FIGURE 119 the black and white wires to the thermodisc and secure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall. Attach the connectors from the black and red wires to the blower. Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle. Note: To improve access to the variable speed control, we recommend bending the mounting bracket forward by approximately 10°. The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects. Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy. FIGURE 120 OPTIONAL FAN INSTALLATION ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States. FIGURE 121 To safely install the fan, turn off the electricity first. If the fi replace was not previously equipped with a fan: route a grounded 2-wire, 60hz power cable to the junction box. At this point, it must be strain relieved and insulated. The wire harness provided in this FIGURE 122 kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects. To ease i...

Otros modelos de este manual:
chimeneas - BGD36CFGN (5.96 mb)
chimeneas - BGD42CFN (5.96 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría