Manual de usuario Napoleon Fireplaces, modelo BGD48N

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 2.41 mb
Nombre del archivo: f38531ea-18fc-c8d4-3d0f-88ba5b1e6033.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


pilot stays on. not engulfing the thermopile - replace pilot assembly. Thermopile shorting - clean thermopile connection to the valve. Reconnect. -replace thermopile / valve. Remote wall switch wire is too -shorten wire to correct length or wire gauge. long; too much resistance in the system. Faulty thermostat or switch. -replace. Main burner goes out; Refer to "MAIN BURNER GOES OUT; PILOT STAYS ON" pilot goes out. Vent is blocked -check for vent blockage. Vent is re-circulating -check joint seals and installation. 5" flexible vent has become dis--reattach to fireplace. connected from fireplace. Pilot goes out when the gas knob is released. The gas valve has an interlock device which will not allow the pilot burner to be lit until the thermocouple has cooled. Allow approximately 60 seconds for the thermocouple to cool. System is not correctly purged. Out of propane gas. -purge the gas line with the glass door removed. -fill the tank. Pilot flame is not large enough -turn up the pilot flame. Pilot flame is not engulfing the -gently twist the pilot head to improve the flame pattern around the thermothermocouple. couple. Thermocouple shorting / faulty. Faulty valve. -loosen and tighten thermocouple. -clean thermocouple and valve connection. -replace thermocouple. -replace valve. -replace. Pilot burning; no gas Themostat or switch is defec--connect a jumper wire across the wall switch terminals; if main burner lights, to main burner; gas tive. replace switch / thermostat. knob is on 'HI'; wall Wall switch wiring is defective. -disconnect the switch wires & connect a jumper wire across terminals 1 & 3; if switch / thermostat the main burner lights, check the wires for defects and / or replace wires. is on. Main burner orifice is plugged. -remove stoppage in orifice. Faulty valve. -replace. Pilot will not light. No spark at pilot burner -check if pilot can be lit by a match -check that the wire is connected to the push button igniter. -check if the push button igniter needs tightening. -replace the wire if the wire insulation is broken or frayed. -replace the electrode if the ceramic insulator is cracked or broken. -replace the push button igniter. Out of propane gas -fill the tank. Spark gap is incorrect -spark gap should be 0.150" to 0.175" (5/32" to 11/64" approx.) from the electrode tip and the pilot burner. To ensure proper electrode location, tighten securing nut (finger tight plus 1/4 turn). No gas at the pilot burner -check that the manual valve is turned on. -check the pilot orifice for blockage. -replace the valve. -call the gas distributor. Pilot goes out while Gas piping is undersized. -turn on all gas appliances and see if pilot flame flutters, diminishes or extinstanding; Main burner guishes, especially when main burner ignites. Monitor appliance supply working is in 'OFF' position. pressure. -check if supply piping size is to code. Correct all undersized piping. W415-0326 / C / 11.23.07 SYMPTOM PROBLEM TEST SOLUTION Flames are very ag-Door is ajar - fit door assembly into the lower support brackets and secure the four door gressive. latches. Venting action is too great. -restrict vent exit with restrictor plate, W500-0205. Main burner flame is Blockage in vent. -remove blockage. In really cold conditions, ice buildup may occur on the a blue, lazy, transpar-terminal and should be removed as required. ent flame. Incorrect installation. -refer to Figure 23 to ensure correct location of storm collars. Carbon is being de-Air shutter has become blocked -ensure air shutter opening is free of lint or other obstructions. White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber surfaces. -clean the glass with a recommended gas fireplace glass cleaner. DO NOT CLEAN GLASS WHEN HOT. If deposits are not cleaned off regularly, the glass may become permanently marked. Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" position. Wall switch is mounted upside down Remote wall switch is grounding. Remote wall switch wire is grounding. - reverse. - replace. - check for ground (short); repair ground or replace wire. Faulty valve. - replace. Flames are consist-Unit is over-fired or under-fired. ently too large or too small. Carboning occurs. -check pressure readings: Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3 turns and then placing pressure gauge tubing over the test point. Gauge should read 7" (minimum 4.5") water column for natural gas or 13" (11" minimum) water column for propane. Check that main burner is operating on "HI". Outlet pressure can be checked the same as above using screw (B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI". AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution. posited on glass, logs Flame is impinging o...

Otros modelos de este manual:
chimeneas - BGD48P (2.41 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría