Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Napoleon Fireplaces, modelo GD82NT

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 6.37 mb
Nombre del archivo: a273b373-5ddc-4c50-8950-643c3e060e1a.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


- 21 3/4” to top of fireplace opening. FIGURE 28 FIGURE 29 FIGURE 30 It is best to frame your fireplace after it is positioned and the vent system is installed. Use 2x4’s and frame to local building codes. Note: In order to avoid the possibility of exposed insulation or vapour barrier coming in contact with the fireplace body, it is recommended that the walls of the fireplace enclosure be “finished” (ie: drywall/sheetrock), as you would finish any other outside wall of a home. This will ensure that clearance to combustibles is maintained within the cavity. It is not necessary to install a hearth extension, but the fireplace should be raised to be flush with either the hearth or the finished floor. When roughing in the fireplace, raise the fireplace to accommodate for the thickness of the finished floor materials, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the removal of the hearth strip, which must be removed to access the firebox. Objects placed in front of the fireplace should be kept a minimum of 48” away from the front face. For convenience, the stand-offs have been shipped flat. Before framing, ensure the stand-offs are opened and screwed in place. IMPORTANT: The Park Ave. requires a minimum inside enclosure height of 72”. For temperature requirements, this area must be left unobstructed. It is recommended that the enclosure be ventilated at the top and bottom to circulate the hot air. Non-combustible finishing material (ie: cement board, brick, stone, tile) may be used to finish the front of the unit. 16 W415-0536 / C / 09.06.06 figure 32 MANTLE CLEARANCES 0 3 4 7 8 9 11 13 1 2 5 6 7 10 12 HEIGHT MANTLE MANTLE WIDTH Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clearance needed. Do NOT use the fireplace if any part has been under water. Call a qualified service technician IMMEDI ATEL Y to have the fireplace inspected for damage to the electrical circuit. If access to the control area is necessary before installation, remove the access panel. The access panel must be re-installed before operating the unit. It is necessary to hard wire this fireplace. Permanently framing the fireplace with an enclosure, requires the fireplace junction box to be hardwired. This fireplace must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 canadian electrical code in Canada or the ANSI/NFPA 70-1996 national electrical code in the United States. ELECTRICAL CONNECTION HARD WIRING CONNECTION Schematic IN OUT OFF PILOT ON AUXILIARY DEVICE L2 L1 FAN [HOT] TP TH AUX FAN LINE VALVE MOTOR AUTO MAN GAS figure 33 STUD 2" FIRESTOP SPACER 2" 5" 3" 2" 6" INSULATION SLEEVE 1" GAP FROM INSULATION SLEEVE 2" GAP FROM VENTING 4" TOP OF UNIT TOP OF FIREPLACE OPENING 11" 12" 10" 9" 8" SPACER STAND OFF 17 W415-0536 / C / 09.06.06 4. Place log #4 with the charred branch facing inward. Position the pin in log #4 into the hole on the right of log #2. 5. Place log #5 so the locating hole on the botttom of the log sits on the screw and spacer. 6. Finally, align the rectangular peg on log #6 with the notch on the front right portion of the burner. Optional Front Glass Door Latches Retainer Before the glass door can be removed, the optional front must be removed. The glass door is secured to the top front edge of the firebox. Pull the handles of the latches forward, then lift the hooks out from the slots in the door frame to release the top of the door. Next, pivot forward until the top edge of the door clears the front of the fireplace. Next gripping the sides of the door lift the door out from the retainer along the bottom of the door. LOG SHIPPING BRACKET Before installing the logs, you must first remove the log shipping brackets. Lift up to remove. door REMOVAL Log SHIPPING BRACKET FINISHING Decorative brick panels must be installed before the logs. See installation instructions supplied with the panel kit. Log Placement phazertm logs, exclusive to Napoleon Fireplaces, provide a unique and realistic glowing effect that is different in every installation. 1. Place the rear log #1 onto the locating studs along the back edge of the PHAZERAMIC™ burner. 2. Position log #2 in the 2 locating holes behind the andirons. 3. Place log #3, with the charred branch facing inward. Position the pin in log #3 into the hole on the left of the log #2. GLOWING EMBERS 2 3 4 1 figure 36 a-F figure 34 figure 35 Glowing embers are NOT recommended. The burner has been designed to achieve maximum glow without embers. 5 6 8 BLOWER REPLACEMENT The Napoleon PARK AVENUE comes equipped with a heat circulating blower. The blower is pre-wired and is controlled by the remote control supplied with the unit. For control details, see operation. Pg. . drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blow...

Otros modelos de este manual:
chimeneas - GD82PT (6.37 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría