Iniciar sesión:
Votos - 5, Puntuación media: 4 ( )

Manual de usuario Napoleon Fireplaces, modelo SLDVT-30NM

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 4.04 mb
Nombre del archivo: Lennox_Superior_SLDVT_Installation_506009-01.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


6. Position the door in front of the firebox opening with the bottom of the door held away from the fireplace (Figure 50). Hook the top flange of the door frame over the top of the firebox frame. 7. Let the bottom of the door frame swing gently in towards the fireplace ensuring that the gasket seats evenly as the door frame draws shut. Fasten the two latches located underneath the firebox floor to the door's vee-flange. Close both the latches securely. 8. Install the hood. Note the location of the three clips inside the top air channel above the door. The clips are equally spaced on the top surface of the air channel opening. Use a screwdriver to open the clips slightly if needed. Engage the back edge of the eyebrow into the clips to secure. Control Compartment Panel Hood Glass Door Header Spacing Top Standoffs Flush Nailing Flange 1/2” Nailing Flange 5/8” Nailing Flange Glass Door Spring Latch Only doors certified with the appliance shall be used. Seules des portes certifiees pour cet appareil doivent etre utilisees. CAUTION: DO NOT abuse glass door by striking or slamming shut. 1. To access the glass door securing latches, first open the lower control compartment door (Figure 50) by lifting and pulling the bottom panel forward. 2. Pull the latches forward and down to release them from the door channel. WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage – Do not scratch or handle roughly while reinstalling the glass door frame. • The glass door(s) of this appliance must only be replaced as a complete unit as provided by the manufacturer. Do not attempt to replace broken, cracked or chipped glass separately. • Do not attempt to touch the front enclosure glass with your hands while the fireplace is in use. WARNING Do not operate appliance with the glass front removed, cracked or broken. AVERTISSEMENT Ne pas utiliser l'appareil si le panneau frontal en verre n'est pas en place, est craque ou brise. SUPERIOR DIRECT-VENT GAS FIREPLACES • MODELS SLDVT-30/35/40/45 • INSTALLATION INSTRUCTIONS When the appliance is first lit, the entire flame may be blue and will gradually turn yellowishorange during the first 15 minutes of operation. If the flame remains blue, or if the flame is orange with evidence of sooting (black tip), the air shutter opening may need to be adjusted. If the air shutter opening is closed too far, sooting may develop. Sooting is indicated by black puffs developing at the tips of very long orange flames. Sooting results in black deposits forming on the logs, appliance inside surfaces and on exterior surfaces adjacent to the vent termination. Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening. To achieve a warm yellowish-orange flame with an orange body that does not soot, the shutter opening must be adjusted between these two extremes. 33 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS • Air shutter adjustment should only be performed by a qualified professional service technician. • Ensure front glass panel are in place and sealed during adjustment. CAUTIONS • Soot will be produced if the air shutter is closed too much. Any damage due to sooting resulting from improperly setting the air shutter is not covered under the warranty. • Theairshutterdoorandnearbyappliancesurfaces are hot. Exercise caution to avoid injury while adjusting flame appearance. Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Nat.Gas Propane Gas SLDVT-30/35 Closed 3/32 (2.362) SLDVT-40/45 Closed 3/32 (2.362) Adjustment Rod Up (Fully Open Position) Air Shutter Adjustment Rod Down min. air opening position) Burner Tube Adjustment Set-Screw Figure 54 -Burner Air Shutter Adjustment Figure 51 -Burner Flame Appearance Model SLDVT-30 and 35 Figure 52 -Burner Flame Appearance Model SLDVT-40 Figure 53 -Burner Flame Appearance Model SLDVT-45 1. Locate adjustment rod and adjust air shutter to the standard set- ting as shown in Figure 54 (adjustment rod is located in the lower control compartment). Note: Move the adjustment rod down to decrease air and up to increase. 2. Light appliance (follow lighting procedure on lighting label in con- trol compartment or see the Care and Operation manual). 3. Allow the burner to operate for at least 15 minutes while observing the flame continuously to ensure that the proper flame appearance has been achieved (see Figures51, 52 or 53 ). If the following conditions are present, adjust accordingly. • If flame appears weak or sooty, adjust the air shutter, incremen- tally, to a more open position until the proper flame appearance is achieved. • If flame stays lowered blue, adjust the air shutter, incrementally, to a more closed position until the proper flame appearance is achieved. 4. Leave the control knob (off/pilot/on) in the ON position and the burner OFF/ON switch OFF (...

Otros modelos de este manual:
chimeneas - SLDVT-30NM (4.04 mb)
chimeneas - SLDVT-30NM (4.04 mb)
chimeneas - SLDVT-30NM (4.04 mb)
chimeneas - SLDVT-30NM (4.04 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría