Iniciar sesión:
Votos - 4, Puntuación media: 4.8 ( )

Manual de usuario Napoleon Fireplaces, modelo BGD42P

Fabricar: Napoleon Fireplaces
Tamaño del archivo: 1.85 mb
Nombre del archivo: 31ff9eda-50ce-4108-830b-dbdd4b60b6b3.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


At this point, it must be strain relieved and insulated. The three slots on the blower mounting W415-0381 / E / 02.09.06 CHARCOAL EMBERS CHARCOAL LUMPS CHARCOAL EMBERS CHARCOAL LUMPS bracket allow ease of firebox base. adjustment when Slide the vibration reducing pad (A) into the clip (C) and up attaching the blower. VERMICULITE For a quiet running blower, do not allow the assembly to sit on the OPTIONAL BLOWER INSTALLATION against the threaded stud (B) at the other end. The blower must be able to be po sitioned entirely onto the pad. Tilt the blower onto its side. Slide it past the FIGURE 41 controls and into the clip (C). Secure to the threaded stud using the lock washer and wing nut provided. Ensure that the blower does not touch the fireplace base or the firebox. Attach the connectors from the black and white wires to the thermodisc and secure the thermodisc bracket to the securing stud at the bottom left of the unit using a lock washer and wing nut. Ensure that the thermodisc touches the firebox wall. FIGURE 42 Attach the connectors from the black and red wires to the blower. Attach and secure the variable speed switch using the nut provided. Plug the harness cord into the receptacle. CA B FIGURE 43 FIGURE 44 The wire harness provided in this kit is a universal harness. When installed, ensur cess wire is contained, preventing it from making con- tact with moving or hot objects Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run FIGURE 45 ings, causing irreparable da for approximately 30-45 minutes after the fireplace has been turned off. Use of easesDrywall dust will penetrate into the blower bear- ust betaken to prevent drywall dust from coming intocontact with the blower or its compartment. Anydamage resulting from this condition is not cov- FIGURE 46 the output of heat. ered by the warranty policy. ELECTRICAL INSTALLATION TO BE DONE BY A QUALIFIED INSTALLER and must be connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States. To safely install the fan, turn off the electricity first. If the fireplace was not previously equipped with a fan: route a grounded 2-wire, 60hz power cable to the junction box. At this point, it must be strain relieved and insulated. The wire harness provided in this kit is a universal harness. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects. To ease installation of the fan, remove the hinge screen and valve control door (lower louvres) from the base of the fireplace. W415-0381 / E / 02.09.06 OPTIONAL FAN INSTALLATION OPTIONAL FAN INSTALLATION GD36 THERMOSTATIC SENSOR CONTROL Position the vibration reducing pad into the clip and onto the threaded stud at the other end, piercing a hole into the pad. The fan assembly must be able to be positioned entirely onto the pad. Slide the fan assembly past the controls and into the clip. Secure using the lock washer and nut provided. FIGURE 47 Plug the harness cord into the receptacle. This optional kit is meant to be used only in conjunction with the GD65 Fan Kit, shown above, which may be ordered from your Wolf Steel / Napoleon dealer. With the thermostatic sensor option, the fan, when turned on, becomes thermally activated, and will automatically run approximately 15-30 minutes after the fireplace has been lit and for FIGURE 48 approximately 30-45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat. Unplug the power cord from the receptacle. Connect all wires as shown. Attach and secure the sensor assembly bracket to the securing stud located next to the receptacle/junction box at the bottom left of the unit using the lock washer and wing nut. Ensure that the thermodisc touches the firebox wall. Plug the power cord back into the receptacle. When installed, ensure that any excess wire is contained, preventing it from making contact with moving or hot objects. When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. FIGURE 49 After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. In both cases, open a window to sufficiently ventilate the room. Purge the gas line with the glass door removed. Assure that a continuous gas flow is at the burner before re-installing the door. A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly. B. Before operating smell ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría