Resumen del manual


The maximum allowable reduction in manifold pressure for Natural gas shall be from 3.5” w.c. (.872 kPa) to 2.8” w.c. (.697 kPa). The maximum allowable reduction in manifold pressure for Propane (LP) gas shall be from 10.0” w.c. (2.49 kPa) to 8.0” w.c. (1.99 kPa). For Canadian high altitude applications, this appliance is suitable for installation at elevations between 0 feet (0 m) and 4,500 feet (1,372 m) without change. Canada: This appliance is NOT to be installed in Canada. 22618-17-0308 Page 7 INSTALLATION INSTRUCTIONS - GENERAL SAFETY INFORMATION 1. This installation must conform with local codes or, in the absence of local codes with NFPA54. 2. Provide adequate clearances around the product for servicing and ensure there are no obstructions to the combustion air intake situated at the back of the heater. Refer to Page 15, Figures 7 through 10. 3. The appliance must be installed on a flat, solid continuous surface (i.e. wood, metal, concrete). Please Note: Rough or uneven surfaces can cause vibration or humming in the heater. 4. The Mantis Power-Vent High-Effeciency Fireplace can be installed in a wide variety of ways and will fit nearly any room layout. It may be installed in a recessed position, framed out into the room, or across a corner. For installation options refer to page 15. 5. This appliance (Insert and Freestanding Models) needs to be installed in such a way that the heater can be removed at all times to service the heater exchanger and flue fan located in the rear section of the heater. Note: Under no circumstances should the appliance be installed under conditions which would not allow for easy removal of the appliance to carry out routine inspection and service to the appliance, to do so will void the warranty. Note: On Single Wall flue pipe installations (imitation zero clearance fireplace) a minimum of 2” (50.8 cm) clearance must be provided at the rear of the heater to enable the heater to get sufficient combustion air to the air inlet located at the rear of heater. Refer to installation instructions on page 15, Figures 7 through 10. Note: Where a mantel surround is being used on insert installations and zero clearance fireplace installations, the combustion air intake slot located in the top mantel surround must have no obstructions to allow combustion air to enter through the slot to the combustion air inlet located at the back of the heater. SPECIFICATIONS Model PV28SV50 Input BTU/HR (KW/H) 19,000 Rear - 9,000 Front Height 25 1/8” Width 28 3/16” Depth 17 5/8” Gas Inlet (Pipe) 3/8” Flair Electrical -Unit has a 5’ (1.5 m) 3 pronged cordset for connection to an approved 115 VAC 60 Hz maximum AMPs - 5A wall receptacle. Accessories Part Number Description PV-2H Top Cover - Slim Assembly PV-4H Top Cover - Short Assembly PVPK Pedestal Kit PVE-1 6” Surround Assembly PVSH Rear Shroud TRW Wall Thermostat - Wireless Remote FRBTC Battery Operated Remote w/Thermostat FRBTP Battery Operated Remote w/Programmable Thermostat TMV2 Two-Stage Thermostats CIPFP-1 Floor Pad Kit CIFPB-1C Corner Floor Pad Kit PVVK24H Direct Vent 24” Vent Kit PVVK48H Direct Vent 48” Vent Kit PVVK-SH Single Flue Horizontal Vent Kit PVVK-SV Single Flue Vertical Vent Kit PVVK-CFA Flex Vent Kit PVCT Colinear Transition PVVTC Vertical Termination Cap - 1.5” PVCA Colinear Adapter Page 8 22618-17-0308 CLEARANCES FOR DIRECT VENT 1. Pick a location on a wall with a clear space in the room. In selecting a location for installation, it is necessary to provide adequate accessibility clearances for servicing and proper installation. Be sure to locate the unit close enough to a 110 VAC wall receptacle to properly power appliance. 2. When facing the front of the furnace the minimum clearances from casing to combustible construction are 0” (0 mm) on top, 0” (0 mm) on each side, recommend 4” (102 mm) on sides for servicing and 0” (0 mm) from the floor, 0” (0 mm) to rear wall and 40” (1,016 mm) from Mantis top to ceiling. 3. The minimum distance from the center of the vent cap to the nearest outside corner or obstruction is 12” (305 mm). 4. The minimum wall depth is 4” (102 mm) and the maximum is 48” (121.92 cm). The vent terminal of a direct vent appliance, with an input of 50,000 BTU (14.6KW) per hour or less shall be located at least 9” (229 mm) from any opening through which flue gases could enter a building. The bottom of the exhaust vent terminal and the air intake shall be located at least 12” (305 mm) above grade and must be vented outside. WARNING: The nearest point of the vent cap should be a minimum horizontal distant of six (6) feet (1.83 m) from any pressure regulator. In case of regulator malfunction, the six (6) feet (1.83 m) distance will reduce the chance of gas entering the vent cap. Installation on Rugs and Tile If this appliance is to be installed directly on carpeting, tile, or other combustible material, other than wood flooring, the appliance shall be installed on a metal or wood panel extending the full width and de...

Otros modelos de este manual:
chimeneas - BP)-1 (4.33 mb)
chimeneas - CP (4.33 mb)
chimeneas - GN (4.33 mb)
chimeneas - PV-28SV50-BN (4.33 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría