WALL SURFACE OR VINYL SIDING KIT FLUE PIPE CUT 2 .” BEYOND EXTERNAL WALL SURFACE OR VINYL SIDING KIT Figure 3B 7. Remove outside mounting plate with tube attached from wall. Mark and cut the extra length of the 6 5/8” (168mm) diameter tube from the opposite end. Do not crimp or enlarge tube. 8. Attach the 4” (102mm) diameter flue outlet tube onto the rigid venting system or directly to fireplace. Ensure the 4” (102mm) diameter flue outlet tube is placed as far as possible onto the rigid venting system. Mark the 4” (102mm) diameter flue outlet tube 2 1/2” (64mm) beyond the vinyl siding kit or wall. See Figure 3B. Remove the 4” (102mm) diameter flue outlet tube from rigid venting system. When installing directly to fireplace, tape gasket needs to be used. 9. Mark or wrap tape completely around the tubes at the marked points to help in making a true cut. Do not crimp or enlarge tubes. 10. From outside: Push the 6 5/8” (168mm) diameter inlet tube/mounting plate onto end of rigid venting system to correct position. Fasten the outside mounting plate to the vinyl siding kit or wall with (4) 10 x 1 1/2” screws. (Ensure upward slope). 11. From inside: Attach the inlet tube to the collar on the back of the fireplace (or the rigid venting system) using (3) self tapping screws. 12. Seal the 4” (102mm) diameter flue outlet tube. Follow instructions and diagram (Figure 4). 13. Fasten 4” (102mm) diameter flueoutlet tube in place.Do not“twist” the flue outlet tube into the fireplace collar (or rigid venting system). Hold the tube by the seam and push in using a perpendicular “rocking” motion. This ensures the seam on the tube stay intact. 14. Fasten vent cap end using (3) 10 x 1/2” screws to mounting plate. Sealing 4” (102mm) Diameter Flue Outlet Tube DO NOT PLACE OVERLAPPED SECTION OVER VENT CAP END APPLY SEALANT ON THE INSIDE 1” Figure 4 THESEAMINTHETUBE Note: Tape gasket to be applied prior to installing to fireplace flue outlet tube only. Tape gasket should not be used when mating the flue outlet tube to a rigid venting system. Page 28 23552-1-0607 23552-1-0607 Page 29 Follow correct option according to venting method. Connecting Directly to Fireplace If the air inlet and flue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4” (102mm) flue outlet tube. Peel the paper off the self-adhesive gasket and then wrap it around the end of the tube (if tube was cut, it is recommended to use cut end) as shown in Figure 4. Pull the gasket tight at all times while wrapping it around tube. The gasket ends should align, to form a complete seal. The overlapped section should NOT come in contact with the seam in the tube. Apply high temperature sealant to the opposite end of the tube (on the inside of the tube). The end with the gasket will attach to the back of the unit. Continue with Step 13. Connecting to Rigid Vent System If the air inlet and flue outlet tubes are to be connected to a rigid venting system (and not directly to the back of the unit), then do not use the gasket provided. High temperature sealant should be applied to the outside of the 4” diameter (102mm) flue outlet tube (if tube was cut, it is recommended to use cut end) and to the inside of the tube on the end that connects to the vent cap. Continue with step 13. PARTS LIST INDEX NUMBER PART NUMBER DESCRIPTION 1 DV769 Vent Cap Assembly 2 19193 Outside Mounting Plate 3 19194 Air Inlet Tube 4 DV524 Flue Outlet Tube 5 19196 Firestop/Thimble Assembly 6 20527 Gasket DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued) Page 30 23552-1-0607 INSTALLATION 1. Unpack vent components and check that all items are included. 2. Check to see that the vent spacer springs are located around the flue vent at 8" and 12" intervals along its length. See Figure A. If not, stretch the spacer springs to about 15" long and wrap them around the flue, then interlock the ends of each spring about 2". See Figure B. Maintain equal distance between spring spacers. 3. Remove the 6-." dia. Vent collar from the fireplace. Replace this collar with the 7" dia. Flex Vent adapter collar provided with the vent kit. 4. Slide the Flex Vent flue pipe into the Outer Flex Vent pipe. 5. Install the Wall Firestop/Thimble assembly as required through the wall. Refer to the venting charts in the fireplace manual to determine the proper height and size of the vent opening. The minimum opening should be 9" wide by 11" high. The minimum combustible clearance from the horizontal vent is 1" from sides and bottom, and 3" above the vent pipe. See Figure D. 6. In most cases, after determining the length of the vent that is needed, it may be easier to install the flue and outer vent pipes to the Termination Cap first, then from the outside, feed the venting through the wall to the fireplace. 7. If the venting is to long, trim off any excess vent before attaching the vent end connectors. 8. Attach the Termination Cap to the o...
Otros modelos de este manual:chimeneas - DVD36FP3 (3.9 mb)
chimeneas - DVD32FP3-1, DVD36FP3-1, DVD42FP3-1, DVD48FP3-1,DVD32FP5-2, DVD36FP5-2, DVD42FP5-2, DVD48FP5-2 (3.9 mb)
chimeneas - DVD42FP3 (3.9 mb)
chimeneas - DVD48FP3 (3.9 mb)