Parts having to be removed for servicing must be replaced prior to operating this electric fireplace again. 8. Do not use outdoors. 9. This heater is not intended for use in bathrooms, laundry areas or similar indoor locations. Never use this appliance near a bathtub or other water container. 10. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic areas and where it will not be tripped over. 11. To disconnect this appliance, turn controls to the off position and remove plug from outlet. 12. Connect to properly grounded outlets only. 13. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause electric shock, fire or damage to the appliance. 14. To prevent fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, such as a bed, where openings may become blocked. 15. This appliance has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored. This electric fireplace should not be used as a drying rack for clothing, Also, do not have Christmas stockings or decorations hung on or near it. 16. Use this appliance only as described in this manual. All other uses not recommended by the manufacturer may cause fire, electric shock, or injury. 17. Avoid the use of an extension cord because it may overheat and cause a fire hazard. However if you must use an extension cord, the cord shall be 1.0 mm2 ,1900 Watts. The extension cord must be a three wire cord with grounding type plug and cord connector. 18.SAVE THESE INSTRUCTIONS. LOCATING YOUR ELECTRIC FIREPLACE Your new freestanding electric fireplace may be installed virtually anywhere in your home. However when choosing a location for your new electric fireplace, ensure that the general instructions are followed. For best effect results, install the electric fireplace out of direct sunlight. CLEARANCE TO COMBUSTIBLES ELECTRICAL CONNECTION Back…………………………0mm Sides……………..…………0mm Floor……………. .…………0mm Top………………. .…………610mm Back…………………………0mm Sides……………..…………0mm Floor……………. .…………0mm Top………………. .…………610mm WARNING: Electrical outlet wiring must comply with local building codes and all other applicable regulations to reduce the risk of fire, electrical shock and injury. WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a qualified service technician to A 10 AMP, 220 Volt,50Hz circuit with a properly inspect the fireplace and replace grounded outlet is required. Preferably, the stove will any part of the electrical system if be on a dedicated circuit. Other appliances on the necessary. same circuit may cause the circuit breaker to trip or the fuse to blow when the heater is on operation. ELECTRICAL SPECIFICATIONS The unit comes standard with a 6’ (1828mm) long three wire cord exiting from the rear of the fireplace. Plan the installation to avoid the use of an extension cord. If an extention cord must be used, it must be a minumum 1.0 mm2 three wire with grounding type plug connector and rated no less than 1900 Watts. Voltage………………220 VAC/50Hz Total Amps…………..6.5 Amps Total Watts…………..1350 Watts Heater Ratings………1200 Watts SERVICE INSTRUCTIONS WARNING: Disconnect power before 7. Install the new light bulb(s) by holding the socket attempting any maintenance or cleaning and screwing them. 8. Reinstall the log set and screen. Follow the above to reduce the risk of fire, electrical shock procedure in reverse order. or personal injury 9. The diameter of the pilot light bulb is 5mm. If the pilot REPLACING LIGHT BULBS light bulb need to be replaced, follow steps 1,2,3,4 above. Then use the pilot light bulb socket w/wiring This fireplace uses two clear 220 Volt, 60 Watt, E-14 socket base light bulbs (small base, chandelier candle type).The assembly replace the primary pilot part, and connect 60 Watt bulbs are located under the log set/ember bed. For wires according to primary connection . Then follow convenience, if one of the bulbs burns out, it may be a good step 8 above. idea to replace both of the light bulbs. 1. Turn off power to the unit by unplugging the power cord. WARNING: Do not exceed 60 2. Let fireplace cool if it has been operating. Watts per bulb. Use of higher 3. Remove the two fixing self-tapping screws on the screen. rated bulbs may result in a fire Pull the screen upward a little bit, and then out. causing property damage and 4. Remove the two screws that secure the log set in position. personal injury. 5. Examine the bulbs to determine which bulbs need to be replaced. 6. While holding the socket, unscrew the defective bulb (s). 4 5 MAINTENANCE OF MOTORS The motors used on the fan and flame generator assembly are prelubricated for extended bearing life and require no further lubrication. However, periodic cleaning/vacuuming of the fan/heat...
Otros modelos de este manual:chimeneas - V50TYLA-BC (4.79 mb)
chimeneas - V50TYLA-C (4.79 mb)
chimeneas - V50TYLA-DO (4.79 mb)
chimeneas - V50TYLAR-BC (4.79 mb)