Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Majestic, modelo STR33

Fabricar: Majestic
Tamaño del archivo: 1.59 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


NOTE: The size of the insulation and stainless steel plate must be within limits stated above and covers all combustible framing material. Fig. 28 Recessed installation. FP1608Hearth Extension Hearth Extension Noncombustible Material (if desired) Insulation with Minimum R Value of 2.75 Recessed Installation - STR33/36, CVR36 Only 6” (152 mm) Minimum 7412961 STR/CVR Series Woodburning Fireplaces Installing Line for Gas Logs Majestic Fireplaces are designed to accept a 1/2" (13 mm) gas line for installation of an approved gas appliance. (CFM Corporation manufactures a wide variety of gas logs for use in Majestic fireplaces.) Be sure to have the appliance installed in accordance with building codes. Gas connection may enter from either left or right side of the fireplace. Locate appropriate gas line in the outer casing of fire place and remove insulation from gas line tube. (Fig. 29) From inside the fireplace, locate the knockout on the firebrick -- be sure you are on the appropriate or "gas line" side of the fireplace. Using a flat bladed screwdriver or small chisel and hammer, carefully tap around the knockout until it loosens and falls out. Install 1/2" (13 mm) certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube. NOTE: Gas pipe should not come in contact with any wood structures until it has reached a point at least 1" (25 mm) away from fireplace side. Note: Local codes may require removal of flue damper when installing any type of gas appliance in a fireplace. NOTE: When installing an ANSI Z21.11.2 ventless appliance, the fninshing material used for the mantel must be rated at 250°F or greater. BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr. Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburning Fireplaces (Draft No. 4, August 1993). Decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 (latest edition). 1" FP716 Fireplace Top View Hole in Outer Casing Gas Line Tube Supply Line Repack Insu- lation Ceramic Knockout (Both Sides on STR) Hole in Outer Cas- ing Fig. 29 Gas line access. CAUTION: WHEN USING DECORATIVE GAS APPLIANCE, FLUE DAMPER MUST BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED. WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE WITH THE CHIMNEY REMOVED. WARNING: WHEN INSTALLING AN UNVENTED GAS LOG SET, THE CFM CORPORATION MODEL AH3244BK OR AH3244PB 4" ADJUSTABLE HOOD MUST BE USED. If installing an unvented gas log set, refer to statement below: Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace. 741296119 STR/CVR Series Woodburning Fireplaces 5a 1, 2, 3 4a 6 7 a b c d 8 9 10 11 5b 4b e 12 13 14 961 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. CVR36/42 SERIES Ref. Description CVR36 CVR42 1. Flue Damper RP102 RP161 2. Damper Actuator 7548170 7548169 3. Damper Handle Push Nut 7512903 7512903 4a. Screen Rod Assembly - Side (two per fireplace) 3030126 3032112 4b. Screen Rod Assembly - End 7554342 7554342 5a. Screen Assembly - Side (four per fireplace) 7554338 7554340 5b. Screen Assembly - End 7554340 7554340 6. Screen Pulls (four per fireplace) 5584139 5584139 7a. Firebrick -Hearth 3102103 3101105 7b. Firebrick - Side Ash Lip (two per fireplace) 3102102 3101103 7c. Firebrick - End Ash Lip 3101104 3101104 7d. Firebrick - Side 3079147 3079147 7e. Firebrick - Side Filler (two per fireplace) 3079148 3079148 8. Top Brick Retainers (two per fireplace) 3079130 3079130 9. Cable Clips (twelve per fireplace) 7512135 7512135 10. End Panel (Glass and Extrusion) 3080145 3080145 11. Tempered Glass (two per fireplace) 20000399 20000399 12. Nailing Flange (four per fireplace) 5069164 5069164 13. Basket Grate 2056100 2058100 14. O.S.A. Assy. 20003212 20003212 20 7412961 STR/CVR Series Woodburning Fireplaces 961 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 5 1, 2, 3 4 6 7 a b cd 8 9 1011 12 STR33/36/42 SERIES Ref. Description STR33 STR36 STR42 1. Flue Damper RP102 RP102 RP161 2. Damper Handle 7548170 7548170 7548169 3. Damper Handle Push Nut 7512903 7512903 7512903 4. Screen Rod Assembly (two per fireplace) 3049122 3030126 3...

Otros modelos de este manual:
chimeneas - CVR36 (1.59 mb)
chimeneas - CVR42 (1.59 mb)
chimeneas - STR33 (1.59 mb)
chimeneas - STR36 (1.59 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría