|
Resumen del manual
. . . . . . . . . . . . Gas Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation Company. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Engineer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Corgi Reg No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEALER AND INSTALLER INFORMATION This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance commissioning Checklist is fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid during the second year, to the extent permitted by law, if the annual service recommended in the Instructions for Use has been completed by a Corgi registered engineer, and a copy of the service visit report is available for inspection by a Gazco engineer. 3 USER INSTRUCTIONS 1. GENERAL 1.1 Installation and servicing must only be carried out by a competent person. 1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the databadge located on a chain beneath the control valve. 1.3 Ensure that curtains are not positioned above the fire, and that there is a 300mm minimum clearance between the sides of the fire and any curtains. 1.4 This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your local Gazco dealer. Please consult with your local Gazco dealer if you have any questions. In all correspondence always quote the Model Number and Serial Number. 2. LIGHTING THE APPLIANCE 2.1 Locate the control valve on the appliance. There are two control knobs on the valve, the right hand knob controls the pilot ignition and the left hand knob controls the main burner. 2.2 If your appliance has already been upgraded to battery remote control, please refer to the instructions provided with the upgrade to operate the remote control. The following instructions will work for either situation. 2.3 Ensure that the left-hand control knob is pointing to off ( ). 2.4 Ensure that the right hand control knob is pointing to off ( ). 2.5 Press in the right hand control knob and rotate it anti- clockwise until a click is heard (keep pressing in) and the knob is pointing to pilot ( ). The pilot should now light. If the pilot has not lit, repeat the procedure until it does. 2.6 Keep the control knob pressed for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedures until it does. 2.7 If the pilot will not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased. 2.8 Turn the right hand control to point to main burner ( ). The appliance can now be controlled using the left hand control knob. 2.9 Turn the left hand control knob to point to low fire ( ), the main burner will light on low. The burner can now be controlled between low and high settings. Turn the control knob anticlockwise to increase the flame height and clockwise to decrease the flame height. THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES. 3. TURNING THE APPLIANCE OFF 3.1 To turn the fire off, locate the control valve, turn the left- hand control knob until it points to off ( ). The main burner will go out leaving the pilot burning. 3.2 To turn the pilot off, locate the control valve, turn the right hand control knob until it points to off ( ), the pilot will go out. 3.3 IF THE FIRE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RE-LIGHT. 3.4 After the fire has been turned off, the gas left in the burner will continue to burn, causing a crackling or popping noise. This is quite normal and will last up to one minute. 4. LIGHTING THE FIRE WITH A MATCH If the pilot does not ignite as described in Section 2, it may be lit with a match. 1 4.1 Press in the right hand control knob and rotate it anti- clockwise until a click is heard (keep ...
Otros modelos de este manual:chimeneas - Chamonix & Aspen (P)8119**UC (602.53 kb)
chimeneas - Chamonix & Aspen (P)8120**UC (602.53 kb)
chimeneas - Chamonix & Aspen (P)8127**UC (602.53 kb)
chimeneas - Chamonix & Aspen (P)8128**UC (602.53 kb)