Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Connecting Optional Wall Switch or Thermostat 1. Use 18 awg, two-wire cable, 20 feet maximum length. 2. At one end of the cable, connect both wires to the wall switch or thermostat. At the other end, connect one wire to TP/TH and one wire to TH. The color of the wires does not matter. SKYTECHOFFONREMOTEFIREPLACEREMOTEFP2113install remote ELECTRICAL WIRING (Milli-volt) Connect Remote Receiver THESE INSTRUCTIONS SUPERSEDE THE SECTION ENTITLED “HEARTH MOUNT” IN THE MILLI-VOLT HAND-HELD REMOTE INSTRUCTIONS SUPPLIED WITH THE REMOTE. 1. Remove bottom louver door. 2. Connect the remote connectors located in the unit. 3. Apply Velcro® pads with self-adhesive backing to bottom of remote receiver and to floor of compartment behind access panel. 4. Attach remote receiver to firebox with Velcro® pads. Control switch must face forward. Velcro® Pad Remote Receiver NOTICE Do not place remote in combustion chamber. Velcro Pad Figure 17 - Install Remote Receiver FP2113 Check System Operation The millivolt system and individual components may be checked with a millivolt meter having a 0-1000 mV range. Conduct each check shown in chart below by connection meter test leads to terminals as indicated. Connect Meter Switch or Meter Check To Leads to Thermostat Reading Test Test Terminals Contacts Should Be A Complete 2 & 3 Closed Closed System B Thermopile 1 & 2 Open Open Output A. Complete Millivolt System Check (“A” Reading - Thermostat contacts CLOSED - Control Knob “ON” - Main burner should be come ON) a. If the reading is more than 100 millivolts and the automatic valve still does not come on, replace the control. b. If the closed circuit reading (“A” reading) is less than 100 milli-volts, determine cause for low reading, proceed to Section B below. B. Thermopile Output Reading Check (“B” Reading - Thermostat contacts OPEN - Main burner OFF) 1. Check gas pressure to the unit. If gas pressure is within minimum and maximum on data plate, then check pilot voltage, 325 millivolts minimum. If the minimum milli-volt reading is not obtainable, replace pilot. LOG PLACEMENT Before you begin — This unit is supplied with a set of three ceramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fibers. WARNING WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance. Never add additional logs or embellishments such as pine cones, vermiculite or rock wool to the heater. LG588 CFX24 logs CAUTION DO NOT sprinkle volcanic rock on the logs or around the pilot or the main burner. This may cause sooting. Only place volcanic rock on the floor of the fireplace. During initial operation of the new heater, burning logs will give off a paper burning smell and orange flames will be present. Simply open the windows for a few hours to vent the odor. Right Log #1 Left Log #2 Proper installation sequence (CFX24) Figure 18 1. Install the rear log (#3) on back of burner. 2. Install the right log (#1) on burner pins on right side of burner. 3. Install the left log (#2) on burner pins on left side of burner. Rear Log #3 Burner Pins Burner Pins Figure 18 - Log Placement CFX24 LG588 LG589CFX32 logs LOG & ROCKWOOL PLACEMENT Rear Log #3 Proper installation sequence (CFX32) Figure 19 1. Install front right log (#1) on two pins on right side of burner. 2. Install left front log (#2) on two pins on left side of burner. 3. Install back log (#3) on back of burner. 4. Install right middle log (#4) on two pins on burner. Rest right end of right middle log on the right front log. 5. Install left middle log (#5) on two pins on burner. Rest left end of left middle log on left front log. Left Middle Log #5 Left Front Log #2 Right Middle Log #4 Pins Right Front Log #1 Pins Pins Figure 19 - Log Placement CFX32 Pins LG589 Place rock wool After installing logs, pull apart dime-size pieces of rock wool. Place rock wool evenly over burner ports. Wash hands after installing rock wool. Itching may occur. CAUTION • Use only rock wool provided with log set. • Do not add additional rock wool. • Place rock wool on burner ports only. • Keep air gap between rear log and burner CLEAN. Dime Size Rock Wool LG590CFX rock wool Figure 20 - Rockwool Installation LG590 flame appearance Flames from the pilot, front and rear burner should be visually checked as soon as the heater is installed. In addition, periodically check the flames visually during operation. Check the pilot flame The pilot flame must always be pre...

Otros modelos de este manual:
chimeneas - CFX24 (2.65 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría