|
Resumen del manual
C. Turn off all electric power to the appliance. D. Do not use this appliance if any part of it has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any pat of the control system and any gas control that has been under water. LIGHTING ELECTRONIC IGN 1. STOP! Read the safety information above. 2. Set thermostat to lowest setting. Then turn switch to off position. 3. Turn off all electric power to the appliance. 4. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand. 5. Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas STOP! Follow “B” - What to Do if You Smell Gas above. If you do not smell gas, go to the next step. 6. Turn on all electric power to appliance. 7. Set thermostat to desired setting or turn RS-OFF-ON rocker switch to “ON”. 8. If the appliance will not operate, follow the instructions To Turn Off Gas below, and call your service technician or gas supplier. ONOFFPILOTLOHI ............................................ Figure 25 - Electronic Gas Valve TO TURN OFF GAS 1. Turn RS-OFF-ON rocker switch to “OFF”. 2. Turn off all electric power to the appliance if service is to be performed. 3. Close lower door. CLEANING and MAINTENANCE WARNING Turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season. Thermocouple .................................. BURNER, PILOT AND CONTROL COMPARTMENT Keep the control compartment, logs and burner areas surrounding the logs clean by vacuuming or brushing at least twice a year. Make sure the burner porting, pilot air opening and burner air openings are free of obstructions at all times. PILOT FLAME The flames from the pilot should be visually checked as soon as the heater is installed and periodically during normal operation. The pilot flame must always be present when the fireplace is in operation. Figure 26. The pilot flame has three distinct flames, one engulfing the thermopile, one engulfing the thermocouple and the other reaching to the main burner. BURNER Inspect area around the injector. Remove any lint or foreign material with a brush or vacuum. BURNER FLAME The flames from the burner should be visually checked as soon as the heater is installed and periodically during normal operation. In normal operation, at full rate, and after operating for about 15 to 30 minutes, the flame should be yellow and slightly taller than the rear log. Figure 27 NOTE: The type of installation, vent system configuration and wind effects may cause the flame patterns to vary. Thermopile FP2030 Figure 26 - Pilot Flame LG663BBV SBV400 log flame Figure 27 - Burner Flame Appearance LG663 CLEANING and MAINTENANCE VENT SYSTEM The fireplace and venting system should be inspected before initial use and at least annually by a qualified field service person. Inspect the external vent cap on a regular basis to make sure that no debris is interfering with the airflow. Inspect entire venting system to ensure proper function. LOGS Leave logs installed in the fireplace for cleaning. Vacuum surface of the logs with a brush attachment. If logs must be removed for cleaning, handle carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, wash gently with soap and water. Vacuum surface of logs with brush attachment or brush logs with a soft bristle brush (i.e. clean, dry paintbrush). To place logs back in the fireplace, refer to “Log Placement” found in the Final Installation section. NOTE: Do not use cleaning fluid to clean logs. ROCK WOOL Replace or add rock wool as required following installation instructions in the Final Installation section of this manual. 4a4b4c ...................................................... 123567 REPLACEMENT PARTS FIREBOX COMPONENTS REPLACEMENT PARTS FIREBOX COMPONENTS Item Description Qty. BBV400 SBV400 SBV500 1. Pull Screen Panel 2 61D0001 61D0001 61D0003 2. Refractory Side 2 n/a 61D0101 61D0101 3. Refractory Back 1 n/a 61D0102 61D0102 4a. Left Refractory 1 n/a 62D1015 62D2015 4b. Middle Refractory 1 n/a 62D1016 62D2016 4c. Right Refractory 1 n/a 62D1017 62D2017 Optional Field Installed Accessoriesd 5. Firebrick Assembly 1 F400BBVW n/a n/a 6. Outside Air Kit 1 OAC4 OAC4 OAC4 7. Black Glass Door Assembly 1 GD36BA GD36BA GD36BA 7. Polished Brass Glass Door Assembly 1 GD36PBA GD36PBA GD36PBA 7. Stainless Glass Door Assembly 1 GD36SSA GD36SSA GD36SSA LG664BBV SBV400 log parts321 LOGS Item Description Qty. BBV400 SBV400 SBV500 1. Rear Log - #1 1 54D0121 54D0181 54D0339 2. Top Right Log - #2 1 54D0147 54D0116 54D0361 3. Top Left Log - #3 1 54D0146 54D0115 54D0360 REPLACEMENT PARTS STANDING PILOT - MILLIVOLT CONTROL 123456781012, 13 2T 2I2C 9 11 .................................................... REPLACEMENT PARTS STAN...
Otros modelos de este manual:chimeneas - B-VENT BBV400 (2.22 mb)
chimeneas - B-VENT SBV400 (2.22 mb)