Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Regency, modelo DT-400CMP

Fabricar: Regency
Tamaño del archivo: 973.7 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


5. Reinstall the outlet box. 6. Insert the blower plug into the top outlet. (The bottom outlet is unused on millivolt units, while the burner control circuit plugs into the bottom outlet on electronic units.) IMPORTANT: Ground lead must be connected to the green screw located on the outlet box. See Figure 45. Failure to do so will result in a potential safety hazard. The appliance must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70( latest edition). (In Canada, the current CSA C22-1 Canadian Electrical Code.) 1. If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. 2. 120V, 60Hz – Less than 3 amps. BK Junction Box Transf. 120 V. 24 V Factory Wired Field Wired BL Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK-100 and FBK-200 Kits R W BL OPT BLOWER G W *OPTIONAL ACCESSORY SWITCH 120 VAC. BK W Gas Valve B R IGNITER PILOT ASSEMBLY Break Off Tab BK G *Blower speed control switch is provided in FBK200 blower kit. Outlet Box Green Ground Screw Hot side of Outlet Schematic Representation Only **ON/OFF Switch (Integralwith Gas Valve) **Leave the ON/OFF switch, which is integral with the gas valve, in the ON position. OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE RECEIVER Red pigtail Black pigtail White Wire to Opposite Side G Figure 45 FBK-250 Blower Kit (See Figure 46) FBK-250 Blower Kit (See Figure 46) 1. Route a 3-wire, 120Vac 60Hz 1ph power line to the lower right rear corner of the appliance. 2. Remove the outlet box by removing two screws. 3. Connect the black supply wire to both of the outlet box' pigtail leads and the white supply wire to the common terminal of the outlet box as shown in Figure 46. 4. Connect the ground supply wire to the outlet's green ground screw. 5. Reinstall the outlet box. 6. Insert the kit-provided module plug into the top outlet. (The bottom outlet is unused on millivolt units, while the burner control circuit plugs into the bottom outlet on electronic units.) 7. Insert the blower plug into the module's receptacle. Figure 46 1. If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. 2. 120V, 60Hz – Less than 3 amps. BK Transf. 120 V. 24 V Factory Wired Field Wired BL Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK-250 Kits R WH BL OPT BLOWER G W 120 VAC. BK W Gas Valve B R IGNITER PILOT ASSEMBLY BK G Outlet Box Green Ground Screw Hot side of Outlet Schematic Representation Only *ON/OFF Switch (Integral with Gas Valve) White Wire To OppositeSide Optional FBK-250 Module *Leave the ON/OFF switch, which is integral with the gas valve, in the ON position. G OPTIONAL APPLIANCE-MOUNTED ON/OFF SWITCH OR OPTIONAL WALL SWITCH OR OPTIONAL THERMOSTAT OR OPTIONAL REMOTE RECEIVER NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Gas Stub . ." x . ." Flare Shut-Off Valve . ." Flex Tubing . ." NPT x . . Flare Fitting . ." Nipple . ." Union . ." Close Nipple . ." Shut-Off Valve . . x . . " Reducer Gas Valve Optional Gas Flex Line Connector Figure 47 -GAS CONNECTION Step 6. CONNECTING GAS LINE Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 47 illustrates two methods for connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary depending on locality. Installation must be in compliance with local codes. These appliances can be equipped with a gas flex line for use (where permitted) in connecting the unit to the gas line. The gas flex li...

Otros modelos de este manual:
chimeneas - DT-400CEP (973.7 kb)
chimeneas - DT-400CEN (973.7 kb)
chimeneas - DT-400CEP (973.7 kb)
chimeneas - DR-400CEN (973.7 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría