INSIDE: Attach and secure the flex liners to the vent connection assembly using the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust collar. FIGURE 3 FIGURE 4 VENT CONNECTOR EXTENSION RESTRICTOR PLATE STUDS FIGURE5a-b 5. Reaching in through the insert, manoeuvre the vent connection assembly through the openings in the firebox top, taking care not to damage the gasket. In case of a low ceiling fireplace, the extension should be removed and reinstalled after the vent connection is secured to the firebox. Attach the restrictor plate to the centre stud and secure the assembly using the three studs and .-20 hex nuts. 4. Detach the two screws from the back of the firebox and remove the panel, as illustrated. W415-0224 / D / 01.15.04 WALL SWITCH / THERMOSTAT GAS INSTALLATION FINISHING For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fireplace insert to the wall switch / millivolt thermostat. The recommended maximum lead length de pends on the wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Do not connect either the wall switch, thermostat or gas valve to electricity (110 VOLTS). Install suitable supply piping connection to the 3/8" flex connector supplied (as per local gas codes). FIGURE 6 The insert may now be pushed into its final position inside the wood-burning fireplace. Secure the insert to the fireplace using perforated strapping attached to the two securing holes on either side of the unit as shown. We recommend that the trim be installed before the unit is placed into its final position. SECURING HOLES FIGURE 7 In order to close off the fireplace opening or if the opening is larger than the 3- or 4-sided aluminium extrusion trim kits, it is recommended to reduce the opening using a noncombustible material such as ceramic tile, marble, etc or the GIZBP6-3 or GIZBP6-4 backer plate kits. The outside edge of the backer plate is finished off with gold trim included in each kit. A deluxe flashing kit complete with marquis trim may also be used to complete the installation. These flashing and trim combinations are available in 6 and 9 inch widths as well as many finishes to accent any room decor. Mounting brackets, GIZBRKT, are required to install the deluxe flashing. Detailed installation instructions are included with each kit. If this unit is being installed into an existing wood burning, zero clearance fireplace, then be aware of this precaution: Any circulation air opening may be covered (with noncombustible material) but not sealed! ALUMINIUM EXTRUSION TRIM KIT INSTALLATION The insert can be equipped with either a 3- or 4-sided trim kit to finish off the fireplace opening. Slide the trim assembly over the keyholes (2 per side) and drop into place. If installing the optional 3- or 4-sided backer plate (GIZBP6-3 or GIZBP64), it must be hung prior to the trim kit installation using the same keyholes. FIGURE 9 FIGURE 8 FIRE VIEWING DOOR FIGURE 11 VALVE CONTROL DOOR FIGURE 10 LOOSEN SCREWS SLIDE TO ADJUST To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and re-tighten screws. There is also a very slight in/out adjustment that can be made. Note: Since the side panels open and close, to access the controls, a gap is necessary at the mitre joint. The top trim piece has an adjustable securing bracket which enables the trim to be secured to the firebox shell. W415-0224 / D / 01.15.04 LOG PLACEMENT DOOR INSTALLATION LOG PLACEMENT DOOR INSTALLATION Positioning the logs improperly will cause flame impingement and carboning. PHAZERTM logs and glowing embers, exclusive to Continental Fireplaces, glow when exposed to direct flame and provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the glowing embers for a maximum glowing effect. Use only certified PHAZERTM logs available from your Continental / Wolf Steel Ltd. dealer. 1. Place the rear log (#1) onto the two log supports and against the air intake pipe. #1 FIGURE 12 2. Position logs #2 and #3 against the grate posts and line up the studs located on the burner with the holes on the bottom of the logs. Keep slightly back of the front row of ports. #3 #2 FIGURE 13 3. Fit the centre log (#4) into place behind log #3 and into the pocket provided on the back log. FIGURE 14 #4 FIGURE 15 GLOWING EMBERS 4. Tear the glowing embers into pieces and place along the front row of ports covering all of the burner area in front of the logs. Care should be taken to shred the embers into thin, small irregular pieces as only the exposed edges of the fibre hairs will glow. The ember material will only glow when exposed to direct flame; however, care should be taken to not block the burner ports. Blocked burner...

Otros modelos de este manual:
chimeneas - CDIZC - N (752.17 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría