|
Resumen del manual
The BTU Input for electronic models is shown in Table 3: Electronic Models with Fixed Rate Gas Valve Natural and Propane Gas Model Series Input Rate (BTU / HR) SSDV-3530 23,000 SSDV-4035 29,000 Table 3 Gas Pressure - All Models Gas Pressure - All Models Inlet Gas Supply Pressure (all models) Fuel # Minimum Maximum Natural Gas 5.0" WC (1.24 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 13.0" WC (3.23 kPa) Table 4 Manifold Gas Supply Pressure (millivolt models) Fuel # Low High Natural Gas (Lo) 2.2" WC (.55 kPa) (Hi) 3.5" WC (.87 kPa) Propane (Lo) 6.3" WC (1.57 kPa) (Hi) 10.0" WC (2.49 kPa) Table 5 Manifold Gas Supply Pressure (electronic models) Fuel # Maximum Manifold Pressure Natural Gas (Hi) 3.5" WC (.87 kPa) Propane (Hi) 10.0" WC (2.49 kPa) Table 6 Test gauge connections are provided on the front of the millivolt gas control valve, identified IN for the inlet and OUT for the manifold side. A 1/8" NPT Test gauge connection is provided at the inlet and outlet side of the electronic gas control valve. These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.5 kPa). Orifi ce Sizes - Sea Level to High Altitude (All Models): These appliances are tested and approved for installations at elevations of 0-4500 feet (0-1372 meters) above sea level using the standard burner orifice sizes (marked with an "*" in Table 7). At the time of installation, it must be determined if the appliance needs to be derated. Contact your local gas supplier for deration requirements for your area. Deration -At higher elevations, the amount of BTU fuel value delivered must be reduced by either using gas that has been derated by the gas company or by changing the burner orifice to a smaller size as regulated by the local authorities having jurisdiction and by the (USA) National Fuel Gas Code NFPA 54 / ANSI Z223.1 - latest edition or, in Canada, the CAN1-B149.1 and .2 codes - latest edition. Burner Orifi ce Sizes Elevation 0-4500 feet ( 0-1372 meters) Model Series Natural Gas drill size (inches) Propane Gas drill size (inches) SSDV-3530 2.3 mm (.090") * 37L70 • #54 (.055") * 99K79 • SSDV-4035 #36 (.1065") * 18L40 • #52 (.0635")* 37G00 • * Standard size installed at factory • Part /Cat. Number Table 7 Burn-in Period During the first few fires of this appliance there will be some odor due to the curing of the paint and burning off of lubricants used in the manufacturing process. Depending on your use, the burn-in period may take a few hours or a few days. KEEP YOUR HOUSE WELL VENTILATED DURING THE CURING PROCESS. THE ODOR AND HAZE EMITTED DURING THE CURING PROCESS CAN BE QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. If an optional blower is installed, Do not turn it on during the Burn-In period. A white film may develop on the glass front during the first few fires as part of the curing process. The glass should be kept clean during the first two weeks of use to prevent the fi lm from baking on (making it very difficult to remove). See Cleaning Glass on Page 6. Gas Controls / Control CompartmentAccess NOTE: The top louvered panel and the bottomlouvered control panel door remove and installthe same way as follows: The gas controls can be found behind the control compartment access door. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Removing Control Compartment Door: Open the door by gently liftint it upward until the hook catches on boths sides clear the locating slots. Then pull door out to remove. On millivolt systems, the piezo igniter, HI/LO flame adjustment knob, and pilot and main gas OFF/ON control knob are located below the glass panel enclosure. The gas valve for electronic systems is also located below the glass enclosure panel. See Figure 1. Reinstalling Control Compartment Door: To reinstall, insert the hook catches on each side of the door into the corresponding slots in the control compartment opening, then gently push forward and side down until it locks in place. Figure 1 OPENING CONTROL COMPARTMENT DOOR Control Valve Lower Control Compartment Door Lift the Lower Control Compartment Doorup and pull out to remove. Up Out Hook Catch Operation of millivolt and electronic gas control systems are different. Before lighting and operating your appliance determine if you have a millivolt or electronic appliance. Familiarize yourself with the gas control valve that your appliance uses. Refer to Figure 1 for access to the gas control valve. Millivolt Appliances -Appliances with Millivolt systems will be fitted with the gas control valve shown in Figures 4 or 5. Electronic Appliances - Appliances with electronic systems will be fitted with the electronic valve...
Otros modelos de este manual:chimeneas - DIRECT VENT SSDVR-3530CNE (1.77 mb)
chimeneas - DIRECT VENT SSDVR-4035CNE (1.77 mb)
chimeneas - DIRECT VENT SSDVR-4035CNM (1.77 mb)
chimeneas - DIRECT VENT SSDVT-3530CNE (1.77 mb)