Manual de usuario Superior, modelo CDST-CMN

Fabricar: Superior
Tamaño del archivo: 4.28 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Note: Secure Flexvent must be attached to Secure Flexterminations only. DO NOT substitute Secure Ventterminations or the Secure Vent adapter for Secure Flex components. The collars of Secure Flex terminations and adapters have a different diameter than that used with the Secure Vent pipe. Additionally, Secure Flexcomponents have an extended length center tube for use in attaching the flexible vent. E. Attach Flex Vent to Termination Secure Flex components can be purchased separately and attached to bulk lengths of Secure Flex flexible tubing cut to size at the job site. Secure the flexible vent to the Secure Flex terminations in the same manner (see Figure 47 )as it was attached to the adapter. Step 4. FIELD WIRING Step 4. FIELD WIRING A. Millivolt Wiring (See Figure 49 )– 1. Select any of the following optional controls: appliance-mounted (rocker switch) or wall-mounted switch, thermostat, or one of the optional remote control kits. If appliance- mounted ON/OFF control is selected mount it in the gas valve mounting bracket. 2. If wall-mounted ON/OFF control or thermostat is selected mount it in a convenient location on a wall near the fireplace. 3. Wire the control switch within the millivolt control circuit using the 15 feet of 2 conductor wire supplied with the unit. Caution: do not connect the optional wall switch to a 120V power supply. 4. Alternatively, the appliance may be operated without the use of the controls indicated in step 1, solely by manipulating the gas valve control knob. In order to use this method, twist the free ends of the two conductor wire (located in the bottom compartment of the unit) together as shown in Figure 49. Note:The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment of the unit. Figure 49 Millivolt Wiring Diagram If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C, 18 GA. wire. Thermopile THTP TH TP *TWIST WIRES “A” AND “B” TOGETHER TO OPERATE UNIT SOLELY BY MANIPULATING THE GAS VALVE CONTROL KNOB; OR CONNECT WIRES TO OPTIONAL UNIT-MOUNTED ON/OFFSWITCH OR WALL-MOUNTED ON/OFF SWITCH OR THERMOSTAT TO OPERATE UNIT. *UNIT-MOUNTED ON/OFF SWITCH (Accessory Option) OR WALL-MOUNTED ON/OFF SWITCH (Accessory Option) OR THERMOSTAT (Accessory Option) OR REMOTE CONTROL RECEIVER (Accessory Option) A B NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Note:The gas valve ON/OFF switch is shown in Figure 51, or 52 on page 23. It is integral with the gas valve and should be set to the ON position. 10. After wiring is complete, reinstall the outlet receptacle, junction box/outlet receptacle assembly; install the field-provided the metal junction box cover plate. Receptacle, Junction Box and Cover Plate Installation Figure 50 2. Open the control compartment access panel by actuating the spring-loaded magnetic catches securing the panel, gently depressing the outer top corners of the panel until the catches "pop" the panel free, allowing it to swing out and down to open. 3. Remove the junction box/outlet receptacle assembly by removing the securing screw at the front right corner of the unit. SeeFigure 50. (The left and right designations used here are reversed in CDCR applications.) 4. Remove the outlet receptacle from the junction box by removing the two securing screws. 5. Install a field-provided strain relief in the cabinet knockout opening for the protection of the power supply wires. 6. Connect the power supply wires to the receptacle as shown in Figure 51, or 52 on page 23. 7. Connect the ground supply wire to the green wire attached to the outlet receptacle's green ground screw. 8. Install a wall-mounted ON/OFF switch or thermostat (not supplied) in a convenient location near the fireplace. 9. Wire the wall-mounted ON/OFF switch or thermostat to the low voltage circuit as shown in Figure 51, or 52 on page 23. Note:The supplied 15 feet of 2 conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment of the unit. Step 5. WIRING - OPTIONAL FORCED AIR BLOWER KIT FBK-100, FBK-200 and FBK250 Kits (See Figure 51 for FBK-100, FBK-200 and Figure 52 on page 23 for FBK-250 wiring)An electrical receptacle is provided for the installation of the FBK-100, FBK-200 and FBK-250 forced air blower kits. Electrical power must be connected to this receptacle in order to operate these blowers. Install the blower kits according to the installation instructions provided with the kits. Figure 511. If any of the original wire as supplied must be replaced, it must be replaced with Type AWM 105°C – 18 GA. wire. 2. 120V, 60Hz – Less than 3 amps. BK Junction Box Transf. 120 V. 24 V Factory Wired Field Wired BL Electronic Wiring Diagram (Honeywell) Showing the Blower Wiring for the Optional FBK100 and FBK-200 Kits R W BL OPT BLOWER G W *OPTIONAL ACC...

Otros modelos de este manual:
chimeneas - CDCR-CEN (4.28 mb)
chimeneas - CDCL-CEP (4.28 mb)
chimeneas - CDCL-CEN (4.28 mb)
chimeneas - CDCL-CMN (4.28 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría