Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Marantz, modelo FP-43

Fabricar: Marantz
Tamaño del archivo: 109.32 kb
Nombre del archivo: 467b3d92-8db1-4e3a-b062-88fd82c6a648.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It is also possible to rotate the door assembly in both a clockwise and counter clockwise motion. In or Out Adjustment By loosening the (A) Phillips head screws, it is possible to move the door assembly towards or away from the fireplace. It is also possible to tilt the door assembly in or out at the top or bottom. Note: The door adjustment procedure will be difficult to control if either the (A) or (B) fasteners are loosened too much. Door Removal Should it become necessary to remove the door assemblies from the fireplace, always remove the five (5) Phillips head screws that attach the door hinge to the fireplace, identified as (A) in Figure 6. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. A B Door Adjust Door Adjust Figure 6 Care and Cleaning of Your Glass Doors Never clean the glass when the doors are hot. Do not use ammonia or ammonia based glass or household cleaner to clean the glass or the door frame. An ammonia based cleaner will damage the finish of the glass door. Clean the glass doors by wiping with a damp towel followed by a clean dry towel to remove streaks. Remove stubborn stains from the glass with a mild soap solution and a towel dampened with clean water. Dry with a clean dry towel. • The fire must always be confined within the boundaries of the fuel grate. • The fireplace screens must always be closed whenever the fireplace is being used. • Never slam the glass door since it could cause the glass to break. • Do not build excessively large or hot fires — scorching or discoloring of the plated brass trim may occur. • Extreme temperature changes can cause glass breakage — do not build a hot fire and close the glass doors if the doors are cold. • If the tempered glass pane becomes scratched or chipped, it creates a weakness in the glass which can cause the glass to break when heated. Replace the pane of glass by contacting your nearest dealer. CAUTION: GLASS AND METAL FRAMES GET HOT — ALWAYS USE HANDLES TO OPEN AND CLOSE THE DOORS. WARNING: BE AWARE THAT SAFETY GLASS IS UNPREDICTABLE WHEN HOT AND MAY BREAK, EXPELLING HOT GLASS INTO THE ROOM. ADVISE ALL FAMILY MEMBERS TO REMAIN WELL AWAY FROM THE FIREPLACE WHEN OPERATING WITH DOORS CLOSED TO AVOID ANY POSSIBLE PERSONAL INJURY. IMPORTANT: Plated polished brass glass doors may have a plastic covering over all brass pieces for protection during shipping and handling. The plastic covering should be removed before installation of the glass doors. Under the plastic covering is a protective lacquer coating which should not be removed. In some instances, if it is removed, irreversible damage to the brass finish could occur. Refer to the following for specific information on plated polished brass. IMPORTANT: The lacquer coating on the polished brass glass doors and trim pieces can be damaged or removed causing corrosion and/or tarnish. Do not remove the protective lacquer coating from plated polished doors and trim. To help protect the finish; use a non- acidic wax and avoid the over-spray of acidic/ alkali based glass cleaners on the brass pieces. Please understand that the heat of the fire will cause the protective lacquer finish to slightly change to a light caramel color. Do not be alarmed as this is a normal occurrence. COMBUSTION AIR A proper amount of combustion air is important for your fireplace. Fireplaces consume large amounts of oxygen. It is important to allow an adequate supply of air. If the fireplace is not equipped with an outside air kit, it may not obtain sufficient amounts of combustion air from inside the house or structure in which it is installed. Therefore, the fire may draw from an outside air source and pull air in through the chimney. This may cause smoke spillage into the room. Smoke spillage often occurs when a fire is first started, until the fireplace and the chimney has had the opportunity to “come up to temperature” and to begin to function normally. If smoke spillage problems persist, a window may be opened just a crack to allow the proper flow of combustion air to the fireplace. If your fireplace is equipped with an outside combustion air kit, keep it open at all times when fire is burning and close when fire is out to prevent cold air intrusion. Combustion Air Control The actuator for combustion air system is standard on all fireplaces but must not be operated if the complete system is not installed. See Figure 7 and refer to Figure 3. If you have reason to believe that you do not have a complete outside combustion system, contact your distributor to have your fireplace inspected for the presence of the complete system before you use the combustion air actuator. DO NOT assume that you have this system in place because you have an actuating lever present on your fireplace front face. WARNING: DO NOT OPERATE THE COMBUSTION AIR ACTUATOR UNLESS A COMPLETE OUTSIDE COMBUSTION AIR VENT SYSTEM HAS BEEN INSTALLED WITH YOUR FIREPLACE. The control lever for the combustion air system is located on the left side of the fireplace op...

Otros modelos de este manual:
chimeneas - FP-38 (109.32 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría