Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Desa, modelo (V)G36R

Fabricar: Desa
Tamaño del archivo: 1.28 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


4. An outside air kit is available with this fireplace (see Optional Outside Air Kit, page 6). MINIMUM CLEARANCE TO COMBUSTIBLES Back and sides of fireplace 1 1/2" min.* Front of fireplace 48" min. Floor** 0" min. Perpendicular wall to opening 12" min. Top spacers 0" min. Mantel clearance see Mantels, page 5 Chimney outer pipe surface 1" min. * Not required at nailing flanges ** See step 2 of Framing WARNING: Do not pack requiredairspaceswithinsulation or other materials. Minimum/Maximum Chimney Height The minimum height of chimney, measured from base of fireplace to flue gas outlet of termination, is 16 feet for straight flue or a flue with one elbow set. The maximum distance between elbows is 6 feet. For systems with two elbow sets, the minimum height is 22 feet. The maximum height of any system is 50 feet. This measurement includes fireplace, chimney sections and height of termination assembly at level of the flue gas outlet (see Figure 15, page 9). FRAMING 1. Frame opening for fireplace using dimensions shown in Figures 1 and 2. 2. If fireplace is to be installed directly on carpeting, tile (other than ceramic) or any combustible material other than wood flooring, fireplace must be installed on a metal or wood panel extending full width and depth of fireplace. 3. Set fireplace directly in front of this opening and slide unit back until nailing flanges touch side framing. 4. Check level of fireplace and shim with sheet metal if necessary. 5. Before securing fireplace to prepared framing, ember protector (provided) must be placed between hearth extension (not supplied) and under bottom front edge of fireplace to protect against glowing embers falling through. If fireplace is to be installed on a raised platform, a Z-type ember protector (not supplied) must be fabricated to fit your required platform height. The ember protector should extend under the fireplace a minimum of 1 1/2". The ember protector should be made of galvanized sheet metal (28 gauge minimum to prevent corrosion. 6. Using screws or nails, secure fireplace to framing through flanges located on sides of fireplace. 28.25" 58.125" 67.125" 45.25" Figure 1 - Framing Dimensions 86.5" 61" Maintain 11/2 " Clearance at Sides and Back of Fireplace 11/2" Clearance Not Required at Nailing Flanges Figure 2 - Corner Installation 116010-01E Fireplace insTallaTion Continued HEARTH ExTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of fireplace opening is required to protect combustible floor construction in front of fireplace. Fabricate a hearth extension using a material which meets the following specifications: a layer of noncombustible, inorganic material having a thermal conductivity of K=0.84 BTU IN/FT, HR. F (or less) at 1" thick. For example, if the material selected has a K factor of 0.25, such as glass fiber, the following formula would apply: 0.25 x 1.0" = 0.30" thickness required 0.84 Thermal conductivity "K" of materials can be obtained from the manufacturer or supplier of the noncombustible material. If the hearth extension is to be covered, use noncombustible material such as tile, slate, brick, concrete, metal, glass, marble, stone, etc. Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a noncombustible material (see Figure 3). WARNING:Hearthextension is to be installed only as shown in Figure 3. Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Ember Protector Hearth Extension MANTELS Amantel may be installed if desired (see Figure 4). Woodwork such as wood trims, mantels or any other combustible material projecting from the front face must not be placed within 12" of the fireplace opening. Combustible materials above 12" and projecting more than 1 1/2" from the fireplace must not be placed less than 15" from top opening of fireplace (NFPA STD 211, Sec. 7-3.3.3). Mantels or any other combustible material also may come up to side edge of black metal face of fireplace as long as projection from front face fall within the limit shown in Figure 4. 12 1/4" Ref. 15" Min. 12" Min. 11/2" Max. 3" Nom. 33° Combustible Material Safe Zone for Projection of Combustible Materials Fireplace Opening Upper Section of Fireplace 6" Ref. FIREBOX SAFE ZONE Top View of Fireplace 3" Max. 4.5" Min. to Perpendicular 7.75" 33° Combustible Fireplace Front Elevated Ember Protector Seal Gap Material Must Side Wall Not Overlap Figure 3 - Hearth Extension 12" Front Face Figure 4 - Mantel Clearances to Combustible Material 116010-01E 6 116010-01E Figure 6 - Lineal Gain LINEAL GAIN PART NO. DESCRIPTION GAIN Georgian Fireplace 66 1/2" 12-12DM 12-12HT Pipe Section 10 5/8" 18-12DM 18-12HT Pipe Section 16 5/8" 24-12DM 24-12HT Pipe Section 23 5/8" 36-12DM 36-12HT Pipe Section 34 5/8" 48-12DM 48-12HT Pipe Section 46 5/8" RLT-12D RLT-12HT Round Termination 7 3/4"* STL-12D Square Chas...

Otros modelos de este manual:
chimeneas - (V)G36 (1.28 mb)
chimeneas - (V)G36H (1.28 mb)
chimeneas - (V)G36HR (1.28 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría