Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Marquis, modelo DVR-38

Fabricar: Marquis
Tamaño del archivo: 767.54 kb
Nombre del archivo: dc7b657c-b1c1-4e95-b376-5f2e48080331.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


WHAT TO DO IF YOU SMELL GAS: * Do not try to light any appliance. * Do not touch any electrical switch; do not use any phone in your building. * Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. * If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency or the gas supplier. USERS’ INSTALLATION OPERATION and MAINTENANCE MANUAL This appliance may be installed in an after-market, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. *Conversion Kit Required for Propane Use Installer: Please leave this manual with the appliance owner for future reference 7116 Beatty Dr 200-0044 Mission, BC V2V 6B4 Canada MARCH 2005 Marquis 38 3 CONTENTS Page Introduction 4 General Information 5 Appliance Description and Dimensions 6 Framing Dimensions 7 Clearance to Combustibles 8 Possible Fireplace Locations 9 Venting Instructions 10 - 13 Gas Connections 14 Glass Door Instructions 15 Log Placement Instructions 16 Fan and Valve Diagrams 17 Initial Start Up 18 - 19 Maintenance 20 Troubleshooting 21 - 22 Servicing 23 - 26 Replacement Parts List 27 Warranty 28 Warranty Registration 29 Manufactured by Archgard Industries Ltd., British Columbia, Canada. Patents Pending Marquis 38 INTRODUCTION Thank you for purchasing the Marquis DV-38 Direct Vent Built-in Gas Fireplace. The Marquis DV-38 is one of the most advanced gas fireplaces on the market. It is designed using the latest technology and manufactured to the highest quality. Some of the many features are: * Realistic Fire The Marquis DV-38 has a glowing ember bed in front and soft flowing flames at the back. A realistic split log set complements the flames. . Solid Construction The Marquis DV-38 is constructed mainly of satin coated and galvanized steel for long life and durability. Please read the manual carefully prior to installation and operation of the appliance. Proper installation, operation and maintenance of the appliance will provide you with many years of enjoyment. CAUTION Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Children and adults should be alerted to the hazards of high surface temperature and stay away to avoid burns or clothing ignition. Young children should be carefully supervised when they are in the same room as the appliance. Clothing or other flammable material should not be placed on or near the appliance. Do not operate with cracked or broken glass. Be careful not to strike or slam the glass. Any safety screen or guard removed for servicing an appliance must be replaced prior to operating. Installation and Repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, et cetera. It is imperative that the control compartments, burners and circulating air passageways of the appliance are kept clean. Marquis 38 5 GENERAL INFORMATION APPLIANCE CERTIFICATION This appliance is listed by Warnock Hersey for use in both the United States and Canada. It is tested and certified to the following US and Canadian gas appliance standards. -ANSI Z21.50-1996 / CGA 2.22-M96, Vented Gas Fireplace and Heaters - CAN/CGA-2.17-M91, Gas-Fired Appliances for Use at High Altitudes. Please contact Archgard Industries Ltd. if you have any questions regarding the certification of this appliance. INSTALLATION CODES This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or Installation Code, CAN/CGA-B149, in Canada. Electrical connections and grounding must conform with local code, or current National Electrical code, ANSI/NFPA No. 70-1987, in the US and in Canada, the current Canadian Electrical Code, CSA C22.1. SPECIFICATIONS Natural Gas (NG) Propane (LP) Manifold Pressure 3.5 in. w.c. ( 0.9 kPa) 10.0 in. w.c. ( 2.5 kPa) Min. Supply Pressure for Purpose of Input Adjustment 4.5 in. w.c. (1.2 kPa) 11.0 in. w.c. (2.8 kPa) Orifice Size #48 DMS ( 1.93 mm dia.) #56 DMS ( 1.18 mm dia.) Nominal Input Rating 16,000 BTU/hr (4.6 kW) 16,000 BTU/hr ( 4.6 kW) Altitude 0 - 4,500 ft. (0 - 1372 m) 0 - 4,500 ft. (0 -1372 m) Primary Air Opening . in. (6 mm) . in. (13 mm) HIGH ALTITUDE INSTALLATION When installing this appliance beyond 4500 ft. (1372 m) above sea level, the appliance must be properly de-rated and installed according to local codes. In the absence of local codes, with the current National Fuel Gas Code,...

Otros modelos de este manual:
chimeneas - DVT-38 (767.54 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría