Iniciar sesión:
Votos - 4, Puntuación media: 4.5 ( )

Manual de usuario Stovax, modelo 8564

Fabricar: Stovax
Tamaño del archivo: 965.64 kb
Nombre del archivo: 77f121a7-e7bb-46c2-b2f8-bf419e7dd65b.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


2.2 If your appliance has already been upgraded to battery remote control, please refer to the instructions provided with the upgrade to operate the remote control. The following instructions work for either situation. 2 AR0914 2.3 Ensure that the left-hand control knob is pointing to off ( ). 2.4 Ensure that the right-hand control knob is pointing to off ( ). 2.5 Press in the right-hand control knob and, keeping he knob depressed, turn it anti-clockwise until a click is heard and the knob is pointing to pilot ( ). The pilot should now light. If the pilot does not light, release the knob and repeat the procedure until it does. 2.6 Keep the control knob pressed in for 10 seconds and then release it, the pilot should stay alight. If the pilot goes out, repeat the procedures until it remains lit. 2.7 If the pilot does not light after repeated attempts, contact the retailer or installer from whom the appliance was purchased. 2.8 Turn the right-hand control to point to main burner ( ). The appliance can now be controlled using the left-hand control knob. 2.9 Turn the left-hand control knob to point to low fire ( ), the main burner lights on low. The burner can now be controlled between low and high settings. Turn the control knob anticlockwise to increase the flame height and clockwise to decrease the flame height. THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS REACHED SUFFICIENT HEAT - TYPICALLY 10 TO 20 MINUTES. IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE, WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE APPLIANCE. 4 USER INSTRUCTIONS 3. TURNING THE STOVE OFF 3.1 To turn the stove off, locate the control valve, turn the left- hand control knob until it points to off ( ). The main burner goes out leaving the pilot burning. 3.2 To turn the pilot off, locate the control valve, turn the right- hand control knob until it points to off ( ), the pilot goes out. 4. UPGRADING YOUR STOVE 4.1 Your stove is fitted with a control valve that can easily be upgraded to battery powered remote control. This upgrade can be fitted by anyone capable of simple DIY jobs and requires no special training. There are two versions of this control which can be obtained through your local Gazco stockist. 4.2 STANDARD REMOTE CONTROL. This remote controls the gas appliance after the pilot has been lit. It can turn the main burner on and regulate it from low through to high and back again. It can turn the main burner off leaving the pilot burning GAZCO PART NUMBER 8455. 4.3 THERMOSTATIC AND TIMER REMOTE CONTROL. This remote controls the gas appliance after the pilot has been lit. In ‘MANUAL MODE’ it can be used to turn the main burner on and manually regulate it from low through to high and back again. It can also be used to turn the main burner leaving the pilot burning. In ‘AUTO MODE’ it will automatically regulate the room temperature to a pre-set temperature. In ‘TIMER MODE’ it will turn the fire on and off according to a pre-set programme and automatically regulate the room temperature during the two ON periods. GAZCO PART NUMBER 8456 5. CLEANING THE FIRE WARNING: DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL IT IS COLD. THE STOVE RETAINS ITS HEAT FOR A CONSIDERABLE TIME AFTER SHUTDOWN. NOTE: THE CAST IRON DOOR IS HEAVY, TAKE EXTREME CARE WHEN HANDLING. 5.1 Remove the door by undoing the four dome nuts using the tool supplied and place to one side. 5.2 Carefully remove the ceramic fuel bed components and place to one side taking care to protect floor coverings etc, PLEASE HANDLE WITH CARE. 5.3 The coals should not require cleaning. Do not use a vacuum cleaner or brush to clean the coals, any large pieces of debris can be removed by hand. 5.4 Ensure any debris is removed from the burner ports. 5.5 Replace the ceramics by referring to section 6. 5.6 Use a damp cloth to clean the outer casing of the appliance. 5.7 The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application. Advice on Handling and disposal of fire ceramics Protective clothing is not required when handling these articles, but we recommend you follow normal hygiene rules of not smoking, eating or drinking in the work area and always wash your hands before eating or drinking. To ensure that the release of RCF fibres are kept to a minimum, during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it. When servicing the appliance it is recommended that the replaced items are not broken up, but are sealed within heavy duty polythene bags and labelled as RCF waste. RCF waste is classed as stable, non-reactive hazardous waste and may be disposed of at a licensed landfill site. Excessive exposure to these materials may cause temporary irritation to eyes, skin and respiratory tract; wash hands thoroughly after handling the material. 6. FUEL BED ARRANGEMENT The major ceramic components can be fo...

Otros modelos de este manual:
chimeneas - 8568 (965.64 kb)
chimeneas - 8574 (965.64 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría