Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario Bunn, modelo CDS-2

Fabricar: Bunn
Tamaño del archivo: 1.51 mb
Nombre del archivo: 29793.0000.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


15. Slip the mixing chamber (1) onto the mixing chamber water inlet tube far enough so the mixing chamber (1) will seat inside the whipper chamber (3). 16. Install hopper assembly in the dispenser by sliding hopper firmly behind the retainer plates on the hopper support panel. 9 8 7 6 5 4 1 3 2 FIG. 7 MIXING/WHIPPER CHAMBER COMPONENTS P1895 1. Mixing Chamber 2. Dispense Tip 3. Whipper Chamber 4. O-Ring 5. Frother 6. Receptacle w/Seal 7. Nut 8. Slinger 9. Motor Assembly 29793 061599 SERVICE (cont.) WHIPPER MOTOR P1924 FIG. 8 WHIPPER MOTOR Location: The whipper motor is located on the back side of the whipper motor mounting panel. Test Procedure: 1. Disconnect the dispenser from the power source. 2. Disconnect the white/red and white/brown wires of the main wiring harness from the black leads of the whipper motor. 3. With the CDS hopper level lower than the probe, press and hold the SERVICE switch and check the voltage across the disconnected harness wires with a voltmeter. Connect the dispenser to the power source. The indication must be: a) 120 volts ac for 120 volt models. b) 230 volts ac for 230 volt CE models. 4. Disconnect the dispenser from the power source. If voltage is present as described, replace the motor. If voltage is not present as described, refer to the wiring diagrams and check the dispenser wiring harness. Removal and Replacement: 1. Disconnect the dispenser from the power source. 2. Open the dispenser door and remove the hopper assembly out the front of the dispenser. 3. Remove the four #8-32 screws securing the hopper support panel to the auger motor mounting panel and the whipper motor mounting panel. 4. Slowly lift the hopper support panel up and disconnect the red/black and green wires from the hopper switch. 5. Pull the mixing chamber out of the whipper chamber. 6. Twist the whipper chamber clockwise and pull it off the whipper chamber receptacle. 7. Pull the frother off the motor shaft. Notice the flat side on the shaft and the matching flat inside the frother. It is important that these two flats are lined up when reassembling. 8. Slide the receptacle with seal off of the motor shaft. NOTE: To remove the receptacle only, rotate clockwise until the receptacle clears the nuts and slide off of the motor shaft. 9. Slide the slinger off of the motor shaft. 10. Remove the two nuts securing the whipper chamber receptacle and whipper motor to the front panel. 11. Disconnect the black leads on the motor from the white/red and white/brown wires of the main wiring harness and remove the motor. 12. Install new motor on rear of front panel and secure with two nuts. Connect the black leads from the motor to the main wiring harness. Refer to Fig. 9 29793 011500 SERVICE (cont.) WHIPPER MOTOR (cont.) when reconnecting wires. 13. Slide the slinger onto the motor shaft flush against the front panel. 14. Wash whipper chamber components in a mild solution of dish detergent using a bristle brush. 15. Rinse thoroughly and allow to dry before reinstalling in the dispenser. 16. Slide whipper chamber receptacle with seal and O-ring onto the motor shaft. 17. Rotate the receptacle with seal counterclockwise until it snaps into place on the motor mounting nuts. 18. Push frother onto the motor shaft, making sure the flat in the frother lines up with the flat on the motor shaft. 19. Connect the red/black and green wires to the hopper switch, Fig.10 and install the hopper support panel using the four #8-32 screws. 20. Install whipper chamber on the whipper chamber receptacle by twisting counterclockwise until tabs on the whipper chamber lock with the tabs on the whipper chamber receptacle. Be sure dispense port is pointing down. 21. Install dispense tip into the bottom of the whipper chamber. 22. Slip the mixing chamber onto the mixing chamber water inlet tube far enough so the mixing chamber will seat inside the whipper chamber. 23. Install hopper assembly in the dispenser by sliding hopper assembly on the hopper support panel until the slot in the bottom rear of the hopper seats against the pin and retainer plates on the hopper support panel. GRN to Control Boad (J1-8) RED/BLK to Control Board (J1-10) P1904 FIG. 10 HOPPER SWITCH TERMINALS BLK WHI/RED to Control Board (J7-2) WHI/BRN to Control Board (J7-4) P1903 FIG. 9 WHIPPER MOTOR TERMINALS 29793 061599 SERVICE (cont.) CONTROL BOARD and LEVEL PROBE P1925 FIG. 11 CONTROL BOARD Location: The control board is located behind the rear panel, mounted on the back side of the hopper motor mounting panel. Test Procedure: Liquid Level Control 1. Disconnect the dispenser from the power source. 2. Disconnect the twelve pin connector (J1) from the control board. 3. Check the voltage across pins 2 & 3 of the twelve pin connector on the wiring harness with a voltmeter. Connect the dispenser to the power source and select the “ON” position of the main power switch. The indication must be 24 volts ac. 4. Select the “OFF” position of the main power switch and disconnect the dis...

Otros modelos de este manual:
Molinillo de café - CDS-3 (1.51 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría