Iniciar sesión:
Votos - 8, Puntuación media: 3.8 ( )

Manual de usuario Philips, modelo HD7810

Fabricar: Philips
Tamaño del archivo: 3.68 mb
Nombre del archivo:
Idioma del manual:ruplukenhusk
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:
Cafeteras - HD7810 (454.48 kb)
Cafeteras - HD7810 (472.2 kb)
Cafeteras - HD7810 (463.93 kb)
Cafeteras - HD7810 (2.54 mb)

Resumen del manual


, If you intend to make another cup of SENSEO® coffee later, just leave , the coffee machine switched on.The machine automatically switches itself off after 1 hour. Cleaning Never immerse the SENSEO® coffee machine in water. Never clean the machine by flushing it with the lid open. Always unplug the machine before you clean it. Clean the outside of the machine with a moist cloth. Remove the coffee spout. 1 2 3 You can disassemble the coffee spout for more thorough cleaning. , 4 Clean the coffee spout, the pod holders and the drip tray in hot water, if necessary with some washing-up liquid, or in the dishwasher. 5 Hold the cup tray in your hand while you clean it with hot water, if necessary with some washing-up liquid. You can also clean the cup tray in the dishwasher. To clean the cup tray, always remove it from the machine, as it might prove sharp when it is handled incorrectly.Always handle it carefully. EnglisH 13 6 Clean the pod holders in hot water, if necessary with some washing- up liquid, or in the dishwasher. Make sure the sieve in the centre of the pod holder is not clogged. If the sieve is clogged, unclog it by rinsing the pod holder under a running tap. If necessary, use a washing-up brush or a pin to unclog the sieve. 7 Clean the water reservoir in hot water, if necessary with some washing-up liquid. Note:You can remove the cover of the water reservoir to clean the inside thoroughly. Note: If you use a washing-up brush, be careful not to damage the valve in the bottom of the water reservoir. 8 9 Rinse the parts with fresh water after cleaning and put them back into the machine. Clean the water distribution disc with a moist cloth. Be careful when you do this. Make sure that the rubber sealing ring does not get stuck under the edge of the water distribution disc. If it does, the coffee machine starts to leak! Flushing If you have not used the coffee machine for three days, flush it with fresh water before you use it again. Flush the machine in the following way: 1 Fill the water reservoir with cold water up to the MaX indication and put it back onto the machine. 2 Put the 1-cup pod holder ° or the 2-cup pod holder °° in the machine without pod(s). 14 EnglisH 3 Put a bowl (with a capacity of at least 1500ml) under the coffee spout to collect the water. AB 4 Press the on/off button I and subsequently press the 1-cup button ° and the 2-cup button °° briefly at the same time. The machine fills itself with water from the water reservoir.This takes some time and you will probably not notice that this happens.After a while, the machine starts to flush and switches itself off after the flushing cycle. Descaling When to descale Descale the SENSEO® coffee machine frequently! Preferably descale 4 to 6 times a year, but at least once every 3 months. Descaling takes about 1 hour. Do not interrupt the descaling process. Why to descale Scale builds up inside the appliance during use. It is essential to descale the SENSEO® coffee machine at least every 3 months.Your reasons to descale: -It prolongs the life of your SENSEO® coffee machine -It ensures maximum cup volume -It ensures maximum coffee temperature -The machine produces less sound during brewing -It prevents malfunctioning If the descaling procedure is not performed correctly, scale residue remains behind in the machine.This causes scale to build up more quickly and may cause permanent and irreparable damage to the machine. Use the correct descaling agent Only citric acid-based descalers are suitable for descaling the SENSEO® machine.This type of descaler descales the appliance without damaging it. For the correct amount, see under ‘Descaling procedure’ below. Each descaling mixture can be used only once. After use, the descaling mixture is no longer active. We advise you to use the special SENSEO® Descaler (HD7006). Read the instructions on the package of the descaling agent. Never use a descaling agent based on mineral acids such as sulphuric acid, hydrochloric acid, sulphamic acid and acetic acid (e.g. vinegar).These descaling agents may damage your SENSEO® coffee machine. EnglisH 15 Descaling procedure 1 2 Mix 50 grams of citric acid with 1 litre of water in a measuring jug. Stir until the powder is completely dissolved. Fill the water reservoir up to the MAX indication with the descalermixture.Then put the water reservoir back into the coffee machine. Note: Not all SENSEO® machine types have a water reservoir with a capacity of 1 litre. If you have a SENSEO® machine with a smaller water reservoir, repeat steps 2 to 6 with the remainder of the mixture without filling the water reservoir up to the MAX indication. 3 Press on/off button I. The machine is ready for use when the indicator light lights up continuously. 4 Place the 1-cup holder ° with a used coffee pod in it in the coffee machine. Close the lid and make sure it is properly locked. Note:Always put a used coffee pod in the pod holder when you descale the machine.This pod serves as a ‘filter...

Otros modelos de este manual:
Cafeteras - 60 (3.68 mb)
Cafeteras - HD 7810/75 (3.68 mb)
Cafeteras - HD 7810/95 (3.68 mb)
Cafeteras - HD 7810/65 (3.68 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría