|
Resumen del manual
Water will begin flowing into the tank. When water stops flowing into the tank, initiate a second and a third brew cycle. During the third brew cycle the tank will fill to its capacity and the excess will flow from the sprayhead, out of the funnel, and into the dispenser. 5. When the flow of water from the funnel stops, place the heater switch at the rear of the brewer in the “ON” upper position and wait approximately twenty minutes for the water in the tank to heat to the proper temperature. Some water will drip from the funnel during this time; this is due to expansion and should not occur thereafter. 6. Empty the dispenser and initiate another brew cycle as directed: 6A. Model C Pour one pitcher of tap water into the screened area on top of the brewer. 6B. Models CT, CTF, CWT, CWTA, CWTB, CWTF, CWTFA, CWTFB, SINGLE CW & SINGLE CWF Place the "ON/OFF" switch in the "ON" upper position, and on models SINGLE CW and SINGLE CWF place the batch selector switch in the "1 GAL" position. Momentarily press and release the start switch. 7. Place the "ON/OFF" switch in the lower “OFF” position after water has stopped flowing from the funnel, and let the water in the tank reheat to the proper temperature. 8. Empty the dispenser; place the "ON/OFF" switch in the "ON" upper position, and momentarily press and release the start switch. Check the water volume in the dispenser after water has stopped flowing from the funnel. It should be 64 ounces for all models except SINGLE CW and SINGLE CWF should be 128 ounces. 9. Models SINGLE CW and SINGLE CWF only, place the batch selector switch in the "1/2 GAL" position, and momentarily press and release the start switch. Check the water volume in the dispenser after water has stopped flowing from the funnel. It should be 64 ounces. 10. If water volumes are not correct, adjust the brew timer as required. See Adjusting Brew Volumes. Allow the water to reheat. Start, and measure another brew cycle. 11. Repeat step 10 until correct water volume is achieved. NOTE: For all Twins, repeat steps 1 through 10 for the other side. 12. The brewer is now ready for use in accordance with the coffee brewing instructions. ADJUSTING BREW VOLUMES NOTE: Check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server or decanter are in place, prior to setting or modifying batch sizes. 1. Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board. If the brewer has a batch selector switch, position it to the size to be changed. 0 To increase a batch size, Press and hold the START or BREW switch until three clicks are heard. Release the switch (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory) and press it again one or more times. Each time 41721 080310 Page 10 the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved. To decrease a batch size, Press and release the START or BREW switch once for every two-second interval to be removed from the total brew time period; then immediately press and hold down the START or BREW switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the desired volume has been achieved. 2. Setting batch sizes. To set a batch volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board. Press and hold the START or BREW switch until three distinct clicks are heard (this will take approximately ten seconds), and then release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to “OFF”. The brewer remembers this volume and will continue to brew batches of this size until the volume setting procedure is repeated. Empty server(s), turn selector switch to positions that have yet to be set, and repeat batch setting procedure until all batch sizes are set. NOTE: When brewing coffee, batch volumes will decrease due to absorption by the coffee grounds. 3. Setting programming disable feature. If it becomes necessary to prevent anyone from changing brew times once programmed, you can set the SET/LOCK switch to the “LOCK” position. This will prevent any programming to be done. NOTE: If the clicks can not be heard, lightly grip the incoming water line to feel when the valve cycles on and off. THERMOSTAT In most locations the thermostat should be turned to the full clockwise postion (200° F) for opt...
Otros modelos de este manual:Accesorios para el ordenador - CT (734.58 kb)