28. Type regedit /s “c:\program
files\altiris\aclient\sidgen.reg” in the script window, and then
select the option that the script must run in Windows.
29. Click Next, then Next, and then Finish.
30. Select Add > Run Script in the upper right corner of the Job window.
31. If the thin client is using the
EWF write filter, type ewfmgr c: -enable in the script window, and
then select the option that the script must run in Windows.
FBWF write filter, type fbwfmgr /enable in the script window, and then
select the option that the script must run in Windows.
32. Click Next, then Next, and then Finish.
33. Select Add > Power Control in the upper right corner of the Job window.
34. Check the option buttons for Restart and Force Applications closed.
35. Click Next, and then Finish.
36. Drag-and-drop this newly created backup job to the selected machine. A
Schedule Computer Job window is displayed with the following three options:
Do Not Schedule
Run this Job Immediately
Schedule this job
37. Select an option, and then click OK.
Upon completing these steps, SIDGen will automatically execute after any future
Rapideploy Imaging Job. The program will execute after the Post Configuration Task
and will add an extra reboot to the imaging process.
Executing Altiris SIDGen Utility
You can execute the Altiris SIDGen utility in several different ways. The most
common execution allows the utility to run silently within a Deployment Solution
imaging job. If the SIDGen utility is present in the same folder as the Aclient on the
client, the utility automatically executes during the Post Configuration Task without
user interaction or knowledge. Use this method with Deployment Solution 6.1 SP1
Hotfix C or later versions, which resolve cleanup failures. Insure that post
configuration runs, either by itself or in combination with an image capture/deploy
job, only when the FBWF writer filter is not in use (because either no writer filter is
in use or the EWF is in use). The sample jobs section of the Altiris console can be
used to send out a disable FBWF job before running the image capture/deploy job
or running a post configuration job by itself. Be sure to re-enable the FBWF by
using the sample jobs or other means afterwards, if desired.
You can also execute SIDGen through a command line or by double-clicking the
icon anytime the user wishes to generate a unique SID.