Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario Fujitsu, modelo PRIMERGY BX600 S3

Fabricar: Fujitsu
Tamaño del archivo: 4.01 mb
Nombre del archivo: bx600s3-zbox-en.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


BX600 S3 Operating Manual Updating BX600 System Components Preparation for Use and Operation E Extract the firmware file to the root directory of the TFTP file system. For information on the image file names, see the readme file of the update package. E Start an Internet browser on the client server. Enter the IP address specified above in the address field. Enter the user name and password admin. The home page is displayed. E In the navigation bar choose Flash/File. I Only two operation code image files can be stored on the switch blade. If there are already two image files stored, you must remove at least one of them before updating the firmware. It is recommended that you remove the older file (i.e. the file with the lower number). E Expand the File Name list (red arrow) in the Remove Operation Code Image File section to check if there are already two image files stored on the switch blade. If so, select the older one in the File Name list and click Remove File. Figure 24: Removing an operation code image file E Enter TFTP Server IP Address, Source File Name and Destination File Name. 66 Operating Manual BX600 S3 Preparation for Use and Operation Updating BX600 System Components Figure 25: Transferring the new operation code image file E Click Transfer from Server. E Wait a few minutes until the update process is complete. Refresh the browser for viewing. E Select the new image file in the pop-up window (red arrow) and click Apply Changes. Figure 26: Selecting Start-Up Operation Code Image File E Select Reset in the navigation bar. I After resetting, the switch blade will reboot. However, all settings specified previously (IP address etc.) will be lost and must be reentered on the management console. E Repeat the firmware update procedure for each installed switch blade. BX600 S3 Operating Manual 6 Property and Data Protection The lockable rack door protects the server against unauthorized access. To protect your system and data internally against unauthorized access, you can use the BIOS Setup security functions. Further security options can also be set in the installed operating system. If you wish to do this, consult your network administrator or refer to the documentation for the corresponding operating system. 6.1 BIOS Setup Security Functions The Security menu in BIOS Setup offers various options for protecting data against unauthorized access. By combining these options, you can achieve optimum protection for the system. I A detailed description of the Security menu and how to assign passwords can be found in the manual for the BIOS Setup and on the ServerBooks CD (see also “Related Publications” on page 157). Preventing Unauthorized BIOS Setup Calls This protection mechanism can be activated by setting a supervisor password in the Security menu. In addition, the Press F2 for Setup message in the Security menu can be suppressed. This message is then no longer displayed while the server's startup routine is in progress. Preventing Unauthorized System Access This protection mechanism can be activated by setting a user password in the Security menu. Preventing Unauthorized Boot Process This protection mechanism can be activated by setting a password on boot in the Security menu. BX600 S3 Operating Manual Server Blades This chapter describes how to install and uninstall server blades and server blade dummy modules in the PRIMERGY BX600 S3 basic unit, and what you need to be aware of when doing this. The information necessary for installing and operating the various server blade models can be found in separate manuals (see “Related Publications” on page 157). When you install a server blade in the basic unit, an important factor is the height. Figure 27 shows a 2-way server blade, which occupies one slot in the basic unit. Figure 27: PRIMERGY BX620 S3/S4 2-way server blade BX600 S3 Operating Manual Server Blades The 4-way server blade is twice the height and occupies two slots (figure 28). Figure 28: PRIMERGY BX630 scalable server blade (4-way configuration 72 Operating Manual BX600 S3 Server Blades Fitting rules 7.1 Fitting rules On the front of the PRIMERGY BX600 S3 basic unit are ten slots for server blades (numbered 1 - 10 from left to right). 1 2 3 4 5 6 7 8 9 10 Figure 29: BX600 S3 basic unit with ten 2-way server blades All ten slots are connected to the infrastructure modules on the back of the BX600 S3 basic unit via the midplane of the BX600 S3 basic unit: – Ethernet switch blades orpass-thru blades – Fibre Channel switch blades orpass-thru blades – Management blades – KVM blade – Power supply units In a PRIMERGY BX600 S3 basic unit different models and configurations of server blades can be operated alongside each other. V CAUTION! Server blades connecting a second SCSI channel to the midplane are not for use in the PRIMERGY BX600 S3 basic unit. BX600 S3 Operating Manual Adding a Server Blade to the System Server Blades I Server blades with a PCI I/O controller should be fitted in the middle...

Otros modelos de este manual:
Computadoras - PRIMERGY BX600 S3 (4.01 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría