Manual de usuario Kenmore, modelo CS-HE9DKE
Fabricar: Kenmore
Tamaño del archivo: 8.3 mb
Nombre del archivo: s_he9_12dke.pdf
Idioma del manual:
El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere
Resumen del manual
Remote Control 2.2. Indoor Unit 2.3. Outdoor unit 3 Product Specifications 4 Dimensions 4.1. Indoor Unit / Remote Control 4.2. Outdoor Unit 5 Refrigeration Cycle Diagram 6 Block Diagram 7 Wiring Diagram 7.1. Indoor Unit Page Page 2 7.2. Outdoor Unit 153 8 Electronic Circuit Diagram 163 8.1. Indoor Unit / Remote Controller 164 8.2. Outdoor Unit 185 9 Operation Details 206 9.1. Basic Function 2010 9.2. Indoor Power Relay Control 2110 9.3. Room Temperature Control (Compressor Control) 2211 9.4. Airflow Direction Control 2312 9.5. Quiet operation (Cooling Mode / Cooling area of Dry 13Mode) 2614 9.6. Indoor Fan Control 2814 9.7. Powerful Operation 30 © 2005 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 9.8. Automatic Operation 31 9.9. Sleep Timer Operation 32 9.10. Timer Operation 32 9.11. Auto Restart Control 32 9.12. Ionizer Operation 33 9.13. Oxygen Enrich Operation 34 9.14. Deice Control 36 9.15. Protection Control 37 10 Operating Instructions 39 11 Installation Instructions 45 11.1. Safety Precautions 45 11.2. Indoor Unit 48 11.3. Outdoor Unit 52 12 Installation and Servicing Air Conditioner Using R410A 55 12.1. Outline 55 1 Features • •••• Product . .... Telecommunication Support. . .... Air Swing to adjust vertical or horizontal airflow louver. . .... Four modes of operation selection. . .... Air filter with function to reduce dust and smoke. . .... Supersonic air purifying device (Super Alleru-buster) operation. . .... Remote control unit holder. . .... Remote control self-illuminating button. . .... Ionizer control to provide fresh air effect by generating negative ion. . .... Powerful mode to achieve setting temperature quickly room. . .... Quiet mode to provide quiet operation (Lo: -3dB). . .... Oxygen mode to supply oxygen enrich air to indoor room. . .... 24-hour real-timer setting. . .... Long installation piping up to 15 meters. . .... Guard net provided in Outdoor unit • •••• Quality Improvement . .... Random auto restart after power failure for safety restart operation. . .... Blue Coated Condenser for high resistance to corrosion. • •••• Serviceability . .... Removable and washable front panel. . .... Breakdown self diagnosis function. • •••• Environmental Protection . .... Non-ozone depletion substances refrigerant (R410A). 12.2. Tools For Installing/Servicing Refrigerant Piping 56 12.3. Refrigerant Piping Work 60 12.4. Installation, Transferring, Servicing 63 13 Servicing Information 67 13.1. About Lead Solder (PbF) 67 13.2. Troubleshooting 68 13.3. Disassembly of Parts 72 14 Technical Data 81 14.1. Operation Characteristics 81 14.2. Sensible Capacity Chart 83 15 Exploded View and Replacement Parts List 84 15.1. Exploded View (Indoor Unit) 84 15.2. Replacement Parts List (Indoor Unit) 85 15.3. Exploded View (Outdoor Unit) 86 15.4. Replacement Parts List (Outdoor Unit) 87 2 CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 2 Functions 2.1. Remote Control 3 CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 2.2. Indoor Unit 4 CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 2.3. Outdoor unit 5 CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE 3 Product Specifications Unit CS-HE9DKE CU-HE9DKE Cooling Capacity kW kcal/h BTU/h 2.60 (0.60 -3.00) 2,240 (520 -2,580) 8,870 (2,050 -10,200) Heating Capacity kW kcal/h BTU/h 3.60 (0.60 -6.50) 3,100 (520 -5,590) 12,300 (2,050 -22,080) Moisture Removal l/h Pint/h 1.5 (3.2) Power Source Phase V Cycle Single 230/240 50 Airflow Method OUTLET INTAKE SIDE VIEW TOP VIEW Air Volume Indoor Air (Lo) m3/min (cfm) Cooling; 5.2 (180) Heating; 6.3 (220) — Indoor Air (Me) m3/min (cfm) Cooling; 7.9 (280) Heating; 8.8 (310) — Indoor Air (Hi) m3/min (cfm) Cooling; 10.5 (370) Heating; 11.5 (410) Cooling; 23.8 (840) Heating; 23.1 (820) Noise Level dB (A) Cooling; High 39, Low 26 Heating; High 40, Low 27 Cooling; 46 Heating; 47 Power level dB Cooling; High 50 Heating; High 51 Cooling; High 59 Heating; High 60 Electrical Data Input W Cooling; 510 (120 -700) Heating; 690 (115 -1,720) Running Current A Cooling; 2.6 Heating; 3.5 EER W/W (kcal/hw), BTU/hw Cooling; 5.10 (4.39), 17.4 COP W/W (kcal/hw), BTU/hw Heating; 5.22 (4.49), 17.8 Starting Current A 3.6 Piping Connection Port (Flare piping) inch inch G ; Half Union 3/8” L ; Half Union 1/4” G ; 3-way valve 3/8” L ; 2-way valve 1/4” Pipe Size (Flare piping) inch inch G (gas side) ; 3/8” L (liquid side) ; 1/4” G (gas side) ; 3/8” L (liquid side) ; 1/4” 6 CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE Unit CS-HE9DKE CU-HE9DKE Drain Hose Inner diameter mm 16 — Length m 0.65 — Power Cord Length Number of core-wire 1.8 m 3-core wires . 1.0 mm2 — — Dimensions Height inch (mm) 11 -23/32 (298) 21 -1/4 (540) Width inch (mm) 34 -8/32 (870) 30 -23/32 (780) Depth inch (mm) 7 -27/32 (199) 11 -3/8 (289) Net Weight lb (kg) 24 (11) 79 (36) Compressor Type — Involute scroll Motor Type — Brushless (4-poles) Rated Output W — 750 Air Circulation Ty...