Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Mitsubishi Electronics, modelo MSY-A24NA

Fabricar: Mitsubishi Electronics
Tamaño del archivo: 1.48 mb
Nombre del archivo: 6faf0055-7578-4a74-b28c-3ce128f846fe.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Each time the button is pressed, the operation mode is changed in sequence: (I FEEL...) > (COOL) > (DRY) > (FAN) Description of “AUTO RESTART FUNCTION” • These units are equipped with an auto restart function. When the main power is turned on, the air conditioner will start operation automatically in the same mode as the one set with the remote controller before the shutoff of the main power. • If the unit was set to off with the remote controller before the shutoff of the main power, it will remain stopped even after the main power is turned on. • If the unit was in the emergency operation before the shutoff of the main power, it will start operation, when main power comes on, in the same mode as the one set with the remote controller before the emergency operation. • If the unit is operated in “I FEEL…” mode before power failure, the operation mode (COOL or DRY) is not stored in the memory. When the main power is turned on, the unit decides the operation mode by the initial room temperature at restart and starts operation again. Details of operation According to the room temperature when the operation starts, the operation mode is automatically set to COOL, DRY. However, when operation is started again within 2 hours after it is stopped, the same operation mode before the operation is stopped is selected. The operation mode selected first is not changed even if the room temperature changes. If the operation mode does not match the room condition, select the appropriate operation mode by pressing the MODE button. Details of auto operation Room temperature when started Operation mode Target temperature (initial state) About 77°F or higher COOL About 75°F About 77°F or lower DRY — NOTE: COOL: When the room temperature is 4°F higher than the set temperature, the set temperature may not be changed since the air conditioner is operating to reach the target (set) temperature. In this case, please wait until the room temperature drops to within 4°F of the set temperature and then change the set temperature. Description of “I FEEL...” mode To select the COOL, DRY or FAN mode: 1 Press the ON/OFF button. 2 Select the operation mode by pressing the MODE button. Each time this button is pressed, the operation mode is changed in sequence: (I FEEL) > (COOL) > (DRY) > (FAN) To stop operation: Press the ON/OFF button. After the operation mode is set once, the operation starts in the same mode as the one set previously from the next time by simply pressing the ON/OFF button. MANUAL OPERATION (COOL, DRY, FAN) a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a a When the set temperature is to be changed: • Press the TOO WARM button to lower the temperature. One press lowers the temperature by about 1°F. • Press the TOO COOL button to raise the temperature. One press raises the temperature by about 1°F. In COOL operation • When the outside temperature is low, the fan of the outdoor unit turns on and off frequently or decreases the rotation speed to maintain sufficient cooling capacity. In DRY operation • The temperature control (temperature setting) cannot be done. • The room temperature is slightly lowered in this operation mode. The details of the display on the indoor unit are explained on page 6. If the air conditioner does not cool effectively… If the fan speed is set to Low or AUTO, sometimes the air conditioner may not cool the air effectively. In this case, change the fan speed to Med. or upper. Change the fan speed. Fan speed: Low or AUTO Fan speed: Med. or upper 7 1 2 3 4 5 AIR FLOW VELOCITY AND DIRECTION ADJUSTMENT AIR FLOW velocity and direction can be selected as required. To change the AIR FLOW velocity, press the FAN button. Each time the button is pressed, the fan speed is changed in sequence: (Low) > (Med.) > (High) > (AUTO) • Use the (High) notch to cool the room more. • If the operating sound of the air conditioner disturbs your sleep, use the (Low) notch. To change the AIR FLOW blowing direction vertically, press the VANE button. Each time the button is pressed, the angle of the horizontal vane is changed in sequence: (1) > (2) > (3) > (4) > (5) > (SWING) > (AUTO) SWING OPERATION Use the swing operation for the air flow to reach all corners of the room. Recommended horizontal vane range for more efficient air-conditioning Use the (AUTO) position usually. Use position (1) or (2) in the COOL or DRY mode when adjusting to your requirements. NOTE: • In the cooling operation, when the air conditioner is operated with setting the horizontal vane to (4) or (5) for 1 hour, the AIR FLOW direction is automatically set to horizontal to prevent condensed water from dropping. • Adjust the vertical AIR FLOW direction using the remote controller. Moving the horizontal vanes manually can cause trouble. COOL DRY Auto air flow direction control operation When the AUTO mode is selected with the VANE button, the position of the horizontal vane is automatically set to correspon...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría