Iniciar sesión:
Votos - 1, Puntuación media: 4 ( )

Manual de usuario Amcor, modelo ALD-12

Fabricar: Amcor
Tamaño del archivo: 215.77 kb
Nombre del archivo: e7deb615-1fb6-46f4-b504-f338c47cf28c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


..................................... 11 Cleaning the Filter ............................................................................................................ .......................................... 11 End of Season Storage.......................................................................................................... .................................... 11 Storing the Power Cord........................................................................................................ .................................... 11 TROUBLESHOOTING.............................................................................................................. 12 YOUR GUARANTEE................................................................................................................. 14 1 Specifications Drainage Specifications Drainage During the process of cooling, some water will be extracted from the air into the unit. Most of this water is used to cool the unit and make it run more efficiently. This is a feature not found in most Portable Air Conditioners. If the unit is operated in VERY HUMID air, water will collect in the container inside If the water container is full, the compressor will stop, but the fan will continue to circulate the air. The POWER indicator will blink to inform you to empty the internal container. To make the cooling function work again, please empty the water by one of the following methods: By the Draining into a Container Use a Shallow Container or Dish 1. Turn off the unit. 2. Position a flat container or dish under the drain hole. Do not allow the water to drip continuously into the container, as it might easily overflow. 3. Remove the drain knob & rubber plug from the drain hole. The condensed water will drain out automatically. 4. When the container is almost full, replace the rubber plug into the drain hole to stop the water. Empty the container. 5. Repeat steps 2, 3 & 4 until all the condensed water is emptied. 6. Once all the condensed water has been removed, replace the rubber plug into the drain hole firmly. The Full Water indicator should be off now. 7. Replace the drain knob. By Water Tube (Continuous Drainage) 1. Remove the drain knob and rubber plug and keep them for future use. 2. Connect a suitable water tube (of 3/4" internal diameter - supplied) to the water hole. The condensed water will drain out automatically. 3. If you want to extend the water tube you can connect it with another tube (outside diameter 3/4"). Special Caution for Heating Function! While using the heating function, please note: 1. Install the exhaust pipe securely in order to exhaust the cool air to the outside (please see page 6). 2. Use the continuous drainage option as described above. 3. The warmer the outside air the more heat will be pumped into the room. Working range for heat pump function is 41° F to 81° F. When used in room temperatures outside this range, the unit may not function properly. 4. While using the heating function during low temperatures, sometimes the heating will stop for a while in order to melt the internal frost. When this occurs, just wait for heating to resume. This is normal for compressor operated devices. Model Number ALD-12,000E ALD-12,000EH Cooling Capacity 12,000 BTU/hr 12,000 BTU/hr Heating Capacity (1)(2) N/A 12,000 BTU/hr Power Consumption 950W / 9A 950W / 9A Humidity Removal Capacity 55 Pts. / Day 55 Pts. / Day Recommended room size* 400 sq. ft. 400 sq. ft. Power Supply 120V / 60Hz / 1 Phase 120V / 60Hz / 1 Phase Compressor Rotary Rotary Refrigerant R-22 R-22 Fan Speed 2 2 Timer 1-12 hours 1-12 hours Thermostat 64° F - 90° F 64° F - 90° F Net Weight 65 lbs. 68 lbs. Dimensions 16"W x 17"D x 30"H 16"W x 17"D x 30"H Working Temperature Cooling: 64° F to 110° F Cooling: 64° F to 110° F Heating: 41° F to 81° F REMARKS: 1. The data may vary, please refer to the rating label on the back of the unit. 2. The above conditions are measured at: Cooling - Indoor: RT 81° F, RH 60% Heating - Indoor: RT 68° F, RH 60% * Uninsulated rooms such as sunrooms, garages, or attics should be less than 400 sq. ft. 10 3 Parts Operation - Electronic Control Models Parts Operation - Electronic Control Models Not available on all unitsFan Only Auto Room Temp. Not available on all units HighFan Power Temp. Up Temp. Down Fan Speed:High / Low On / OffTimerCool Set Temp. Low Fan Timer Control Panel Mode: AC or Fan Setting Mode/Function Press the MODE button to select the required working mode: Automatic, Cooling, Fan or Heating (Heating is only available for ALD-12,000EH). The green indicator illustrating your selected mode lights up. It is recommended to select Cooling or Heating mode and set your desired temperature, as the Auto mode has a preset temperature (please see below) that cannot be changed. The indicators of the functions in progress come on at the same time, e. g. Cool and Lo = Cooling mode with Low fan speed. Auto Mode When this mode is selected, the unit is ...

Otros modelos de este manual:
Los acondicionadores de aire - ALD-1 2 (215.77 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría