Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Hisense Group, modelo KFR 25GWE

Fabricar: Hisense Group
Tamaño del archivo: 211.31 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This will damage the internal components and cause an electric shock hazard. Clean the casing and grille of the indoor unit with a vacuum cleaner brush, or wipe them with a clean, soft cloth. If these parts are stained, use a clean cloth moistened with a mild liquid deteraent. When cleaning the grille, be careful not to force the vanes out of place. CAUTION I.Never use solvents, or harsh chemicals when cleaning the indoor unit. Do not wipe the plastic casing using very hot water. 2.Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts. 3.The internal coil and other components of the outdoor unit must be cleaned every year.Consult your dealer or service center. •16- Care and Cleaning (continued) Anti-Mold Filter How to remove the anti-mold filter Anti-Mold Filter Cleaning How to replace the anti-mold filter Air Clean Filter (not provided) A How to install the air clean filter WARNING The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. 1.Grasp both ends of the air intake grille and pull it out and up. 2.Push the anti-mold filter up slightly, and then pull it down. Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, wash the filter in lukewarm, soapy water, rinse it in clean water, and dry it. 1.With the "mW (meaning FRONT) mark facing you, slide the anti-mold filter up into the unit and then lower the handle into the groove on the unit. 2.After installing the anit-mold filter, press the locations marked by the arrows ( ) and close the air intake grille. The air cleaning filter removes dust and dirt from the air, and reduces odors and somke from tobacco. This air clean filter cannot remove harmful gases or vapors nor ventilate air in the room. You must open doors or windows frequently when you use gas or oil heating appliances.Otherwise there is a risk of suffocation in extreme cases. The air clean filter needs to be installed behind the anti-mold filter. 1. Remove the anti-mold filter. 2. Install the air clean filter in the position shown in the diagram, with the "mW (meaning FRONT) symbol facing the front. 3. Reinstall the anti-mold fillter. Air clean filter •17- Tips for Energy Saving Do not Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. • Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. Do •Always try to keep the air filter clean. (Refer to "Care and Cleaning" .)A clogged filter will impair the performance of the unit. •To prevent conditioned air from escaping, keep windows, doors and any other openings closed. Troubleshooting If your air conditioner does not work properly first check the following points before requesting service. If it still does not work properly, contact your dealer or service center. Trouble Possible Cause Remedy Air conditioner does not run at all. 1.Power failure. 2.Leakage breaker tripped. 3.Line voltage is too low. 4.Operation button is OFF. 5.Batteries in remote control unit have run down. 1.Restore power. 2.Contact service center. 3.Consult your electrician or dealer. 4.Press the button again. 5.Replace batteries. OPERATING lamp flashes while air conditioner does not operate. Trouble in wiring system. Contact servicer center. Compressor runs but soon stops. Obstruction in front of condenser coil. Remove obstruction. Poor cooling (or heating) performance 1.Dirty or clogged air filter. 2.Heat source or many people in room. 3.Doors and/or windows are open. 4.Obstacle near air intake or air discharge port. 5.Thermostat is set too high for cooling(or too low for heating). 6.(Outdoor temperature is too low.) 7.(Defrosting system does not work.) 1.Clean air filter to improve airflow. 2.Eliminate heat source if possible. 3.Shut them to keep the heat (or cold) out. 4.Remove it to ensure good airflow. 5.Set the temperature lower.(or higher) 6.(Try to use a back-up heater.) 7.(Consult your dealer.) Clicking sound is heard from the air conditioner. In heating or cooling operation, some plastic parts may expand or shrink due to a sudden temperature change. In this event, a clicking sound may occur. This is normal, and the sound will soon disappear. OPERATING lamp lights but outdoor unit will not run. 1.The use of portable telephones near the air conditioner may cause disturbance to its normal operation. 2.Restart the air conditioner after turn off the power immediately. 1.Turn off the power then restart the air conditioner after 3 minute. 2.The unit will restart automatically after three minutes. •18- Schematic Diagram 1. Main specifications of the product Type KFR-33GWE KFR-28GWE KFR-25GWE KFR-2101GWE KFR-3201GWE Power source AC,230V/50Hz AC,230V/50Hz AC,230V/50Hz AC,230V/50Hz AC...

Otros modelos de este manual:
Los acondicionadores de aire - KFR 2101GWE (211.31 kb)
Los acondicionadores de aire - KFR 28GWE (211.31 kb)
Los acondicionadores de aire - KFR 3201GWE (211.31 kb)
Los acondicionadores de aire - KFR 33GWE (211.31 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría