Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Hisense Group, modelo KFR-3208GW

Fabricar: Hisense Group
Tamaño del archivo: 846.22 kb
Nombre del archivo: 44e55b69-2373-4192-9a06-914e9f32ff40.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Contact the local distributor or after-sales service for further information. A. Wiring Only qualified professionals should carry out wiring of the appliance. Disconnect the power supply before completion of wiring, piping or checking the appliance. Voltages generated by the appliance is fatal. Read the electrical schematic diagram and explanation before installation. Improper installation and earth connection may result in fatal injury. Connect the earth as required by local wiring regulations. Tightly fasten all the wiring connections to prevent overheating or fire. Special power source, switches and sockets are required for the power supply of the appliance. Electric meter capacity must be larger than or equivalent to 16A. B. Transport Carefully move the outdoor unit. C. Installation ----When the appliance is mounted to the ceiling or the wall, Make sure that the ceiling or the wall is strong enough for the appliance. 1. Summery Read the operation manual before installation and keep this manual in a safe place. 1-1 Tools 1. Screwdriver 2. Phillips head screwdriver 3. Knife or wire stripper 4. Steel ruler 5. Spirit level 6. Hammer 7. Percussion drill 8. Tube cutter 9. Tubeflarer 10. Tubebender 11.Adjustable spanner 1-2 Attachment (see the packing list) 1-3 Parts Package Copper tubes, components and insulation materials for the outdoor unit. Make a wood or metal frame to support the appliance if necessary. ----When the appliance is mounted in a room, Properly insulate the tube of indoor unit, and make sure there is no water drops on the appliance or on the floor. ----When the appliance is installed on a damp or uneven area, Make a flat concrete base and place the base under the outdoor unit. ----When the appliance is installed in an area of strong winds. Using anchor bolts and metal frames to fix the properly covered outdoor unit. ----When the appliance (Model Heat Pump) is installed in an area of heavy snow. The outdoor unit must be installed in a position above the snow accumulation. D. Connection Use the shortest tubes possible Using a flaring method Smear some refrigeration oil between the flared surface and the connected tube. Fasten the nuts with a torque wrench to prevent leakage of refrigerant. Check for leakage before trial operation. E. Maintenance Disconnect the power before checking the electrical components and the circuits. Avoid contact with the moving parts of the appliance. Clear the site and make sure there is no installation debris left in the appliance. F. Other Keep the room well ventilated during installation. 1. Following table indicates that tubes should be cut with an additional length of 30cm-40cm, to reduce the vibration from the outdoor unit. Narrow tube Wide tube Outside Diameter Thickness Outside Diameter Thickness 6.35mm 0.8mm 9.52mm 0.8mm 2. The insulation materials for the copper tubes should conform to the required length and the wall thickness should not be less than 8mm. 3. Insulated copper wires should be used for wiring and the specification should depend on the length. 1-5 Additional materials for installation 1. white tape 2. nails or clips (as required) 3. putty 4. refrigeration oil 5. clips for fixing refrigerant tubes 1-4 Type of the copper tube and insulation materials 19 Appendix: Installation Appendix: Installation 2. Location 2-1 Indoor unit WARNING: Maintain the required space around the appliance to prevent overheat. The area for installation of the appliance should not be in an area with the following: Direct sunlight Heat resource Inflammable gas Thick oil fog The appliance should be installed in an area, Where the inside space can be evenly conditioned, or Which is strong enough for the appliance, or, Having the shortest distance for the copper tubes and water drain hose, and Having desired space around the appliance for maintenance and ventilation. Min. 5cm Min. 5cm Min. 5cm Tube arrangement L H Add. Refrigerant (g/m) Provided Tube(M) 15 7 25 4 L: Maximum length of the tube connecting the indoor unit and the outdoor unit. H: The height difference between the indoor unit and the outdoor unit. Tube length(L) Indoor unit Outdoor unit Height difference(H) 2-2 Outdoor unit The outdoor unit should be installed away from the following: Heat source and fan exhausting ; Director sunlight; 8 The outdoor unit should be installed in an area with, Cool temperature; Good ventilation; Desired space for air inlet, outlet and maintenance Top obstacle Air inlet Min. 5cm Min. 10cm Min. 40cm Valve side Min. 25cm Air outlet Air outlet Blockage Ground Min.10cm Air inlet 2 Strong base (10x40cm concrete or alike). The appliance should be placed not less than 10cm high. Air inlet Concrete or alike Anchor bolts(4) Min. 10cm About 10cmAbout 40cm If the length of the tube is between 7.5m to 15m(maximum length), an additional 25g/m of refrigerant should be added . Additional compressor oil must not be added. Fix the base with anchor bolts to reduce vibration and noise. CAUTION: The ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría