Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Danby, modelo DAC12507EE

Fabricar: Danby
Tamaño del archivo: 1.99 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


To operate the hand held remote control will require two “AAA” Alkaline batteries (included ). Batteries should be replaced when: a) No signal (beep) is heard when attempting to program the main unit. b) The main unit does not respond to a command issued by the remote control. Battery replacement: 1. Slide the rear cover on the remote in the direction of the arrow. Continue pulling (gently) until the cover separates completely from the unit. 2. Insert (2) batteries (AAA) following the same orientation (polarity) depicted inside the battery chamber.(+/-) 3. Re-install rear cover. 4. If the remote control will not be used for extended periods of time (vacations etc.), batteries should be removed. The remote operates within a range of 8 meters (26 ft.) from the receiver located inside the main unit. Any obstruction between the receiver and remote may cause signal interference, limiting the ability to program the main unit. 8 M ODE © 1 2 3 4 5 6 7 8 9 10 11 A B C D Electronic Display 12 Care and Maintenance Care and Maintenance End-of-Season Care 1. Operate the fan alone for half a day to dry out the When cleaning the air conditioner, be sure to inside of the unit. turn the POWER OFF and disconnect the power 2. Turn off power and remove plug from wall socket. cord from the electrical outlet. 1. DO NOT use gasoline, benzine, thinner or other chemicals on the air conditioner as these substances may cause damage to the paint finish and deformation of plastic parts. 2. Never attempt to pour water directly on unit as this will cause deterioration of the electrical insulation. Air Filter Removal: The air filter is located behind the air intake front grill. To remove the air filter, grasp the sides of the front grill and pull forward to open and access the filter. To reinstall the air filter, reverse the above procedures. The air filter may be vacuumed or washed by-hand in warm water. Dry thoroughly before installing. Cleaning Air Filter 1. Use a vacuum cleaner with soft brush attachment. 2. Wash the filter in lukewarm water below 40°C (104°F): To get better results, wash with soapy water or a neutral cleaning agent. 3. Rinse the filter with clean water and dry thoroughly before re-installing. IMPORTANT DO NOT forget to install the air filter. If the air conditioner is left to operate without the air filter, dust is not removed from the room air and may result in machine failure. When the air inlet grill and cabinet are dirty, wipe with lukewarm water (below 40°C / 104°F). Use of a mild detergent is recommended. 3. Clean filter. 4. Store (covered) air conditioner in a dry location. CAUTION When installing and/or removing the air conditionner from the window, ensure that caution is taken to prevent the unit from falling backward. It is recommended that installtion or removal of the airconditioner is done with assitance to prevent injury to persons or damage to the unit or property. 9 Troubleshooting Guide Frequently, a problem is minor and a service call may not be necessary, use this troubleshooting guide for a possible solution. If the unit continues to operate improperly, call Danby’s Toll Free Number 1-800-263-2629 for assistance, or call one of our service depots listed in the enclosed “Authorized Service Depot” listing provided with this unit. Difficulty Possible Cause Suggested Solution Air conditioner will not operate. No power to unit. Check connection of power cord to power source. Check fuse or circuit breaker. Inefficient or no cooling. Dirty air filter. Unit size inappropriate for application. Blocked air flow. Power interruption, settings changed too quickly, or compressor overload tripped. Clean or replace air filter. Check with dealer to determine proper unit capacity for application. Remove obstruction from grill or outdoor louvers. Turn the unit off and wait 5 minutes before attempting to re-start. Noisy unit. Loose parts. Inadequate support. Tighten loose parts. Provide additional support to unit. Odors. Formation of mold, mildew, or algae on wet surfaces. Clean unit thoroughly. Place algaecide tablet in base pan. Water dripping outside. Hot and humid weather. Condensation run-off is normal under these conditions. Water dripping inside. Unit is not properly angled to allow water to drain outside. Unit must be installed on an angle for proper condensation run-off. Check the unit and make any adjustments. Ice or frost build-up. Low outside temperature. Unit air filter is dirty. When outdoor temperature is approximately 65°F or below, frost may form when unit is in cooling mode. Switch unit to FAN (only) operation until frost melts. Remove and clean filter. NOTES: 1. If circuit breaker is tripped repeatedly, or fuse is blown more than...

Otros modelos de este manual:
Los acondicionadores de aire - dac10007ee (1.99 mb)
Los acondicionadores de aire - dac12077ee (1.99 mb)
Los acondicionadores de aire - DAC7077EE (1.99 mb)
Los acondicionadores de aire - DAC8007EE (1.99 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría