Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario Danby, modelo DAC5088M

Fabricar: Danby
Tamaño del archivo: 747 kb
Nombre del archivo: 9f814ab5-79bb-44b8-854d-e78de20f66a9.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Result: The Fan speed is adjusted. 4 To control the direction of the air flow, refer to page 7. Switching the Air Conditioner Off You can switch the air conditioner off whenever you want. To switch the unit off, simply press the Power Control selector to the "O" position. Power / Interrupteur r n 0 l 1 L J Adjusting the Air Flow Direction Horizontally Depending on the position of the unit in your room, you can adjust the orientation of the inner air flow blades on the unit. Adjust the air flow blades to the desired position by pushing them side to side. E-7> _[ ENGLISH Power Failure If a power failure occurs, the air conditioner is switched off. When the power comes back on, the air conditioner will start up automatically. Temperature and Humidity Ranges The following table indicates the temperature and humidityranges that the air conditioner can be used at. Mode IndoorTemperature OutdoorTemperature Indoor Humidity Cooling 21 °C to 32°C approx. 21°C to 43°C approx. 80%orless If the air conditioner is used at... Then... Higher temperatures The automatic protection feature may be triggered and the air conditionerwill stop. Lower temperatures A water leakage or some other malfunction may happen if the heat exchanger freezes. Higher humidity levels Water may condense on and drip from the surface of the unit if it is used for long periods. (e-8) Cleaning Your Air Conditioner Be sure to clean the air filter periodicaiiyto keep the air conditioner operating at optimum level. [||p** When cleaning the air conditioner, turn it off and pull out the power plug. 1 Open the front grille by pulling the tabs on both sides of the grille. Then lift it up slightly to open the front grille completely. 2 Grab the tabs on the filter and pull it up and out. 3 Remove all dust on the air filter with a vacuum cleaner or brush. 4 When you have finished, insert the air filter back into its original position. 5 Wipe the surface of the unit with a neutral detergent and then wipe it again with a dry cloth. (Be sure not to use benzene, solvent, or other chemical products). If you... Then- Wili not be using the ♦ Set the fan going for a few hours to thoroughly air conditioner for a dry the inside of the air conditioner, long period of time 4 Switch the air conditioner off and unplug it from the wall socket. ♦ Clean the filter and outer surfaces. Have not used the air Set the fan going for a few hours to thoroughly conditioner for a long dry the inside of the air conditioner, period of time 4 j ENGLISH Solving Common Problems Before contacting an authorized service center, perform the following simple checks. They may save you the time and expense ofan unnecessary call. Problem Explanation/Solution The air conditioner does not Check for a power failure. operate at all ♦ Check the voltage. (See the technical specifications). ♦ Check the power plug for disconnection. Check to see whether the Power Control selector is placed in the "O" position. (Set it to the desired position). ♦ Check to see whether the room temperature is too low. - Refer to page 8 for details about temperature condition. The air comes out smoothly, but cooling is not effective. Set the THERMOSTAT dial to the desired position. -When the number on the THERMOSTAT dial is too high, the room temperature may be too warm. Check to see whether there is an open window or other leakage of cool airtothe outside. - Close the window and fill the gap. Check to see whether there is any obstacle adversely affecting the flow of air inside and outside the room. - Remove the obstacle or change the position of the air conditioner. Check to see whether the air filter is clogged with dust or contaminated with foreign substances. -Clean the air filter. Check to see whether there is any direct sunlight facing the air conditioner. -Block the sunlight with a sunshade. Check to see whether there is any electric device generating heat. -Do not use the air conditioner together with any heating device. Odors are permeating the room during air conditioning ♦ Ventilate the room. (e-10| Technical Specifications Design and specifications are subject to change without notice. Model Power Supply DAC5088M 115V~,60Hz Important Safety Instructions The power cord supplied with this air conditioner contains a current leakage detection device designed to reduce the risk of fire. Please refer to the section "Power Supply Cord" for details. In the event the power supply cord is damaged, it cannot be repaired it must be replaced with a new cord from the Product Manufacturer. • Under no circumstances should this device be used to turn the air conditioner on or off. • The ‘RESET’ button must always be pushed in (engaged) for correct operation. • The power supply cord must be replaced if it fails to reset when the ‘TEST’ button is pushed in. • If the power supply cord is damaged, it cannot be repaired. It must be...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría