Manual de usuario Carrier, modelo 38AKS013-024

Fabricar: Carrier
Tamaño del archivo: 480.88 kb
Nombre del archivo: 38aks-3si.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


See Fig. 8 and unit label diagram for field-supplied wiring details. Route control wires through opening in unit end panel to connection in unit control box. 10 LEGEND LEGEND EQUIP GND — Equipment Ground NEC — National Electrical Code Factory Wiring Field Wiring C— Compressor Contactor HD — Heating Device Fig. 7 — Main Power Supply Wiring IFC — Indoor-Fan Contactor LLSV1 — Liquid Line Solenoid Valve 1 — Refrigerant Migration Control LLSV2 — Liquid Line Solenoid Valve 2 — Capacity Control R— Relay Factory Wiring Field Wiring NOTES: 1. Combination LLSV plus IFC va should not exceed 30 va. 2. Do not exceed 5 va (24 vac) per coil. 3. If va values shown in Notes 1 and 2 must be exceeded, use accessory relay transformer package 38AE900001 (60 Hz) or 38AD900003 (50 Hz and 380-3-60). Fig. 8 — Remote Thermostat Wiring Table 6A — Electrical Data (3 Ph/60 Hz) UNIT 38AKS UNIT COMPR FAN MOTORS (Single Phase) Model Volts MCA ICF MOCP (Fuse Only) RLA LRA Total Fans FLA (ea) Fan No. kWNameplate Supplied* Min Max 1 2 013 501 201 601 101 208-230 380 460 575 187 342 414 518 253 418 528 660 62.5 35.0 29.1 22.8 178 101 81 67 100 50 40 35 43.6 24.0 20.0 15.7 170 93 77 62 2 4.3 4.3 2.3 1.8 3.7 3.7 1.9 1.8 1.41 014 501 201 601 101 208-230 380 460 575 187 342 414 518 253 418 528 660 69.3 38.0 31.7 25.6 199 112 84 73 100 60 50 40 49.3 26.5 22.1 17.9 191 104 80 69 2 4.3 4.3 2.3 1.8 3.7 3.7 1.9 1.8 1.41 016 501 201 601 101 208-230 380 460 575 187 342 414 518 253 418 528 660 87.5 49.3 40.7 33.0 274 153 124 100 125 80 60 50 63.6 36.0 29.3 23.8 266 145 120 96 2 4.3 4.3 2.3 1.8 3.7 3.7 1.9 1.8 1.41 024 501 201 601 101 208-230 380 460 575 187 342 414 518 254 418 508 632 93.4 49.7 48.1 40.1 353 199 177 124 150 80 80 60 67.9 34.6 34.7 28.8 345 191 173 120 2 4.3 4.3 2.3 1.8 3.7 3.7 1.9 1.8 1.41 LEGEND FLA — Full Load Amps (Fan Motors) ICF — Maximum Instantaneous Current Flow during start-up (LRA of compressor plus total FLA of fan motors) kW — Total Fan Motor Input (kilowatts) LRA — Locked Rotor Amps MCA — Minimum Circuit Amps per NEC (U.S.A.), Section 430-24 MOCP — Maximum Overcurrent Protection (amps) RLA — Rated Load Amps (Compressor) *Units are suitable for use on electrical systems where voltage supplied to the unit terminals is not below or above the listed limits. NOTES: 1. The MCA and MOCP values are calculated in accordance with the National Electrical Code (NEC) article 440 (U.S.A. standard). 2. Motor RLA and LRA values are established in accordance with Underwriters’ Laboratories (UL) Standard 1995 (U.S.A. standard). 11 Table 6B — Electrical Data (3 Ph/50 Hz) UNIT 38AKS UNIT COMPR FAN MOTORS 230 v (Single Phase) Model Volts MCA ICF MOCP (Fuse Only) RLA LRA Total Fans FLA (ea) Fan No. kWNameplate Supplied* Min Max 1 2 013 803 903 230 400 198 342 264 457 47.5 31.4 134 80 75 50 32.9 20.0 128 74 2 2.9 3.5 1.20 014 803 903 230 400 198 342 264 457 51.0 34.0 149 89 75 50 35.7 22.1 143 83 2 2.9 3.5 1.20 016 803 903 230 400 198 342 264 457 66.9 43.0 206 121 100 60 47.9 29.3 200 115 2 2.9 3.5 1.20 024 803 303 903 230 346 400 198 311 342 254 380 440 91.8 51.5 50.2 213 121 179 150 80 80 67.9 33.3 34.6 207 115 173 2 2.9 3.5 1.20 LEGEND FLA — Full Load Amps (Fan Motors) ICF — Maximum Instantaneous Current Flow during start-up (LRA of compressor plus total FLA of fan motors) kW — Total Fan Motor Input (kilowatts) LRA — Locked Rotor Amps MCA — Minimum Circuit Amps per NEC (U.S.A.), Section 430-24 MOCP — Maximum Overcurrent Protection (amps) RLA — Rated Load Amps (Compressor) *Units are suitable for use on electrical systems where voltage supplied to the unit terminals is not below or above the listed limits. NOTES: 1. The MCA and MOCP values are calculated in accordance with the National Electrical Code (NEC) article 440 (U.S.A. standard). 2. Motor RLA and LRA values are established in accordance with Underwriters’ Laboratories (UL) Standard 1995 (U.S.A. standard). PRE-START-UP IMPORTANT: Before beginning Pre-Start-Up or Start-Up, review Start-Up Checklist at the back of this book. The Checklist assures proper start-up of a unit and provides a record of unit condition, application requirements, system information, and operation at initial start-up. Do not attempt to start the condensing unit, even momentarily, until the following steps have been completed. Compressor damage may result. System Check 1. Check all air handler(s) and other equipment auxiliary components. Consult the manufacturer’s instructions regarding any other equipment connected to the condensing unit. If unit has field-installed accessories, be sure all are properly installed and correctly wired. If used, airflow switch must be properly installed. 2. Backseat (open) compressor suction and discharge valves. Now close valves one turn to allow refrigerant pressure to reach test gages. 3. Open liquid line service valve. 4. Check tightness of all electrical connections. 5. Compressor oil level should be visible in sight glass. See Fig. 9. Adjust the oil level as required. Refer to Pre...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría