Iniciar sesión:
Votos - 5, Puntuación media: 3.8 ( )

Manual de usuario Carrier, modelo 30H

Fabricar: Carrier
Tamaño del archivo: 1.91 mb
Nombre del archivo: 30h-1si.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


3 COOLER DESCRIPTION.................4 COOLER PIPING........................4 Step 5 — Make Electrical Connections.....4 ELECTRICAL BOX, CONTROL SECTION . 5 ELECTRICAL BOX, POWER SECTION ... 5 START-UP AND SERVICE...................5 INITIAL CHECK.............................5 Check Refrigerant Charge....................6 LIQUID CHARGING METHOD...........6 Check Oil Charge...........................6 TO ADD OIL............................6 TO REMOVE OIL........................6 START-UP AND OPERATION CHECKS......6 Check Refrigerant Feed Components..........7 THERMOSTATIC EXPANSION VALVE ... 7 FILTER-DRIER..........................7 MOISTURE-LIQUID INDICATOR........7 LIQUID-LINE SERVICE VALVE..........7 PRESSURE RELIEF DEVICES............7 Page Check Compressor Protection Devices.........7 CIRCUIT BREAKER.....................7 DISCHARGE TEMPERATURE THERMOSTAT.........................7 CRANKCASE HEATER..................7 TIME GUARD® CONTROL...............7 FOUR FUNCTION TIMER ...............8 OIL PRESSURE SAFETY SWITCH (OPS) .8 Check Unit Safety Devices ...................8 SAFETY THERMOSTAT.................8 HIGH-PRESSURE SWITCH ..............9 LOW-PRESSURE SWITCH...............9 Check Capacity Control System...............9 DESCRIPTION ..........................9 4-STEP TEMPERATURE CONTROLLER .. 9 DESIGN SETPOINT ADJUSTMENT..... 10 CYLINDER UNLOADING SYSTEM...... 10 UNIT OPERATION ......................... 11 Control Power............................. 11 Control Sequence.......................... 11 Stoppage and Restart....................... 11 SERVICING THE COOLER.................11,12 Tube Plugging............................. 12 Retubing.................................. 12 Tightening Cooler Head Bolts................ 12 GASKET PREPARATION............... 12 BOLT TORQUES........................ 12 BOLT TIGHTENING SEQUENCE........ 13 TROUBLESHOOTING GUIDE..............14,15 INSTALLATION Step 1 — Inspect the Shipment Inspect the unit for damage or missing parts. If damage is detected, or if shipment is incomplete, file a claim immediately with the shipping company. Step 2 — Rig and Place the Unit RIGGING On each end of the cooler, a steel loop is provided for the preferred method of lifting the unit. Use spreader bars to keep cables away from the compressor enclosure and control box. If unit is to be moved by fork truck, use the following methods: 1. From the front or rear, lift under the cooler rails. Unit can be either on or off the skid. 2. When moving from the ends, leave the unit on the skid. Lift from under the skid. If unit is to be dragged or rolled into final position, leave it on the skid; apply force only to the skid, not the unit. When rolling, use a minimum of 3 rollers. PLACEMENT When the unit is in final position, remove the skid, level the unit with a spirit level and bolt to the floor or pad. These units are not suitable for unprotected outdoor use. Carrier recommends that these units be located in the basement or on the ground floor. However, if it is necessary to locate the unit on an upper floor, be sure the structure has been designed to support the weight. If necessary, add structural support to the floor. Also, be sure the surface for installation is level. Refer to Fig. 1 for space requirements and Table 1 for weight distribution. Only electrical power connections and water con-, nections for condensers and cooler are required for installation. Step 3 — Check Compressor Mounting and Connections — As shipped, compressor is held down by special self-locking bolts and plain lock washers. After unit is installed, remove the self- © Carrier Corporation 1979 Form 30H-1SI UNIT DIMENSIONS (ft-in.) ommsiON 040 050.060 LENGTH Sastc Unit A 8 1-7/16 8 1 With Cond. Manifolds A1 9 1-3/4 9 2-1/8 WIDTH B 2 11-3/8 2 11-3/8 HEIGHT c 6 7-3/16 6 7-3/16 BETWEEN MTG HOLES Length D 4 6-1/2 4 6-1/2 Width E 2 2 1 BETWEEN LIFT ANGLES F 6 1 M/2 6 11 DIMENSION IOC. CHILLED WATER CONN. InJet Outlet SPACE FOR COOlfft TUBE REMOVAL {Either End) LOC. COOLER DRAIN 040 1 - 6 0-11 7 - 6 1 - 2-1/4 050,060 1 - 11-1/2 1 - 5 3" MPT WATER OUTLET (CONDENSERS) (ACCESSORY)- SPACE REQUIRED FOR REMOVABLE OF COOLER TUBES \ (EITHER END) O'-iijDIA TUBE i BUNDLE (COOLER) LEFT SIDE VIEW - 13 DiA MTG HOLES (8) FRONT VIEW Fig. 1 — Unit Dimensions (30H050,060 shown} .f\. Tabie 1 — Weight Distribution (lb) UNIT 30H APPROXIMATE : OPERATING WT APPROXIMATE LOAD AT EACH MTG HOLE {A, B, C, D) 040 3930 983 050 4310 1078 060 4440 1110 LOCATION OF MOUNTING HOLES: I I f' 1 WATER--j-- D INLET i PLAN VIEW END - + - A 1 1 1 |----1__. 1 1 □D O ' FRONT 1 locking bolts one at a time and reassemble with flanged washers and neoprene snubbers as shown in Fig. 2. Special flanged washers and neoprene snubbers are shipped in a cloth bag tied to one of the compressor feet. Tighten all 4 bolts. Then loosen each until the flanged washer can be moved sidew...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría